Trouble Shooting your Dehumidifier
Problem
Cause
Solution
The Dehumidifier will not
turn on
The power is not connected
Ins ert plug into mains power
s upply a nd turn unit on
The Dehumidifier is not
extra cti ng water
The wa ter tank is full
Remove the water tank and
empty wa ter
The wa ter tank is not in its
correct position
Remove water tank and
repl ace it correct position
The a ir filter i s clogged
Cl ea n the air filter a s per
i ns tructions i n user manual
The temperature or relative
humi dity i n the room is too
l ow
It i s normal for the
Dehumidifier not to operate
i n l ow humidity or l ow
temperatures
The Dehumidifier operates,
but reduces the relative
humi dity i n the room by
s ma ll amounts
The room which the
Dehumidifier is operating i n
i s too large
Recommend using a
Dehumidifier with a larger
ca pa city
There a re too many s ources
of humi dity
Recommend using a
Dehumidifier with a larger
ca pa city
The room has too much
venti lation
Reduce the number of
venti lation sources (i .e. close
wi ndows, doors, etc.
SUPPORT AND TECHNICAL ADVICE
PROOF OF PURCHASE
To receive warranty retain receipt as proof of purchase.
Goldair
–
New Zealand
Monday
–
Friday 8am-5pm
Phone +64 (0)9 917 4000
Phone 0800 232 633
[email protected]
Goldair
–
Australia
Monday
–
Friday 8am-5pm
Phone +61 (0)3 9365 5100
Phone 1300 465 324
TECHNICAL SPECIFICATION
Model: GD330
Supply: 220-240VAC 50Hz
Wattage: 650W
Unit Capacity: 8L/day max (20°C/60%RH)
Tank Capacity: 2.0L