Go Power GPSW-150 Скачать руководство пользователя страница 7

 

Go Power! SW150, SW300 Inverter 

Owner’s Manual

 

 

7

 

3.4  Rear view GP-SW300: 

 

 

 

 

 

 

 
 
 
 
 
 

a)  Chassis ground or to vehicle chassis using # 8 AWG wire.   

 

b) Ventilation 

ports: 

Do not obstruct, allow at least 1 inch for air flow. 

 

c) Battery 

terminals: 

Connect to 12 V battery or other 12 V power source:  [+] is positive and [-] is 
negative.  A reverse polarity connection will blow the internal fuse and may 
damage inverter permanently. 

 

4. Installation 

4.1 Where to install 

The power inverter should be installed in a location that meets the following 
requirements: 
 

Caution 

Do not connect this inverter and another AC source (generator or utility power) to the AC 
wiring or AC loads at the 

same

 time. Doing so will destroy the inverter and void the 

warranty, regardless whether the inverter is switched on or off. If you are using more than 
one AC source for the AC wiring or AC loads, it is highly recommended that you install an 
automatic transfer switch (GP-TS), available from Go-Power Electric Inc.

 

 

 

a)  Dry - Do not allow water to drip or splash on the inverter. 
 
b)  Cool - Ambient air temperature should be between 0°C and 40°C (the cooler the 

better). 

 
c)  Ventilated - Allow at least two inches of clearance around the inverter for air flow. 

Ensure the ventilation openings on the rear and bottom of the unit are not 
obstructed. 

 
d)  Safe - Do not install the inverter in the same compartment as batteries or in any 

compartment capable of igniting flammable liquids such as gasoline. 

 
e)  Inverter should be located within 10 feet of the batteries. 

 

b. Ventilation ports

Warning!  

Operation of the 
inverter without a 
proper ground 
connection may 
result in an 
electrical safety 
hazard. 

c.  Battery terminal

a.  Chassis ground 

Содержание GPSW-150

Страница 1: ...Go Power Manual GP SW150 Inverter GP SW300 Inverter Go Power Electric Inc PO Box 6033 Victoria BC V8P 5L4 Tel 866 247 6527 Fax 866 607 6527 Email info gpelectric com...

Страница 2: ...MAIN FUNCTION 4 4 INSTALLATION 7 5 OPERATION 9 6 OPERATING LIMITS 10 7 TROUBLESHOOTING 10 8 MAINTENANCE 11 9 WARRANTY 11 Go Power Electric Inc PO Box 6033 Victoria BC V8P 5L4 Toll Free Tel 866 247 65...

Страница 3: ...arity Fuse Over Under Voltage Over Temperature Low Battery Alarm 2 10 5 V 21 0 V Low Battery Shut Down 2 10 0 V 20 0 V Operating Temperature Range 0 40 C 32 F 104 F Storage Temperature Range 30 C 70 C...

Страница 4: ...ain function 3 1 Front view GP SW150 a AC outlet Outlet sockets available North America b ON OFF switch Power ON OFF switch leave in the OFF position during installation c Remote port d Power status b...

Страница 5: ...2 Front view GP SW300 a ON OFF switch Power ON OFF switch leave in the OFF position during installation b AC outlet Outlet sockets available North America c Remote port d Power status LED a ON OFF swi...

Страница 6: ...y or other power source black is negative red is positive A reverse polarity connection will blow the internal fuse and may damage inverter permanently c Chassis ground or to vehicle chassis using 8 A...

Страница 7: ...hether the inverter is switched on or off If you are using more than one AC source for the AC wiring or AC loads it is highly recommended that you install an automatic transfer switch GP TS available...

Страница 8: ...se into the positive lead Fuse should be located within 12 of battery Ensure all connections are tight and secure 4 4 Grounding The power inverter has a lug on the rear panel Chassis Ground This is to...

Страница 9: ...ode and there is no AC output Some common faults include 5 2 1 Over voltage indicator Red LED Blinking Fast The over voltage indicator indicates that the power inverter has shut itself down because it...

Страница 10: ...4 V The power inverter will shut down if the input voltage drops below 10 20 V This protects your battery from being over discharged The power inverter will also shut down if the input voltage exceeds...

Страница 11: ...k and replace fuse OBSERVE CORRECT POLARITY No output voltage Over Load indicator ON Short circuit or wiring error Check AC wiring for short circuit or improper polarity hot and neutral reversed 8 Mai...

Отзывы: