![Go Power GP-PWM-30-SB Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/go-power/gp-pwm-30-sb/gp-pwm-30-sb_user-manual_2236830005.webp)
GP-PWM-30-SB
5
© 2019 Go Power!
Bulk/Absorption Voltage
(Sealed/GEL, AGM, Flooded)
14.1/14.4/14.4 VDC
(25°C / 77°F), 30min / Day
or 2hr if battery voltage < 12.3
VDC
•
Temperature
Compensated
•
RoHS Compliant,
Environmentally Safe
•
Accepts up to 510 or
540 Watts (for the
190watt Extreme) of
Solar at 12 Volts
Absorption Voltage (LiFePO
4
)
14.4V
30min / Day
Float Voltage (Sealed/Gel,
AGM, Flooded)
13.7V (25°C / 77°F)
Float Voltage (LiFePO
4
)
14.0V
Equalization Voltage
(Sealed only)
14.9V (25°C / 77°F),
2h / 28 Days
or if battery voltage < 12.1 VDC
Temperature Compensation
(Sealed/Gel, AGM, Flooded)
- 24mV/ºC / -13mV/ºF
USB charger
5V, 1500mA
Low Voltage Disconnect
(USB)
11.0 VDC
Reconnects once battery reaches:
12.8V for Sealed/Gel, AGM,
Flooded
12.2V for LiFePO
4
Operating Temperature
- 40 to 85°C / - 40 to 185°F
Display Operating
Temperature
- 10 to 55°C / 14 to 131°F
Humidity
99% N.C.
Protection
Battery Reverse Polarity, Solar
Array Reverse Polarity, Over
Temperature, PV Short Circuit,
Over Current