After installation all gas connections must be checked for leaks with a soap solution. When gas

connection is complete, wire the unit to the power source which will carry the current specified on

the unit's data plate.

TYPES OF GAS

The nameplate is marked at the factory to indicate the type of gas the appliance uses: either,

LP or propane for Liquified Petroleum Gas, or NAT or NG for Natural Gas. If necessary the

unit can be altered to change fuels, but we suggest a qualified service person do the work.

Please have your service person refer to the 

Maintenance and Repair section of this manual.

ALTITUDE RANGE

The factory has sized the burner orifices for an elevation up to 2000 feet above sea level. For

high altitude operation, please contact Gold Medal Engineering for the proper orifice size.

GAS PRESSURE

We have determined that optimum popping results occur when the gas pressure is adequate.

For LP gas, we recommend a pressure setting of 10 inches water column (6 oz. per square

inch); and, for Natural Gas, 4 inches water column (2 oz. per square inch). The pressure is

measured at the appliance while the main burner is ignited. A pressure regulator is supplied to

deliver the optimum pressure for both types of gas when the unit is changed from the original

factory specification. Follow the instructions in the 

Maintenance and Repair section. Adequate

gas requirements are maintained by properly sized piping. Be sure the piping is properly sized

to supply the needed pressure.

Do NOT use a match or flame to check for leaks – you may

cause a fire or explosion!

a

Содержание Mighty-Mite 2035BG

Страница 1: ...Mighty Mite Instruction Manual Model 2035BG Bottle Gas Model 2035DC DC Motor Bottle Gas Model 2035NG Natural Gas PartNo 74570 Revised June 1996 Cincinnati OH 45214 2089 USA ...

Страница 2: ...GAS SAFETY PRECAUTIONS ...

Страница 3: ...ng a location for your new Mighty Mite pay close attention to the installation clear ances The MINIMUM clearance for the sides is 6 inches the MINIMUM top back and frontal clearance is 30 inches This unit is certified for use on combustible surfaces The appliance and its individual shutoff valve must be disconnected from the gas supply piping during pressure testing of that system at pressures gre...

Страница 4: ...vation up to 2000 feet above sea level For high altitude operation please contact Gold Medal Engineering for the proper orifice size GAS PRESSURE We have determined that optimum popping results occur when the gas pressure is adequate For LP gas we recommend a pressure setting of 10 inches water column 6 oz per square inch and for Natural Gas 4 inches water column 2 oz per square inch The pressure ...

Страница 5: ...justment Cap should be turned to give more or less air A blue flame is desired for optimum heat TO POP POPCORN Turn the main burner on and put oil in the kettle You can let oil heat slightly before adding the popcorn and salt We recommend 14 ounces of popcorn 4 ounces of high quality coconut oil and Flavacol salt to give the best results A good measure of oil and Flavacol is the secret to top qual...

Страница 6: ... D 5019 4 Place the kettle in the dump position Remove the retainer screws Remove the burner Part No 74558 to expose the burner orifice hood Replace the main burner hood with the appropriate part number for the intended type of gas A Part 74629 61 for LP gas B Part 74630 53 for Natural Gas 5 Replace the pilot burner orifice with the appropriate part number for the intended type of gas Pilot Burner...

Страница 7: ...rt by checking it against the photos illustrations and or the parts list 2 When ordering please include part number part name and quantity desired 3 Please include your model name and machine serial number located on the machine nameplate with your order 4 Address all parts orders to Parts Department Gold Medal Products Co 10700 Medallion Drive Cincinnati Ohio 45241 4807 or place orders at 513 769...

Страница 8: ...Mighty Mite ALL MODELS 2035 6 BASO VALVE INFORMATION ...

Страница 9: ...Mighty Mite ALL MODELS 2035 7 BASO VALVE INFORMATION continued ...

Страница 10: ...Mighty Mite ALL MODELS 2035 8 KETTLE CROSS SECTION ASSEMBLY ...

Страница 11: ...per I D 1 16 74554 Thrust Washer Bronze 1 17 86540 Cotter Pin 1 18 74527 Agitator Assembly 1 19 74088 Seal Lid Hold Down Screw 1 20 74117 Flat Washer 8 1 21 74001 Screw Lid Hold Down 1 22 74574 Wing Nut 10 24 Nylon Insert 1 23 74520 Hex Head Bolt 20 x 1 24 47751 Set Screw 20 x 3 16 ADDITIONAL PARTS for Mighty Mite Items not shown 47145 A Scoop 47147 Measure One Cup 47148 Measure 14 Ounce 47660 Gol...

Страница 12: ...Mighty Mite ALL MODELS 2035 10 CABINET ASSEMBLY ...

Страница 13: ... LP 2 16 74120 Label Lighting Instruction 2 17 89045 Strain Relief T B 3302 2 18 74543 Mighty Mite Pedestal Weld 2 19 74116 Label Ground 2 20 74519 Front Cover Junction Box 2 21 47236 Bushing Snap SB 500 6 2 22 74538 Front Cover Plate 2 24a 74500 Wiring Diagram 120 230 Volt 2 24b 74511 Wiring Diagram 12 Volt 2 25 74119 Label Warning Disc Power 2 26 74551 Extension Shaft Assembly 2 27 74542 Mount P...

Страница 14: ...2 45 46566 Spring Pin 1 8 x 7 8 2 46 42070 Set Screw 10 24 x 2 47 47038 Kettle Motor 120V 60 Cycle 2 48 47028 Kettle Motor 230V 50 Cycle 2 49 74576 12 Volt DC Motor 2 50 47202 Switch Motor 120 230 Volt 2 51 47201 Switch On Off 12 VDC 2 52 74147 Screw 8 32 x Rd Hd Ph 2 53 74153 Screw 8 32 x 1 Hex Hd 2 54 74633 Ground Lug ...

Страница 15: ...Mighty Mite ALL MODELS 2035 13 ELECTRICAL SCHEMATIC ...

Страница 16: ...Mighty Mite ALL MODELS 2035 14 ELECTRICAL SCHEMATIC MODEL 2035DC ONLY ...

Страница 17: ... assume for us any other obligation or liability in connection with the sale of said GOLD MEDAL equipment or any part thereof The term Original Purchaser as used in this warranty shall be deemed to mean that person firm association or corporation who was billed by the GOLD MEDAL PRODUCTS COMPANY or their authorized distributor for the equipment THIS WARRANTY HAS NO EFFECT AND IS VOID UNLESS THE OR...

Отзывы: