Pro Logic Programming Flow Chart

North Kingstown, RI  02852  USA

092337A

Copyright © 2008 Goldine Controls

www.goldlinecontrols.com

Automation and Chlorination

Installation Manual

for model

PL-P-4

   

LD

C

G

LINE

ON TROLS 

   

LD

C

G

LINE

ON TROLS 

denotes conditional items

default menu

day and time

water temperature

air temperature

chlorinator setting

salt level

reason pump is running (not scheduled)

inspect cell

reason hi-speed is running (not scheduled)

countdown time remaining

heater control status

system manual off

check system error

filter speed

pH/ORP levels

settings menu

spa heater1 temperature

pool heater1 temperature

spa solar temperature

pool solar temperature

superchlorinate

spa chlorinator setting

pool chlorinator setting

spa high/low speed

pool high/low speed

day and time

backlit display light

beeper

teach wireless remote

wireless channel

maintenance menu

pH calibration wizard

clean probe wizard

timers menu

pool filter pump1 or hi-speed

pool filter pump2 or lo-speed

spa

lights

aux1

aux2

valve3

superchlorinate

diagnostic menu

chlorinator diagnostics

instant salt

pH/ORP levels

flow switch

cell temperature sensor

water sensor

air sensor

solar sensor

main software revision

display software revision

chemistry sense software revision

filter bridge/vsc software revision

RF base software revision

6 button spa side software revision

configuration menu

chlorinator

chemistry config. Wizard

pool/spa

filter

heater1

solar

lights

aux1

aux2

valve3

6 button spa side remote

remote menus

7-day or weekend/weekday timeclock

12 hour or 24 hour time format

ºF or ºC

reset to default

Содержание Pro Logic PL-P-4

Страница 1: ...www goldlinecontrols com Automation and Chlorination Installation Manual for model PL P 4 LD C G LINE ON TROLS...

Страница 2: ...nal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying the equipment One bondin...

Страница 3: ...al Remote Controls 7 Optional Base Station 8 Optional ValveActuators 8 3 Plumbing Pool Spa Configuration 9 Turbo Cell 10 Flow Switch 10 4 Electrical Main Service 11 Wiring Grounding and Bonding 11 Cir...

Страница 4: ...roofcover formountingonsideofProLogic Mounting hardware screws etc for mounting Pro Logic and remote display keypad Valves use standard Hayward Pentair Compool or Jandy valves Additionalvalveactuators...

Страница 5: ...raturesensors Remotedisplay keypad optional Valve actuators if applicable 3 Plumbing page 9 GeneralPoolEquipment Turbo Cell Flow Switch 4 ElectricalWiring page 11 Main service Groundingandbonding Circ...

Страница 6: ...ou are using the chlorinator features on the Pro Logic Control If you are NOT using the chlorinator it is recommended that you follow all of the other chemistry recommendations be sides salt Refer to...

Страница 7: ...100 45 110 160 50 73 120 170 55 77 130 180 59 81 140 190 64 86 150 200 68 90 93 42 107 48 120 55 133 61 147 213 67 98 160 227 73 104 173 240 79 110 187 253 85 117 200 267 91 123 2200 3000 2800 2400 32...

Страница 8: ...h x 893 Length x Width x Average Depth x 1000 POUNDS and Kg OF STABILIZER CYANURIC ACID NEEDED FOR 80 PPM Gallons and Liters of Pool Spa water Current Stabilizer Level ppm 0 ppm 20 ppm 60 ppm 30 ppm 4...

Страница 9: ...l O ring makes an adequate seal Do not overtighten 4 For maximum temperature accuracy cover the sensor and 3 6cm of pipe on either side with insulationandwhitepaint Air Sensor Mount the air sensor out...

Страница 10: ...sulated waterproof device which is intended for installation at the water s edge Theremotecontrolcomeswithanattached150 cableandistypicallyinstalledatthetile lineofthe spa wall or in the deck within a...

Страница 11: ...emote control is used To installthebasestation removetheknockoutontheupperleftsideoftheProLogicmaincontrolunit insert the base station and then tighten the nut from the inside Also refer to the Base S...

Страница 12: ...mps operate only when the filterpumpisonandthesystemisinthe poolonly operatingmode 6 The plumbing diagram above is intended to be used as a general guideline and is not a complete plumbingschematicfor...

Страница 13: ...for a watertight seal For systems with 1 plumbinguseadaptors providedbyinstaller Flow Switch supplied withAQL CLchlorination kit TheflowswitchmustbeplumbedinthesamesectionofplumbingastheTurboCell The...

Страница 14: ...ical panel to the Pro Logic ground bus bar Also ground each piece of high voltage 120 or 240VAC equipment that is connected to the Pro Logic control relays or circuit breakers The Pro Logic should als...

Страница 15: ...heProLogicrequires120VAC 2A powertooperatethecontrollogiccircuitsandthechlorinator This power should be connected to one of the circuit breakers WARNING 120VAC only permanent damage if connected to 24...

Страница 16: ...externaltransformer Forlightingsystemsthathavebothalightsource and color wheel connect the light source to the Lights relay and then connect the color wheel to one of theAUXoutputs Hayward Variable Sp...

Страница 17: ...red by a GFCB Low Voltage Wiring ValveActuators The Pro Logic can control up to three automatic valve actuators Two of the valve outputs are dedicated to the pool spa suction Valve2 and return Valve1...

Страница 18: ...raturerating for wires If no guidance is given use 105 C rated wire 3 Set any ON OFF switch on the heater to ON 4 Set the thermostat s on the heater to the maximum hottest setting Laars Heaters 1 Turn...

Страница 19: ...aterwillfirewheneverProLogicrequests whenProLogic Heater LEDisilluminated Pentair Purex MiniMax 1 Turn power off to heater 2 Removefactoryinstalledjumperfromthe ExtSwitch connector 3 Wire the Pro Logi...

Страница 20: ...L or SPA which then disables the remote control by the Pro Logic To prevent this Remove the heater touch pad connector P5 which will disable the touchpad STA RITE Heater 1 Turn power off to heater 2 R...

Страница 21: ...d VSC power connections if possible VSCPumpAddressSetting For proper communications a pump address must be set for each VSC used in the system For single pumpsystems theVSCaddressshouldbesetto001 When...

Страница 22: ...isplay keypads are installed Never connect more than 2 wires to any terminal block Two remotes can be wired back to the Pro Logic main unit or the second display keypad and third ifapplicable canbe da...

Страница 23: ...lineAqua Rite Chlorinator TheProLogiccancontroloneormoreGoldlineAquaRitechlorinatorswhenadditionalsanitizingcapacity is required A4 wire connection is used to communicate to theAqua Rite and can be wi...

Страница 24: ...gle between T CELL 5 and T CELL 15 Move to next menu item Move to next menu item Chlorinator Enabled Display Salt Chlor Config to view change Toggle between Display Salt default and Minerals Toggle be...

Страница 25: ...d Disabled default if Pool Only or Spa Only is selected Move to previous next configuration menu Filter Off Valve Change Enabled Toggle between Enabled and Disabled default if Pool and Spa is selected...

Страница 26: ...ter Cooldown mode Filter Config to view change Filter Pump 1 Speed Freeze Protect Enabled Lowest Speed 10 Highest Speed 100 Push to access pump options Rotates between 1 speed default 2 speed and vari...

Страница 27: ...erature to be used for freeze protection Temperature is adjustable from 33 F 42 F 1 C 6 C 38 F 3 C is default This threshold will be used for all outputs that have freeze protection enabled Heater1 Co...

Страница 28: ...enu item if Solar is enabled if Solar is enabled Allow Low Speed Disabled Toggle between Enabled and Disabled default Move to next menu item or previous next configuration menu if Solar is enabled and...

Страница 29: ...hts Function Although designated as the Lights output the function of the lights relay is similar to the aux1 and aux2 relays If pool lights are wired to the lights relay some options including Solar...

Страница 30: ...c will energize the lights relay IMPORTANT this only enables operation of the lights relay during freeze see the Filter Pump Config menu to enable freeze protection for the main circulation system NOT...

Страница 31: ...ntdown Timer Timeclock selected above and turn the aux1 off when filter pump is off first 3 minutes of filter pump operation allows the pump to prime and get water flowing when the pool spa suction re...

Страница 32: ...re threshold the Pro Logic will turn on the valve to allow circulation of the water IMPORTANT this only enables operation of the valve3 output during freeze see the Filter Pump Config menu to enable f...

Страница 33: ...ion parameters Move to previous next configuration menu config not reset Move to previous next menu config not reset Move to previous next configuration menu Use this function to erase all previous sy...

Страница 34: ...ng is set as high as possible usually 104 F 40 C Also note that some heat pumps actually have be set to the lowest possible temperature 3 Once the heater is running you can verify the heater cooldown...

Страница 35: ...itecap Drive North Kingstown RI 02852 for warranty service The costs incurred in removal and or reinstallation of the product are NOT covered under this warranty Some states do not allow limitations o...

Страница 36: ...pool high low speed day and time backlit display light beeper teach wireless remote wireless channel maintenance menu pH calibration wizard clean probe wizard timers menu pool filter pump1 or hi spee...