ADVANTAGES AND EQUIPMENT
Inlet connector on the gas cylinder
Outlet connection
Safety valve with
red
plastic cap
Handwheel
Label gas type PROPAN
Arrow direction OPEN „
+
“ or CLOSED „
-
“
Safety valve:
•
self-closing pressure relief valve; when the set pressure is exceeded, the valve opens
automatically to relieve the pressure
•
closes automatically when the pressure is below the set limit again
•
the settings on the safety valve must not be changed
•
there is a
red
plastic cap at the outlet of the safety valve
The
red
plastic cap must sit tightly on the outlet of the safety valve to prevent dirt
and water entering.
If the
red
plastic cap is missing, it is possible that the safety valve has been triggered.
CONNECTIONS
Inlet, optional
Trading name and dimensions
acc. to standard
Installation
instructions
GAZ thread connector
•
with gasket NBR
•
G.3
= Gewinde M 16 x 1.5-rh
Tighten hand-tight.
Primus thread connector
•
G.32
= M14 x 1.5-rh
•
with gasket NBR
Tighten hand-tight.
Outlet
Trading name and dimensions
acc. to standard
Installation
instructions
Male thread connector small cylinder KLF
•
gasket in the connector
•
G.12
= W 21.8 x 1/14-lh
Tighten hand-tight.