MACHO POP
14
MODELS: 2553EX & 2554EX
Temperature Control
The Macho Pop has a electronic kettle control with 2 thermocouples, one
for control and one for limit. There are no mechanical thermostats in this
kettle.
There are (4) factory adjustments on the control:
Control temperature – do not adjust this one
Signal to dump – If you want the signal to dump to be a little sooner
or later you can adjust the potentiometer marked “kettle dump”.
CW is sooner, CCW is later.
The patented overshoot circuit is tuned for the kettle, do not adjust
this potentiometer.
The audible signal to dump has three options; full volume, half
volume, no sound (just the yellow light). Adjustments are by jumper
positions. This is set to full volume from the factory.
The control temperature is set
at 460F, DO NOT ADJUST
The overshoot is set at (-20%), full
CW position, DO NOT ADJUST
This is the “Kettle
Dump” adjustment, and
is factory set to signal
when the kettle is ready
to dump. Turning CW
will signal sooner, CCW
will signal later. If you
need to adjust, make
very small adjustments.
Remove this
jumper for no
sound
Remove this
jumper for lower
volume
It does not matter which TC
goes to A or B. It
does
matter
that the yellow leads go to the
positive terminals.
Hot Lead is
at L1,
Neutral lead
at L2.
a