Copyright © 2018 Graphics One
Chapter 4 Operation and control
4.1 Normal operation of mechanical part
Check if mechanical drive part is normal or not before working and then lift feeding
pressure beam to adjust the tension force of blanket. Start to work till qualified
temperature.
a. After confirming the good earthing and correct power wiring of the system, set the
breaker inside the case at on position, then press the button for
“general power”,
then press the
“VFC (Variable Frequency Control )Run” key on the VFC (Variable
Frequency Control )panel and adjust the frequency to the suitable position;
b. Press
“heating” key to set the required temperature; which shall be decided
according to different fabrics of the customer. We propose that the user shall make
trial use by small size fabric and transfer paper when reaching the specified
temperature and make corresponding adjustment in case of over high or over low
temperature to ensure the quality of final product;
c. Put the fabrics and transfer paper on the fabric holder and paper holder on the
working table; when the temperature reaches the level for transfer printing, put the
fabrics on the table and lower down the press roller and let the fabrics enter the roller.
Note: the side of the transfer paper with ink shall face the fabrics and shall be placed
over the fabrics;
d. During the transfer printing process, the user may adjust the temperature in
accordance with the color of the printed pattern, or adjust the temperature by
controlling the speed of the tube.
e. Upon completion of the printing work, press
“cooling down” key and turn the hand
wheel to remove the belt from roller; and the heating is stopped, when the
temperature decreases to 80
℃
, the equipment will be automatically stopped.
f.
On special occasions
,
Can turn off the "total power" and the " heating" button
,
When host run after a given period to automatically shutdown, on normal occasions,
don’t recommend the use of this feature