  Reminder Duration 

With this option selected, the time period begins with a newly arrived message 

and is reset every time a new message is received. Once the time period expires, 

the pager does not emit any more reminder alerts until a new message arrives. 

Valid time period selections are: Disable, 2 minutes, 10 minutes and 60 minutes. 

  Duplicate Msg. 

If it is selected, duplication detection is performed on all personal messages with 

the same message type as the new message, on a character by character basis. 

Error characters are ignored during the check. If all non-error characters in both 

messages match, the existing matching message is flagged as a duplicate. The 

message with the least number of errors is stored and the other messages are 

discarded. Duplication is not performed on mail-drop messages. 

4

  Battery Gauge Level-High 

This value represents the battery voltage level necessary for the battery gauge to 

display a full battery. If the battery voltage is higher or equal to this value, the full 

battery gauge icon is displayed. Valid selections are: 1.58V, 1.53V, 1.48V, 1.43V, 

1.39V, 1.35V, 1.29V, 1.23V, 1.19V, 1.14V, 1.09V, 1.05V, and 1.00V. The High 

level must be greater than the Med level, and the Med level Must be greater than 

the Low level. None of the levels can be equal to each other. 

4

  Battery Gauge Level-Med 

This value represents the battery voltage level necessary for the battery gauge to 

display a full battery. If the battery voltage is higher or equal to this value, the full 

battery gauge icon is displayed. Valid selections are: 1.58V, 1.53V, 1.48V, 1.43V, 

1.39V, 1.35V, 1.29V, 1.23V, 1.19V, 1.14V, 1.09V, 1.05V, and 1.00V. The High 

level must be greater than the Med level, and the Med level Must be greater than 

the Low level. None of the levels can be equal to each other. 

4

  Battery Gauge Level-Low 

This value represents the battery voltage level necessary for the battery gauge to 

display a full battery. If the battery voltage is higher or equal to this value, the full 

battery gauge icon is displayed. Valid selections are: 1.58V, 1.53V, 1.48V, 1.43V, 

1.39V, 1.35V, 1.29V, 1.23V, 1.19V, 1.14V, 1.09V, 1.05V, and 1.00V. The High 

level must be greater than the Med level, and the Med level Must be greater than 

the Low level. None of the levels can be equal to each other. 

  Push Key Lamp On Enable 

If it is selected, the back-light will turn on after any key be pressed. 

Содержание AL-A25

Страница 1: ...Alpha Numeric Display Pager MODEL AL A25 ...

Страница 2: ...OGRAMMER SOFTWARE 3 INSTALLATION 3 RUNNING 7 ALA25 PROGRAMMING 8 INTRODUCTION 8 STARTING THE PROGRAMMER 8 MAIN MENU 10 MENU BAR 10 FREQ CODES 12 Frequency 12 Capcode Decimal Address 13 Message Type Status 15 Auto Increase 1 after write 18 ALERTS AND STATUS 19 Alerts and Status 20 Manu Of Pager 22 Manual Write 23 Prompts 23 PROMPTS EDIT 24 ...

Страница 3: ...o install and operate the programmer you need a system that meets the following minimum requirements An personal computer PC with printer port or compatible Windows 98 SE or above operating system XP Recommended 256 MB of RAM ALA25 Programmer An USB cable ALA25 Pager Programming Software Equipment Setup Refer to Figure 1 while performing the follows 1 At the rear of the PC connect the USB cable to...

Страница 4: ...MMING SOFTWARE Getting Started May 16 2007 2 ALA25 Figure Figure Figure Figure 1 1 1 1 Programmer Hardware Connections Programmer Hardware Connections Programmer Hardware Connections Programmer Hardware Connections ...

Страница 5: ...2007 3 ALA25 Installing Programmer Software Installation Install the programmer software into a PC as follows 1 Uncompress the ALA25B USB V50 NR zip and save them in a temporary directory 2 Double click the setup exe file Click on Y 3 Click Next on the Welcome screen ...

Страница 6: ...Installing Programmer Software May 16 2007 4 ALA25 4 Enter your user information and click Next Note you must enter at least a single character into the company field 5 Choose where the program should be installed and click Next ...

Страница 7: ...AGER PROGRAMMING SOFTWARE Installing Programmer Software May 16 2007 5 ALA25 6 On the Select Program Folder screen choose where you would like the program to show up in your start menu and click Install ...

Страница 8: ...ARE Installing Programmer Software May 16 2007 6 ALA25 7 If you had installed USB driver then select reboot now and click Finish on the setup complete screen 8 If you did not install USB driver click OK to install USB driver ...

Страница 9: ... Programmer Software May 16 2007 7 ALA25 9 Please reboot your computer after USB driver and programming software installed Running You now have the program installed To run it from the Start menu Programs Gold Apollo ALA25 Pager Programmer ...

Страница 10: ...on and restart the programming software of ALA25 4 Align the pager contact pin holes with the contact pins of the ALA25 Programmer 5 Press down on the pager until it is tight in the fixture 6 Turn the pager off or wait the pager until standby mode The pager is now ready to read or program Starting the Programmer 1 The application can be launched from Start Programs Gold Apollo ALA25 Pager Programm...

Страница 11: ...the system examines that the ALA25 programmer is well installed If any questions the following window appears 4 Please re check the ALA25 programmer and printer port are well installed or not If connection succeeds with the ALA25 programmer the system enters the Main Menu ...

Страница 12: ...ubmenus like those conventionally used in Windows applications G File Open Open the AL924 code plug file The file has the extension tbl G File Save Save the current code plug data to a file G File Save As Save the current code plug data to a file with different filename G Pager Write Write the current code plug data to the pager ...

Страница 13: ... PROGRAMMING SOFTWARE ALA25 Programming May 16 2007 11 ALA25 G Pager Read Read code plug data from the pager G Pager Verify Verify the pager data G Help Information about the ALA25 pager programming version ...

Страница 14: ...ALA25 Freq Codes Frequency 4 Range Of Frequency You can select the range of frequency and all setting will load default value 4 Frequency Of Pager The frequency is on which the pager operates 4 POCSAG Signal Baud Rate The baud rate is on which the pager operates ...

Страница 15: ...LA25 Programming May 16 2007 13 ALA25 Capcode Decimal Address 4 Cap 1 Please input 1st Capcode 7 Dec digits between 8 and 2097151 ON Enable or disable 2nd Capcode address 4 Fun Bit Click to set function bit A B C D message control ...

Страница 16: ...ble is disable ִ Priority Function Bit A B C D Priority Alert V is Enable is disable ִ Disp Function Bit A B C D Message Display N Standard Number P PRC Number A Alpha number I Ideographic ִ Type Function Bit A B C D Message Type P Personal 1 to 9 Mail Drop 1 to Mail Drop 9 A to E Mail Drop A to Mail Drop E G Group ...

Страница 17: ...PAGER PROGRAMMING SOFTWARE ALA25 Programming May 16 2007 15 ALA25 Message Type Status 4 Msg Status Select Click to set personal and mail drop 1 9 A E messages status ...

Страница 18: ...PAGER PROGRAMMING SOFTWARE ALA25 Programming May 16 2007 16 ALA25 ...

Страница 19: ...lections for all personal and group call messages alerts are 02 2 sec 08 8 sec 16 16 sec 32 32 sec CT continuous ִ Mail Drop Alert Length The available selections for mail drop messages alerts are Disable BP Short Beep 01 1 sec 16 16 sec ִ History The selections are only available on mail drop addresses The pager can ...

Страница 20: ...e available selections for mail drop memory size are 0 5 KB 1 0 KB 1 5KB 2 0 KB 2 5 KB and 3 0 KB The available selections for personal memory size are 3 KB 15KB Auto Increase 1 after write 1st Capcode Auto Increase 1st capcode always increment by one after write 2nd Capcode Auto Increase 2nd capcode always increment by one after write ...

Страница 21: ...PAGER PROGRAMMING SOFTWARE ALA25 Programming May 16 2007 19 ALA25 Alerts and Status ...

Страница 22: ...card Error Msg If it is selected error message will be discarded Disp Source Addr ON If it is selected the message will show the address source at last 4 Sequential Lockout The value is a sequential lockout timer begins when a message arrives and is flagged as being sequentially locked out If duplicate messages arrive one of the messages is disregarded and not flagged as a duplicate Valid selectio...

Страница 23: ...selections are 1 58V 1 53V 1 48V 1 43V 1 39V 1 35V 1 29V 1 23V 1 19V 1 14V 1 09V 1 05V and 1 00V The High level must be greater than the Med level and the Med level Must be greater than the Low level None of the levels can be equal to each other 4 Battery Gauge Level Med This value represents the battery voltage level necessary for the battery gauge to display a full battery If the battery voltage...

Страница 24: ...not detect a POCSAG synchronization word for that time period The out of service icon displays at this time Valid selections are disabled 1 min 2 min 5 min and 10 min 4 Read Time Out The current pager display changes after the selected time frame has expired Valid selections are 8 sec 12 sec 20 sec 30 sec 4 Password 4 Dec It is used for the user s manual programming 4 Screen Contrast It selects th...

Страница 25: ...one of 5 type alerts as your default Zoom In Disable If it is selected menu of zoom function will be disabled Manual Write Manual Write Enable If it is selected manual write enable Frequency Modification Enable If it is selected frequency modification is enabled at manual programming Password Required Enable If it is selected enters manual programming password is required Password Modification Ena...

Страница 26: ...PAGER PROGRAMMING SOFTWARE ALA25 Programming May 16 2007 24 ALA25 Prompts Edit Each prompt can be customized in the code lug if desired or the defaults can be used ...

Отзывы: