Go Power GPSW-1000 Скачать руководство пользователя страница 1

 

 
 
 
 
 
 
 
 
 

 

Go Power! Manual 

GP-SW3000 Inverter 
GP-SW2000 Inverter 
GP-SW1000 Inverter 
GP-SW600 Inverter 

Go Power! Electric Inc. 
PO Box 6033 
Victoria, BC  V8P 5L4 
Tel:  866-247-6527 
Fax: 866-607-6527 
Email: [email protected] 

 

 

Содержание GPSW-1000

Страница 1: ...Power Manual GP SW3000 Inverter GP SW2000 Inverter GP SW1000 Inverter GP SW600 Inverter Go Power Electric Inc PO Box 6033 Victoria BC V8P 5L4 Tel 866 247 6527 Fax 866 607 6527 Email info gpelectric c...

Страница 2: ...NSTALLATION 11 5 OPERATION 13 6 OPERATING LIMITS 15 7 TROUBLESHOOTING 15 8 MAINTENANCE 16 9 WARRANTY 16 10 CONFIGURING YOUR GP SW3000 GP SW2000 GP SW1000 AND GP SW600 17 Go Power Electric Inc PO Box 6...

Страница 3: ...this manual before installing and using this model 2 Specifications 2 1 GP SW3000 W Inverter Model GP SW3000 12 V GP SW3000 24 V Continuous output power 3000 W Surge rating 6000 W Output waveform Sine...

Страница 4: ...8 x 8 2 x 6 5 Weight 9 5 21 Warranty 2 years Inverter Install Kit GP DC Kit 4 GP DC Kit 3 2 3 GP SW1000 W Inverter Model No GP SW1000 12 V GP SW1000 24 V Continuous Output Power 1000 W Surge Rating 2...

Страница 5: ...0 30 0 VDC Efficiency 85 92 No Load Current Draw Powersave n a n a Protection Overload Short Circuit Reverse Polarity Fuse Over Under Voltage Over Temperature Low Battery Alarm 2 10 5 V 21 0 V Low Ba...

Страница 6: ...normal operation yellow indicates mid to high operation and red indicates overload levels e Status Level Displays operating condition Green indicates normal flashing green every second indicates Powe...

Страница 7: ...Status Level Displays operating condition Green indicates normal flashing green indicates Power Saving mode and red indicates a Fault See Section 5 for Power Saving and LED variations in Fault mode f...

Страница 8: ...operation yellow indicates mid or high operation and red indicates overload levels d Fault See Section 5 for LED variations in Fault mode e Frequency Typical North American setting is 60 Hz f Input L...

Страница 9: ...ound Ground to vehicle chassis using 8 AWG wire d Battery terminals Connect to 12 V battery or other 12 V power source is positive and is negative Reverse polarity connection will blow the internal fu...

Страница 10: ...ound to vehicle chassis using 8 AWG wire d Battery terminals Connect to 12 V battery or other 12 V power source is positive is negative Reverse polarity connection will blow the internal fuse and may...

Страница 11: ...ranty regardless of the inverter s on or off status If you are using more than one AC source for the AC wiring or AC loads it is highly recommended that you install an automatic transfer switch GP TS...

Страница 12: ...This is normal Plug the test load into the AC receptacle on the front panel of the inverter Leave the test load switch OFF For the Hard Wire option please see Section 4 3 9 Set the power inverter swit...

Страница 13: ...electrical code requirements that states that separately derived AC sources such as inverters and generators have their neutral tied to ground in the same way that the neutral conductor from the utili...

Страница 14: ...ut will disconnect 5 7 Low Under Voltage Indicator UVP During low voltage the Input Level LED will continually flash red twice per second and five single beeps will sound every eight seconds During un...

Страница 15: ...battery voltage and power consumption The remote will show if the battery voltage is too high and will sound an alarm if the battery voltage falls too low Under Voltage The remote will also sound an...

Страница 16: ...Under Voltage indicator on Low input voltage Recharge battery check connections and cable No output voltage Over Temp indicator on load in excess of 3000 W 250 A 12V or 125 A 24 V 2000 W 170A 12V or...

Страница 17: ...dip switches S1 S2 and S3 on the front of the inverter To disable power saving leave dip switches S1 S2 and S3 in the OFF or 0 position See Section 5 10 for additional information Power Saving S1 S2 S...

Отзывы: