background image

 _ 9

UVL72

UVL150

UVL220

DIMENSIONS & WEIGHT

Product dimensions

479 x 76 x 200mm

479.3 x 76 x 400mm

TBA

Inner dimension

N/A

N/A

N/A

Packing dimensions 
(Carton)

N/A

N/A

N/A

Net weight

2.65 KG

3.8 KG

TBA

Gross Weight (Carton)

N/A

N/A

N/A

Dimensional drawing

OTHERS

Tube material

-

Housing Material

Aluminium alloy

Compliance

CE ETL FCC

Mounting

Surface mount or Wall mount

Accessory

Reflector

Power cord 

1.8m

Instructions for use

Usage:
1. Set the mechanical switch to the ON position, then press the key to start the luminaire

2. Leave the area immediately after the disinfection time is selected. The disinfection will start automatically after 2 minutes. The disinfection times available are 30 minutes, 60 
minutes and 120 minutes

3. Please turn off the mechanical switch after disinfection to avoid accidentally activating the luminaire again

Remote control:
1. Set the mechanical switch to the ON position, then press the button on the remote control to start the luminaire
2. Choose a disinfection time and the disinfection will begin after a 2  minute delay

Cautions

1. Ultraviolet disinfection lamp products emitting UV-C at 253.7nm must only be used in an environment with no living things present (humans, animals, plants)
Ultraviolet light may cause skin redness, itching, peeling, and eye conjunctive damage caused by electro-optical ophthalmitis. Never look directly at the lamp without suitable eye 
protection when it is powered on and emitting light. It is essential that all people and pets leave the room before the lamp is turned on and only re-enter the room after the lamp 
has been turned off/ has finished its disinfection cycle

2. Ultraviolet has a degrading effect on many materials including plastics, paper and cloth. Exposure to irradiation over long periods of time may cause the surface of the irradiated 
objects to change color and or become more brittle. Never use ultraviolet sterilization lamp products emitting direct irradiation on expensive clothing, ornaments, calligraphy, 
painting and other valuables

3. The surface of the lamp tube should be kept clean when using the UV disinfection lamp. It is recommended to clean the lamp tube regularly when not in use (usually every 2 
weeks). When cleaning, please use a soft clean cotton cloth with a small amount of alcohol to wipe the lamp tube surface, remove the dust and oil

4. A side effect of disinfection can be an abnormal smell, similar to that of the sun drying wet bedding, we recommend that spaces are well ventilated for 10-15 minutes following 
disinfection

5.UV lamps should be properly protected after disinfection and placed out of reach of children, in a safe place

6. Impact and strong vibration may cause the lamp tube to break. Should the lamp tube break, immediately turn off the power supply and dispose of the lamp, wearing protective 
gloves and according to your local toxic and harmful garbage rules. Should a lamp break, immediately open the windows for 10-15 minutes of ventilation

7. Never disinfect areas with inflammable or explosive items as you may otherwise cause burning or explosion

8. If the lamp tube needs to be replaced, replace only with the original brand of lamp tube and complete the operation according to the procedures in the user manual

INDUSTRIAL PRODUCTS

Содержание UV-BOX

Страница 1: ...DISINFECTION LAMPS ...

Страница 2: ......

Страница 3: ... spectral wavelength 253 7nm This belongs to the short wave UVC spectrum and is an efficient and better choice for disinfection HOW DOES UVC KILL BACTERIA AND VIRUS UVC in particular253 7nm destroys the molecular structure of DNA deoxyribonucleic acid and RNA ribonucleic acid of microbial bacteria and virus cells causing the death of growth cells and or regenerative cells thus achieving the effect...

Страница 4: ... UV C disinfection is a physical process no chemicals used no environmetal footprint left Goldensea UV installations are very affordable to install and operate The UV C disinfection results are related to the UV dose easy to measure and prove Goldensea UV disinfection systems are optimized for both mobile application and installations The UV C disinfection adds to your cleaning protocol and signif...

Страница 5: ...ll light up solid or flashing to provide a visual indication of the product s state REMOTE CONTROL THROUGH THE WALL IMPORTANT ACCESSORIES INCLUDED PROTECTION GLASSES WARNING SIGNS AUDIO ALARM A built in alarm will provide audible tones to alert users to the different important events and states the product is in LONGLIFE HIGH QUALITY QUARTZ GLASS TUBE Allows full transmission of ultraviolet light ...

Страница 6: ...sor buzzer alarm 3 options of disinfection time falling power off design Button start aroma volatilizes large capacity multi purpose 3 options of disinfection time Disinfection duration Disinfection area 15 mins 0 55m 30 mins 1m 60 mins 2m 15 mins 5m 30 mins 10m 60 mins 20m 5 mins 0 2m 10 mins 0 4m 15 mins 0 6m Disinfection height range No 0 4m 0 0 038m IP Rating IP20 SOFTWARE Child safety lock Ye...

Страница 7: ...s been turned off has finished its disinfection cycle 2 Ultraviolet has a degrading effect on many materials including plastics paper and cloth Exposure to irradiation over long periods of time may cause the surface of the irradiated objects to change color and or become more brittle Never use ultraviolet sterilization lamp products emitting direct irradiation on expensive clothing ornaments calli...

Страница 8: ...buzzer alarm 3 options of disinfection time 2 mins delay to light up mechanical switch and remote control remote control through the wall motion sensor buzzer alarm 3 options of disinfection time Disinfection duration Disinfection area 30 mins 20m 60 mins 40m 120 mins 80m 30 mins 40m 60 mins 80m 120 mins 160m 30 mins 60m 60 mins 120m 120 mins 240m Disinfection height range 0 4m IP Rating IP20 SOFT...

Страница 9: ...ned on and only re enter the room after the lamp has been turned off has finished its disinfection cycle 2 Ultraviolet has a degrading effect on many materials including plastics paper and cloth Exposure to irradiation over long periods of time may cause the surface of the irradiated objects to change color and or become more brittle Never use ultraviolet sterilization lamp products emitting direc...

Страница 10: ...he wall motion sensor buzzer alarm 3 options of disinfection time 3 mins delay to light up mechanical switch and remote control remote control through the wall radar sensor buzzer alarm 3 options of disinfection time falling power off design Disinfection duration Disinfection area 30 mins 20m 60 mins 40m 120 mins 80m 30 mins 240m 60 mins 480m 120 mins 960m 30 mins 60m 60 mins 120m 120 mins 240m Di...

Страница 11: ...t humans animals plants Ultraviolet light may cause skin redness itching peeling and eye conjunctive damage caused by electro optical ophthalmitis Never look directly at the lamp without suitable eye protection when it is powered on and emitting light It is essential that all people and pets leave the room before the lamp is turned on and only re enter the room after the lamp has been turned off h...

Страница 12: ...ptions of disinfection time can disinfect multiple items Disinfection duration Disinfection area 5mins 0 3m 10mins 0 6m 30mins 1 8m Disinfection height range No IP Rating IP20 SOFTWARE Child safety lock No Software upgrade No Lamp on delay No Motion detection Lamp immediately doused once opening the cabinet Alarm Buzzer No Tilt protection No Disinfection timing options 3 options CONTROL Remote con...

Страница 13: ...ctions for use 1 Open the cabinet door and put the items in the cabinet and close the door 2 Hold the power button to start the machine press the time button to select the disinfection time and press the power button to open the disinfection 3 When you choose the time you will hear a sharp warning sound Cautions 1 The disinfection function can only be activated after the cabinet door is closed 2 V...

Страница 14: ......

Отзывы: