background image

1

GENERAL INFORMATION

INSTALLER! PLEASE LEAVE WITH HOMEOWNER

INSTALLATION AND OPERATING INSTRUCTIONS

This appliance is to be burned only in an approved woodburning Fireplace with adequate chimney draft.
When burning, the chimney damper must be 

FULLY OPEN

.

This appliance must be installed in a fireplace which operates
properly when wood fires are burned.

 

For best results, natural gas pressure must be 7” to 10-1/2” water

column.

 

If used with glass fireplace doors, burn with doors in open position.

 

Do not burn wood or other items with this appliance.

Please Note: It is important that you read instructions before installing or operating this appliance

MANUFACTURED BY:

4301 WESTGROVE DRIVE

ADDISON, TX 75001

The installation, including provisions for combustion and
ventilation air, must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1-1988 and NFPA54-1988.

The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system when testing
at test pressures in excess of 1/2 psig.

The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of gas-supply system at test pressures
equal to or less than 1/2 psig. This is accomplished by closing
the gas supply line valve, which is required by NFPA 54,
section 5.54

The minimum inlet gas supply pressure for the
purpose of input adjustment is 7” WC for Natural Gas
and 11” WC for Propane Gas.

The maximum inlet gas supply pressure for this burner
is 10.5” for Natural Gas and 13” for Propane Gas.

This appliance is designed for use with Natural Gas unless clearly labeled for Propane (LP). Never use Propane Gas in an
appliance designed for Natural Gas or Natural Gas in an appliance designed for use of Propane Gas.

FOR YOUR SAFETY

If you smell gas:
1. Open Windows.
2. Don’t touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.

IMPORTANT INFORMATION

CHECK TO BE SURE APPLIANCE IS FOR PROPER GAS TYPE.

Содержание ALB24NAT

Страница 1: ...as supply piping system when testing at test pressures in excess of 1 2 psig The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of gas supply system at test pressures equal to or less than 1 2 psig This is accomplished by closing the gas supply line valve which is required by NFPA 54 section 5 54 The minimum i...

Страница 2: ...UM FIREBOX MINIMUM BTU HR WIDTH AT 7 DEEP REQUIRED FROM FRONT FIREBOX DEPTH ALB24NAT 26 20 22 500 ALB30NAT 32 20 25 250 ALB36NAT 38 22 34 000 ALB24NAT 26 22 20 500 ALB30LP 32 22 31 000 ALB36LP 38 22 37 750 The gas fittings supplied are for what the factory considers a normal installation Some installations may require a longer connector tube or other fittings available in most hardware stores 1 ...

Страница 3: ...optional decorative fireglass is used Spread the black volcanic cinders in front of and on sides of Linear Burner Figure 3 4 NOTE Optional Decorative Fireglass can also be used in place of black volcanic cinders Figure 3 5 YOU ARE NOW READY TO LIGHT THE BURNER BY TURNING THE FIREPLACE GAS VALVE ON AND USING A LONG MATCH OR BUTANE LOG LIGHTER LIGHT THE BURNER BY POSITIONING MATCH OR LIGHTER JUST OV...

Страница 4: ... control which has been under water E FIREPLACE DAMPER MUST BE FULLY OPENED FOR YOUR SAFETY READ BEFORE LIGHTING Pilot Burner Location Decorative Front Screw Remote Control Connector 1 Stop First read the safety information at the left 2 Remove two screws from sides of burner and take off decorative front to access control valve 3 Turn the control to the OFF position To do this you must turn the k...

Страница 5: ...SING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY READ BEFORE LIGHTING To Turn OFF Gas To Appliance 1 Turn off switch or remote 2 Remove Decorative Front 3 Turn control knob clockwise to PILOT 4 Depress control knob slightly and turn clockwise to OFF LIGHTING INSTRUCTIONS FOR MILLIVOLT CONTROL VALVE MODELS Decorative Front Screw On Off Switch Pilot Burner Location Gas Control Kn...

Страница 6: ... hand don t try to repair it Call a qualified service technician Force or attempted repair may result in fire or explosion D Do not use the appliance if any part has been under water Immediately call a qualified service technician to inspect the gas log set and to replace any part of the control system and any gas control system and any gas control which has been under water E FIREPLACE DAMPER MUS...

Отзывы: