1. Over-Temperature Protection
● To avoid overheating and deteriorating the lash head, do not ire
more than 30 continuous lashes in fast succession at 1/1 full
power. After 30 continuous lashes, allow a rest time of at least 10
minutes.
● If you ire more than 30 continuous lashes and then ire more
lashes in short intervals, the inner over-temperature protection
function may be activated and make the recycling time about 10
to 15 seconds. If this occurs, allow a rest time of about 10
minutes, and the lash unit will then return to normal.
● When the over-temperature protection is started,
is shown on
the LCD display.
Number of lashes that will activate over-temperature
protection:
Power Output Level
Number of Flashes
1/1
30
1/2 +0.7
40
1/2 +0.3
50
1/2
60
1/4
(
+0.3,+0.7
)
100
1/8
(
+0.3,+0.7
)
200
1/16
(
+0.3,+0.7
)
300
1/32
(
+0.3,+0.7
)
500
1/64
(
+0.3,+0.7
)
1000
1/128
(
+0.3,+0.7
)
Number of lashes that will activate over-temperature
protection in high-speed sync mode:
Power Output Level
Number of Flashes
1/1
15
1/2
(
+0.3,+0.7
)
20
1/4
(
+0.3,+0.7
)
30
1/8
(
+0.3,+0.7
)
1/16
(
+0.3,+0.7
)
40
1/32
(
+0.3,+0.7
)
1/64
(
+0.3,+0.7
)
50
1/128
(
+0.3,+0.7
)
Protection Function