Goiot SLIM 6 Скачать руководство пользователя страница 4

 

 
 
 

SEAL REPLACEMENT PROCEDURE                              

 

 

 

1)  Carefully remove the faulty seal, for removing a maximum of pollution and glue 

residue in the groove. The groove must be free of any pollution. If it is not the 
case, clean it with a cleanser type ISOPROPYL ALCOHOL. 

 

 

2)  Once the seal is completely removed and the groove is clean, the frame is ready to receive the new 

seal 
 

 

3)  Place a continuous bead of Sika silicone (ref GOIOT: 121056) in the entire groove, except for the 

back of the hinges 
 

 

4)  Place the seal around the frame, sliding it under the lid of the hatch. To facilitate 

this operation, close the opening at 45 ° to pass the seal underneath and place 
it above the groove. 

 

5)  Press on the seal base (see yellow arrow on diagram) with the fingers to 

engage the foot in the groove, insist on the hatch corners. 

 

 
 
 
 
 
 

 

6)  Finish by snapping the seal behind the hinges with a Ø6 rod or equivalent without pointed end or sharp  

Edges (for example with an Allen key). 
 
 
 
 
 
 

7)  Check that the top of the seal lip is perfectly continuous. A "wave" means that the foot of the seal is not 

 correctly inserted. See below : 
 

Green frame: the top of the lip of the joint is rectilinear. 

Red Frame: we observe a "wave". the seal is improperly inserted here 

 

 

 

 

Отзывы: