![Goldline aqua trol Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/goldline/aqua-trol/aqua-trol_instruction-manual_2240915008.webp)
2019-2628
2019-10-10
CHEMICAL
IDEAL LEVELS
Free available
chlorine
1.0 – 3.0 ppm
pH
7.2 to 7.8
Total Alkalinity
100 – 120 ppm
Calcium
hardness
200 – 300 ppm
Salt
2700 – 3400 ppm
Cyanuric Acid
(Stabilizer)
30 100 ppm (Goldline recommends 80 ppm)
Metals
0 ppm (ideal)
Saturation
Index
-0.2 to 0.2 (0 Best)
Saturation index
The saturation index (Si) relates to the calcium and alkalinity in the water and is an indicator of
the pool water "balance". Your water is properly balanced if the Si is 0 ±.2. If the Si is below -0.2,
the water is corrosive and plaster pool walls will be dissolved into the water. If the Si is above
+0.2, scaling and staining will occur. Use the equation and chart below to determine the
saturation index.
Si = pH + Ti + Ci + Ai + 12.1
o
C
o
F
Ti
Calcium
Hardness
Ci
Total
Alkalinity
Ai
12
53
.3
16
60
.4
19
66
.5
24
76
.6
29
84
.7
34
94
.8
39
103
.9
75
100
125
150
200
250
300
400
600
800
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
75
100
125
150
200
250
300
400
600
800
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.8
2.9
How to use: Measure pool pH, temperature, calcium hardness, and total alkalinity. Use the chart
above to determine Ti, Ci, and Ai from your measurements. Insert values of pH, Ti, Ci and Ai into the
above equation. If Si equals .2 or more, scaling and staining may occur. If Si equals -.2 or less,
corrosion or irritation may occur.