5.   For In-Wall Mounting:

 

 

•  For optimum performance, loosely place two pieces of standard fi berglass insulation in the wall,

 

 

 

one just above the hole and one just below. An 8" x 10" piece should work well, R-12 for a 2x4 wall,

 

 

 

R-20 for a 2x6 wall.

 

 

•  Also place a half-think piece of fi berglass insulation cut to the height of the speaker in the wall right

   behind 

the 

mounting 

hole.

 

6.    For In-Ceiling Mounting:

 

 

•  For optimum performance, loosely place one piece of standard fi berglass insulation, cut to fi t the

 

 

 

joist size, above the speaker and extending about 15" or more beyond the speaker;

 

 

•  For taller joists, also place fi berglass insulation against the joists on either side of the mounting hole. 

 

 

 

7.  Pull the speaker wire out of the hole and connect the speaker as follows:

  • Your 

Invisa

®

 MPX speakers are equipped with a set of high-quality push spring connectors that can be 

 

 

 

used with bare wire. Make sure all wires are fi rmly fastened. Always use high quality speaker wire of the 

 

 

 

correct rating (see above) and suffi cient gauge for the distances you are running (see your dealer 

   for 

assistance).

  • Strip 

1

/

2

" (12 mm) of insulation from each of the two 

 

 

 

conductors to expose the metal, twist the strands 

 

 

 

of each into a single un-frayed strand.

  

 

•  Hold the speaker up to the cutout and connect the 

 

 

 

speaker cable. Proper polarity (or phase) is critical for 

 

 

 

proper stereo imaging and bass performance. Connect 

 

 

 

the red(+) terminal of your receiver or amplifi er to the 

 

 

 

red(+) terminal of the Invisa loudspeaker and the black(-) 

 

 

 

terminal of your receiver or amplifi er to the black(-) 

   terminal 

of 

the 

Invisa 

   loudspeaker 

(See 

Figure 

3). 

   Most 

speaker 

cables 

are 

 

 

 

either color coded or have 

   some 

indicator 

(ribbing 

or 

 

 

 

writing) on one of the 

 

 

 

conductors to help maintain this consistent polarity. 

 

 

 

It is essential that all speakers be connected in the 

 

 

 

same way (in phase) to its own channel of the amplifi er. 

 

 

 

If you experience a great lack of bass, it is likely that one 

 

 

 

speaker is out of phase (+ and – reversed) with the other.

 
 

 

•  Push down on the top of the speaker’s push terminal 

 

 

 

to reveal the wire hole in the post. Insert the wire  

 

 

 

into the hole and release your pressure on the terminal.

 

8

Turn your amplifi er/receiver OFF before performing any connection steps, in order to prevent 

accidental damage to your amplifi er.

If you plan to use multiple speakers per amplifi er channel. The minimum impedance of ONE Invisa 

in-wall/in-ceiling speaker is 4 ohms per channel.

Figure 3

Содержание Invisa MPX

Страница 1: ...Owner s Manual Invisa MultiPolar In Wall In Ceiling Loudspeaker Invisa MPX...

Страница 2: ...perfect integration in a wide variety of locations within your home To get the best performance possible and for a product that lasts a lifetime we strongly recommend that you follow the placement an...

Страница 3: ...B or between the 11 and 1 o clock settings with an analog control with bass treble and loudness controls not used otherwise rated power may be reached at even lower Volume settings Remember all amplif...

Страница 4: ...se differences your new Invisa MPX speakers have a high frequency EQ switch to increase or decrease the HF level to accommodate different room acoustics and placements Concrete floors and walls tend t...

Страница 5: ...in a 5 1 system Invisa speakers may be located on the side above or behind the listeners When used on the sides take care never to locate the speakers forward of the listeners A If the speakers are pl...

Страница 6: ...oustic perforations and muffle the sound It is not necessary to remove the backing cloth or scrim from the grille before painting Do not heat cure the finish Do not paint the grilles while attached to...

Страница 7: ...tallation Into Existing Walls or Ceilings For new construction pre drywall use our custom rough in brackets sold separately NOTE You must first install appropriate gauge and type speaker wires For bes...

Страница 8: ...ance Strip 1 2 12 mm of insulation from each of the two conductors to expose the metal twist the strands of each into a single un frayed strand Hold the speaker up to the cutout and connect the speake...

Страница 9: ...reely Figure 4 Make sure the rotating lock arms are positioned inwards Figure 5 so that your speaker fits into your cutout hole 9 Holding the speaker s front lip with your thumbs and index fingers car...

Страница 10: ...Speaker s High Frequency EQ Control HF EQ Switch We suggest starting with the HF EQ control Figure 8 in the center position in typical rooms with a balance of reflecting and absorbing surfaces If howe...

Страница 11: ...his is done through the use of a high pass filter implemented as part of the setup of the bass management system of your home theater receiver processor see below Setting Channel Levels and Bass Manag...

Страница 12: ...tances should products or parts be shipped to our offices or returned without contacting us first and obtaining return authorization GoldenEar Technology Offices P O Box 141 Stevenson Maryland 21153 P...

Страница 13: ...9 cm W Cutout 12 3 4 32 4 cm H x 6 1 4 15 9 cm W Weight 6 lbs 2 5 kg Frequency Response 25 Hz 35 kHz Efficiency 90 dB Nominal Impedance Compatible with 8 ohms Driver Complement Two 4 5 high definition...

Страница 14: ...GoldenEar Technology Invisa MPX Manual Invisa MPX Owner s Manual 14...

Страница 15: ...GoldenEar Technology Invisa MPX Manual 15...

Страница 16: ...ime freight collect This Warranty does not include service or parts to repair damage caused by accident misuse abuse negligence inadequate packing or shipping procedures commercial use voltage in exce...

Отзывы: