background image

20

2

6

7

8

Pos. Part No.

Description

Qty.

1

-

Switch / Check valve and Upper Housing Kit (Replaces all 

previous switch designs)

1

2

GA5071575

Valve plate assembly

1

3

-

Diaphragm / Drive assembly

1

4

-

Motor

1

5

-

Complete Pump Head assembly (includes parts # 1,2,3) 

(Replaces all previous switch designs)

1

6

GA5071580

Diaphragm Assembly Kit

1

7

GA5071570

Housing Upper Male Threads

1

8

GA5071565

Pressure switch

1

Pump specifications: 

• 

12V 11.3 l/min 45 psi

 Repair kits include simple illustrated 

instructions allowing easy installation. 

To ensure that the correct kit is received the 

model number and all name plate data must 

be included with the order. 

Pump Service Parts - Shurflo 2088

Содержание Compact 300L

Страница 1: ...Compact 300L Operator s Parts Manual GA8700995 REV0 DEC 2018 ...

Страница 2: ...Assembly 25 Plumbing Schematic 27 Contact Goldacres 1 3 Morang Crescent Mitchell Park Vic 3355 P 03 5342 6399 F 03 5342 6308 info goldacres com au Disclaimer Any advice or recommendations given by Goldacres Goldacres dealers or employees is given in good faith and provided based on the best information available to us No liability or responsibility is accepted or implied as a result of any informa...

Страница 3: ...acres not only produce Australia s finest range of spraying equipment we also keenly value the unique relationship we enjoy with owners of our equipment We are pleased to welcome you as a Goldacres owner and look forward to making your spray applications as efficient as possible Please use this comprehensive resource to gain a full understanding of your equipment and don t hesitate to contact your...

Страница 4: ...anufacturer s specifications be checked and all instructions for use when transporting or towing be adhered to at all times Care should be taken when transferring liquid into the tank to ensure that the gross weight of the equipment does not exceed the carrying braking and or towing capacity of the vehicle to which the equipment is attached as specified by the vehicle manufacturer NOTE 1 LITRE WAT...

Страница 5: ...n transporting When draining fluids from the equipment use appropriate leak proof containers Do not use food or beverage containers as someone may consume the contents by mistake After reading the operator s manual if there is any thing that you do not understand please contact your Goldacres dealer Safe Chemical Use The safe use of Ag chemicals with this equipment is the responsibility of the own...

Страница 6: ...er equipment to the ATV spray tank This may exceed the ATV spray tank s designed capacity and function Reduce speed when operating the ATV spray tank when tank is loaded Allow for greater braking distances when the ATV spray tank is loaded To reduce possible ATV instability it is recommended the ATV be stationary if spot spraying on a slope or hill Ensure the ATV or vehicle complies with all relev...

Страница 7: ...e for your protection and it is the responsibility of the owner operator to replace damaged and or missing safety decals Regularly review safety decals with operators It is very important to ensure that all new machine components and replacement parts include current hazard identification decals Replacement safety decals can be ordered from all Goldacres dealers ...

Страница 8: ... housing Hydraulics Axle frame only Shockers and dampeners Wire cables Springs Drive chains Wheel bearings Failure caused by lack of lubrication not covered Warranty Exclusions Pump diaphragms Pump Seals Pump check valves Pump O rings Filters and filter screens Filter O rings Chemical Hoses Solenoid Diaphragms Hand Gun lance or wand seals and O rings Consumables chemicals fuels Items controlled by...

Страница 9: ...anship or materials used under normal use and service conditions The Warranty is not transferable The owner is responsible for the performance of regular maintenance and service as specified in the owner s operators manual applicable to the product Failure to follow regular maintenance as advised may invalidate the warranty The owner must provide the Goldacres Dealer with prompt written notice of ...

Страница 10: ...rchaser is entitled to at law which cannot be excluded by these terms and conditions and in all other cases b making good any defects by repairing the same or at Goldacres option by replacement within a period not exceeding either 1000 hours or twelve calendar months whichever comes first after the Goods have been dispatched provided that i the defects have arisen solely from faulty materials or w...

Страница 11: ...h ranking whether by act or omission 3 The Purchaser acknowledges that it has received value as at the date of first delivery of the Goods and has not agreed to postpone the time for attachment of the security interest as defined in the PPSA granted to Goldacres under these terms and conditions 4 The Purchaser will execute documents and do such further acts as may be required by Goldacres to regis...

Страница 12: ...ayer s performance The pump assembly is fitted with an inline suction strainer It is important that the strainer is cleaned out regularly Pump The pump is critical to any sprayer performance Correct operation and maintenance of the pump will ensure the sprayer is able to perform to its capabilities Make sure the pump wires are connected up to the correct terminals red to positive black to negative...

Страница 13: ...01 1100 1100 MATERIAL DRAWN BY NEALHARVEY MODEL EDITED BY 6 02 2018 THIS DRAWING REMAINS THE PROPERTY OF GOLDACRES TRADING PTY LTD AND IS SUBJECT OF COPYRIGHT SURFACE FINISH WEIGHT DRAWING EDITED BY 22 11 2018 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETRES DEBURR AND BREAK SHARP EDGES NEALHARVEY 22 11 2018 DRAWING CHECKED BY KG UNLESS OTHERWISE SPECIFIED 0 1 ANGULAR 0 50 0 0 0 5 0 00 0 2...

Страница 14: ...ated and that the conditions are right to start spraying Operators must wear the appropriate PPE 1 If wanting to spot spray only then turn off the ball valve in the boom line 2 Switch pump on 3 Allow pump to build pressure 4 It is recommended to set the regulator to maximum pressure 45 PSI when using the spray gun only Adjust the regulator if necessary 5 Engage the trigger on the spray gun to comm...

Страница 15: ... that there is adequate room for the boom to open Always ensure that the boom is adequately supported when transporting Boom Height The standard nozzle spacing on Goldacres booms is 500 mm For this spacing the optimum height the boom should be from the object to be sprayed with a 110 fan angle nozzle is 500 mm There will be adequate spray coverage if the nozzles are higher than this but this incre...

Страница 16: ...ime and reinserting them into another hole position The wings should be made parallel with the centre section Re tighten the adjuster bolts once complete Fold spring adjustment holes Boom wing angle stopper bolt Boom wing angle adjustment bolts Horizontal Angle Adjustment The boom horizontal angle is determined by the stopper bolt position against the stopper plate Loosen the locking nut on the st...

Страница 17: ...yre pressure Determining Correct Tyre Pressure Determine the maximum weight of the sprayer when loaded Allow for each tyre to carry half the maximum loaded weight of the sprayer this does not allow for any load on the tractor pull or cyclical loading which provides for a safety margin Determine what tyre size and ply is on the sprayer Determine what appropriate tyre pressure will provide the load ...

Страница 18: ...mpty 4 Protect hoses and electrical connections Problem Possible Cause Possible Remedy Pump not priming Valves damaged Restriction in suction line Restriction in delivery line Diaphragm damaged Check clean and or replace valve kit Check suction line Check delivery line Replace diaphragm Pulsating liquid flow Pump switching on and off due to pressure switch Pump sucking air Alter settings of the pr...

Страница 19: ...iaphragm if fluid is present at bottom drain holes Pump Will Not Shut Off Check Pressure switch equip Output line closed and no leaks For air trapped in outlet line or pump head For correct voltage to pump 10 Inlet Outlet valves for debris or swelling For loose drive assembly or pump head screws Pressure switch operation adjustment incorrect Refer to relevant pump manual for differential and press...

Страница 20: ...des parts 1 2 3 Replaces all previous switch designs 1 6 GA5071580 Diaphragm Assembly Kit 1 7 GA5071570 Housing Upper Male Threads 1 8 GA5071565 Pressure switch 1 Pump specifications 12V 11 3 l min 45 psi Repair kits include simple illustrated instructions allowing easy installation To ensure that the correct kit is received the model number and all name plate data must be included with the order ...

Страница 21: ...iner 50 mesh screen 1 2 male in female out 1 8 GA5005197 Swivel elbow 1 2 female nut x 1 2 male barb 1 9 GA5000469 Hose clamp 1 2 SS 3 10 GA5004081 Bolt M6 x 40 GR8 8 ZP 4 11 GA5004437 Washer 6mm Flat SS 8 12 GA5048115 Nut M6 Nyloc ZP 4 13 GA4508135 Plate Switch Mount for 12v Sprayers 2mm SS 1 14 GA5012667 Switch Toggle On Off Single pole single throw 1 9 8 7 5 2 3 4 1 13 14 6 NOTE USE LOCTITE 55 ...

Страница 22: ...or Model 30L 5A CPB22136 Inlet Body Brass For Model B30L 6 GA5077442 Stem Sub Assembly Brass and Type 302 SS 7 GA5077376 Cup Packing Buna N 7A GA5077377 Cup Packing Viton 8 GA5077421 Gasket Brass 9 GA5077420 Packing Screw Brass 10 GA5077588 Stem Nut SS 11 GA5077589 Trigger Stop Spring Type 302 SS 12 CP7622 302SS 6 Burr Type 302 SS 13 GA5077407 Roll Pin Type 420 SS 14 GA5077427 Roll Pin Type 420 SS...

Страница 23: ...p No Performance Liquid Pressure bar 1 5 2 3 4 A B A B A B A B GA8100370 Standard Capacity l min 0 79 2 61 0 98 3 18 1 14 3 67 1 40 4 54 Spray angle º 71 75 77 78 Max throw m 1 2 11 6 1 2 12 8 1 2 13 3 1 2 13 0 GA8100377 Capacity l min 0 98 3 14 1 21 3 79 1 40 4 54 1 70 5 30 Spray angle º 71 75 78 79 Max throw m 1 2 11 7 1 40 13 0 1 5 13 6 1 5 13 2 GA8100371 Capacity l min 1 17 3 71 1 40 4 54 1 63...

Страница 24: ...m 56487 3 10 GA5004919 Washer 8mm Spring SS 4 11 GA5003643 Washer 8mm Flat SS HD 4 12 GA5011263 Bolt M12 x 90 GR8 8 ZP 2 13 GA5000577 Washer 12mm Flat SS HD 4 14 GA5012461 Nut M12 Nyloc ZP 2 15 GA5011163 Bolt M10 x 70 GR8 8 ZP 2 16 GA5000117 Washer 10mm Flat SS HD 4 17 GA5000141 Nut M10 Nyloc ZP 2 18 GA5048380 Pin shaft locking 11mm 2 18 3 4 2 15 16 16 17 6 1 5 7 12 13 13 14 8 10 11 8 9 10 11 ITEM...

Страница 25: ...AWING REMAINS OF GOLDACRES TRADING SUBJECT OF COP UNLESS OTHERWISE DIMENSIONS ARE IN UNLESS OTHERWISE 0 1 ANG 0 0 0 5 0 00 0 25 F E D C B A 1 1 2 2 3 3 16 17 15 18 15 28 14 11 11 12 13 11 12 19 12 26 9 10 20 21 27 25 24 23 22 2 4 3 5 6 7 7 8 1 THIS DRAWING REMAINS THE PRO OF GOLDACRES TRADING PTY LTD SUBJECT OF COPYRIGHT UNLESS OTHERWISE SPEC DIMENSIONS ARE IN MILLIM UNLESS OTHERWISE SPEC 0 1 ANGU...

Страница 26: ...09 Hose barb Straight 3 4 male thread x 3 4 hose 2 16 GA5078427 Hose Connector 3 4 1 17 GA5018315 Valve Ball 20mm 3 4 male female Black Butterfly handle Brass 1 18 GA5000999 Hose Clamp 3 4 SS 2 19 GA5077710 Hose barb Elbow 90 degree 3 4 male thread x 1 2 hose 1 20 GA2000209 Hose Clear 12mm Sight tube Cut 520mm 1 21 GA2000211 Hose Pressure 12mm Black 250psi Hose reel to tee cut 550mm 1 22 GA2000211...

Страница 27: ...27 Plumbing Schematic ...

Страница 28: ...28 1 3 Morang Crescent Mitchell Park Vic 3355 P 03 5342 6399 F 03 5342 6308 info goldacres com au goldacres com au ...

Отзывы: