Troubleshooting
SYNTOM
DESCRIPTION
REASON
REMEDY
THE AMPLIFIER DOES NOT
WORK
The LED (15 is off
•
The power Chord is detached or
not correctly powered
•
Verify the AC power chord
connection.
.
•
Then Fuse is blown
•
Replace the fuse with one of
the same value.
THE AMPLIFIER SHUT DOWN
DURING PLAYING
•
The unit warms up too much and
the thermal switches inside turn it off
waiting to cool it down
•
Be sure the unit is necessarily
positioned in a airy place.
The PHONO (DISC) INPUT DOES
NOT WORK
•
The Phono MM & MC i san
optional feature
•
Be sure you have it installed on
the position wanted
THE AMPLIFIER HAS A LOW
LEVEL VOLUME WORKING
The amplifier needs to raise
up the volume knob over the
third quarter of the total run
to drive mid sensitivity
speakers
•
The Unit is designed to play also
high
sensitivity
speakers and the logarithmic
volume control features a soft raising that
enable the mid efficiency speakers work on
high knob position
•
There is no problem of
distortion even if the amplifiers drives the
speakers with volume knob closed to
maximum level