21
Suction Filter
It is essential to maintain all filters, and filter
screens, in good condition. Filter screens that
are not regularly cleaned can severely impede
the flow and thus affect delivery pressure.
If the screen is in any way damaged, it can
allow foreign material into the pumping
system which can result in damage to the
pump, lines, valves and nozzle tips. If the
screen is not properly fitted, it can allow air
into the pumping lines which will reduce the
performance of the pump. The filter screen
should be cleaned after every spraying
operation. The best way to clean the filter
screen is with a soft brush or compressed air
after washing the entire chemical residue from
the pump.
SAFETY SHUT-OFF VALVE
The safety shut off valve enables the filter bowl
to be removed while automatically shutting off
the supply line to the filter. As the filter bowl
is removed together with the bowl cap, the
valve plunger seats so as to seal off the filter
from the supply line. Replacing the filter bowl
unseats the valve plunger and thus opens the
supply line to the filter.
SUCTION FILTER CLEANING
WARNING:
Appropriate PPE must be worn
when cleaning filters.
1.
Ensure the pump is turned off.
2.
Carefully unscrew filter nut and remove
bowl and avoid contact with residual
chemical.
3. Remove screen and clean (with a soft
brush or compressed air).
4.
Check for damage to screen, bowl,body
and O-ring.
5.
Place screen back in position.
6. Make sure O-ring is in position for proper
seal.
7. Replace bowl and screw nut on. Do not
over-tighten nut.