background image

9

REFRACTORY PANEL INSTALLATION

The Refractory Brick Panels should be carefully removed from shipping sleeve and positioned
upright against a stable object.
1. Look into fireplace opening and locate back

panel retaining clip positioned against rear
wall of fireplace. (Figure 9.1) Remove (2)
screws attaching clip to rear wall and set
clip and screws aside. Position rear panel
against rear wall and reattach clip with (2)
screws.

2. Locate left panel retaining clip and remove

(2) screws and set clip and screws aside.
Position left panel against left wall and
reattach clip with (2) screws.

3. Repeat Step 2 for right panel installation.

EXHAUST DIVERTER INSTALLATION

The Exhaust Diverter prevents exhaust gases from entering the room.
1. Locate screws attached to front side top of

interior firebox and remove. (Figure 9.2)

2. Position Exhaust Diverter into fireplace and

attach Diverter using screws removed
earlier. Diverter shold be positioned as
shown. (Figure 9.3)

Figure 9.1

Figure 9.2

Figure 9.3

Содержание EL GRANDE HD5030-TV

Страница 1: ...ualified installer service agency or the gas supplier The Flue Damper must be in the full open position when burning the gas logs This fireplace is to be burned only with the gas log set supplied with the fireplace Burning other items could cause a fire hazard or injury For best results Natural Gas pressure should be 7 to 12 W C and 11 W C for Propane Gas To simulate real wood burning the gas burn...

Страница 2: ...odes and Safety Standards 4 Piping and Gas Pressure Requirements 5 Installation Instructions 6 Log Placement 11 Operating Guidelines 13 Lighting Instructions 15 Trouble Shooting 17 Replacement Parts 19 2 INSIDE ROOM FLUSH MOUNT CHASE CORNER MOUNT 44 INSTALLATION OPTIONS Figure 2 1 ...

Страница 3: ...D5030 TV TOP VENT FIREPLACE INTERIOR VIEW Pan Burner Outside Air Control Knob Damper Control Lever Pilot Light Valve Access Panel 3 Gas Line Access Outside Air Port Outside Air Control Knob On Off Switch ...

Страница 4: ...D REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING BEDDING MATERIAL ETC IT IS IMPERATIVE THAT THE UNITS CONTROL COMPARTMENT BURNERS AND CIRCULATING AIR PASSAGE WAYS BE KEPT CLEAN TO PROVIDE ADEQUATE COMBUSTION AND VENTILA...

Страница 5: ...OPERATION OF THIS UNIT ON LP GAS WITHOUT AN APPROVED REGULATOR AT THE TANK WILL LEAD TO GAS LEAKS AT THE CONTROL VALVE WITH POSSIBLE FIRE OR EXPLOSION Include a manual shut off valve and union in the line so the control or heater may be disconnected for servicing Include a drip leg and a plugged 1 8 N P T tapping into the line also The tapping must be accessible for the test gauge connection immed...

Страница 6: ...it If the fireplace is to be installed on carpeting tile or other combustible material other than wood flooring the fireplace must be placed upon a metal or wood panel extend ing the full width and depth of the unit Fireplace framing can be built before or after the fireplace is set in place Framing should be positioned to accommodate wall covering and fireplace facing material The fireplace frami...

Страница 7: ... at least 36 above the highest point of the roof opening see below 3 The 10 Rule of Thumb is a guide for calculating chimney height that works under most conditions However many factors can cause the need for additional chimney height beyond what 10 Rule of Thumb would indicate Topographical factors can cause high pressure zones which prevent a chimney from drawing This can occur if the house is l...

Страница 8: ...nished wall and the fireplace surround Top and Sides can only be sealed with non combustible material Only non combustible material can be applied as facing to the fireplace surround Figure 8 2 Hearth Extension A Hearth Extension may be installed But it is not required for vented gas fireplaces 8 STUD FINISHED WALL NON COMBUSTIBLE SEAL JOINT MANTLE 12 MIN TOP OF OPENING Figure 8 2 CONTROL KNOB DUC...

Страница 9: ... and reattach clip with 2 screws 2 Locate left panel retaining clip and remove 2 screws and set clip and screws aside Position left panel against left wall and reattach clip with 2 screws 3 Repeat Step 2 for right panel installation EXHAUST DIVERTER INSTALLATION The Exhaust Diverter prevents exhaust gases from entering the room 1 Locate screws attached to front side top of interior firebox and rem...

Страница 10: ... Spread glowing embers over main burner pan and CEBB tube Note Be sure to create a gap between the main burner pan s glowing embers thus enhancing a front curl of flame from the main burner 4 Pour black rock around sides of pan for picture frame effect Note On L P models be careful not to pour black rock over brass air mixer attached to burner pan 5 Position log grate against rear wall of fireplac...

Страница 11: ...LOG PLACEMENT FOR MODEL HD5030 TV LOG SET STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 11 ...

Страница 12: ...STEP 7 STEP 8 FINAL ARRANGEMENT 12 ...

Страница 13: ...ELINES Upon completing the gas line connection WARNING CHILDREN AND ADULTS SHOULD a small amount of air will be in the lines BE ALERTED TO THE HAZARDS OF HIGH When first lighting the pilot light it will SURFACE TEMPERATURE AND SHOULD STAY take a few minutes for the lines to purge AWAY TO AVOID BURNS OR CLOTHING themselves of this air Once the purging IGNITION YOUNG CHILDREN SHOULD BE is complete t...

Страница 14: ...haracteristics is necessary CAUTION THE LOGS CAN GET VERY HOT HANDLE ONLY WHEN COOL MAINTENANCE INSTRUCTIONS IMPORTANT THE APPLIANCE AREA MUST BE KEPT CLEAR AND FREE FROM COMBUSTIBLE MATERIALS GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS Visually inspect pilot periodically Brush or blow away any dust or linen accumulations If pilot orifice is plugged disassembly may be required to remove any fo...

Страница 15: ...ss controls open valve access panel 3 Turn the control to the OFF position To do this you must turn the knob clockwise to the pilot position and then press in and continue turning clockwise to the OFF position 4 WAIT FIVE 5 MINUTES TO CLEAR OUT ANY GAS If you then smell gas STOP Follow B in the safety information above If you don t smell gas go to next step 5 The pilot does not require accessing f...

Страница 16: ... Telephone gas company and fire department Ask instructions Before hanging up give your name address and phone number DO NOT go back into building If your L P tank runs out of fuel turn off gas at the appliance After L P tank Is refilled appliance must be re lit according to manufacturer s instructions If the gas control has been exposed to WATER in any way DO NOT try to use it It must be replaced...

Страница 17: ...at electrode off pilot and trigger the red button again If pilot lights an improper gas air mixture caused the bad lighting and a longer purge period is recom mended If pilot will not light check gap at electrode and pilot should be 1 8 inch to have a strong spark If OK replace pilot C No gas or low gas 1 Check remote shut off pressure valves from fireplace Usually there is a valve near the firepl...

Страница 18: ...nd TP terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position pilot lit and ON OFF switch OFF Replace faulty generator if reading is below specified minimum B Defective valve 1 Connect the millivolt meter probes to the TH TP and TP terminals on the gas valve Turn knob to pilot position depress and light pilot light If meter reading is greater ...

Страница 19: ...lve knob to ON Place ON OFF switch to ON Check with millivolt meter at generator terminals Millivolt meter should read greater than 100 m v If the reading is OK and the burner does not come on replace the gas valve E Plugged burner orifice 1 Check burner orifice for stoppage and remove F Wall switch or wires 1 Follow corrective action in A 1 defective above check switch and wiring Replace where de...

Страница 20: ...mopile 26 HD 126 Volcanic Rock 10 HD 110 Pilot Assembly Bracket 27 HD 127 Temp Limit Switch 11 HD 111 Burner Orifice NAT 28 HD 128 Damper Switch 12 HD 112 Burner Orifice LP 29 HD 129 Silica Sand NAT 13 HD 113 Burner Pan Assembly 30 HD 130 Glowing Embers 14 HD 114 Log Grate Optional Parts Specify Finish 15 HD 115 Step 1 Left Log 31 HD 131 Left Glassdoor Bifold 16 HD 116 Step 1 Right Log 32 HD 132 R...

Страница 21: ... FIRST YEAR AFTER INSTALLA TION GOLDEN BLOUNT MAY DISCHARGE ITS ENTIRE WARRANTY LIABILITY BY REFUNDING THE PRICE OF THE PRODUCT PRODUCTS MADE BY OTHER MANUFACTURERS SOLD WITH THE FIREPLACE OR THEREAFTER ARE NOT COVERED BY THIS LIMITED WARRANTY THE USE OF OTHER UNAUTHORIZED COMPO NENTS WILL MAKE THIS WARRANTY NULL AND VOID THIS LIMITED WARRANTY WILL BE VOID IF THE APPLIANCE IS NOT INSTALLED BY A QU...

Отзывы: