background image

 

 

 

 
 

 
 

Go Power! Manual 

 

GP-1750 Inverter 

 

GP-3000 Inverter 

 

 

 

Содержание GP-1750

Страница 1: ...Go Power Manual GP 1750 Inverter GP 3000 Inverter ...

Страница 2: ...ower Inverters can be used in a wide range of applications including RVs boats and light and heavy duty truck applications It will operate most televisions DVD players computers and small appliances including drills sanders grinders mixers blenders and microwaves To get the most out of your power inverter it must be installed and used properly Please read the instructions in this manual before ins...

Страница 3: ...erload over temperature over voltage low voltage Low Battery Alarm 10 5 0 5 V DC Low Battery Shut Down 10 0 5 V DC Overvoltage Shut Down 16 5 1 V DC Thermal Shut Down 150 F 66 C Operating Temperature Range 32 104 F 0 40 C Storage Temperature Range 22 158 F 30 70 C Cooling Thermostatically controlled fan AC Receptical North American standard x4 Dimensions L x W x H 19 x 9 4 x 3 3 482 x 240 x 83 mm ...

Страница 4: ... temperature over voltage low voltage Low Battery Alarm 10 5 0 5 V DC Low Battery Shut Down 10 0 5 V DC Overvoltage Shut Down 16 5 1 V DC Thermal Shut Down 150 F 66 C Operating Temperature Range 32 104 F 0 40 C Storage Temperature Range 22 158 F 30 70 C Cooling Thermostatically controlled fan AC Receptical North American standard x4 Dimensions L x W x H 14 4 x 9 1 x 6 2 365 x 230 x 158 mm Weight 1...

Страница 5: ...tage or current in the red zone will result in protective shutdown of the inverter c Overload indicator Lights up when inverter shuts down due to overloading Turn inverter OFF remove cause of overload and turn inverter ON to reset d Over temp indicator Lights up when inverter protects itself against overheating Inverter shuts down while indicator is on Inverter will restart automatically and indic...

Страница 6: ...t least 1 inch 2 54 cm for air flow b DC Power input terminal Black Negative c DC Power input terminal Red Positive d Chassis ground lug Connect the chassis ground to an earth ground or to vehicle chassis using 8 AWG wire The minimum inverter DC cable and DC inverter fuse sizes are listed in sections 4 3 and 4 4 ...

Страница 7: ...eration The inverter will operate for several minutes when the current is in the yellow zone Operation with battery voltage or current in the red zone will result in protective shutdown of the inverter c AC outlet Outlet sockets available North America d ON OFF switch Power ON OFF switch leave in the OFF position during installation e Power LED The LED display indicates the power status of the inv...

Страница 8: ...0 a DC Power input terminal Red Positive Suggested Hardware 5 16 b DC Power input terminal Black Negative Suggested Hardware 5 16 c Cooling fan Do not obstruct allow at least 1 inch 2 54 cm for air flow d Chassis ground lug Connect the chassis ground to an earth ground or to vehicle chassis using 8 AWG wire ...

Страница 9: ...verse polarity connection will permanently damage the inverter Damage caused by reverse polarity connection is not covered by the warranty This inverter must only be connected to batteries with a nominal output voltage of 12 V Lower voltages will not operate the inverter properly and higher voltages could damage the inverter or the device being powered If more than one 12 V battery is used the bat...

Страница 10: ...oy the unit and void the warranty If you do not understand neutral to ground bonding then please have a professional install your system for you See Grounding for more information 9 Set the power switch to the ON position Check the meters and indicators on the front panel of the inverter The voltage bar graph should indicate 11 to 14 V depending on the voltage of the power source If it is does not...

Страница 11: ...power inverter has a lug on the rear panel Chassis Ground This is to connect the chassis of the power inverter to a grounding point The power inverter grounding point will vary depending on where the power inverter is installed In a vehicle connect the chassis ground to the chassis of the vehicle In a boat connect to the boat s grounding systems In a fixed location connect the chassis ground lug t...

Страница 12: ...e Wave Inverter Owner s Manual Installation using two 12 V batteries in parallel Installation using two 6 V batteries in series Installation using two 6 V batteries Fuse GP Inverter _ GP Inverter Fuse _ 12 V 6 V 12 V 6 V _ ...

Страница 13: ...r bottom of the graph the inverter may shut down 5 4 Battery current indicator The battery current bar graph indicates the current drawn from the battery by the power inverter It will not indicate current by other loads also connected to the battery For long term operation the current should be in the green area of the bar graph Short term operation is possible with current in the yellow area If t...

Страница 14: ...e inverter Remove the hard wire cover and carefully pull out the three wires Do Not remove the hardwiring from the inverter while battery power is supplied to the inverter Remove the knockout on the hard wire cover Pull the three wires through the knockout opening and reattach the hard wire cover Install a cord grip or strain relief to protect the wires The ground wire output is yellow and green c...

Страница 15: ... antenna and the television Move the television as far away from the power inverter as possible Keep the cables between the battery and the power inverter as short as possible and twist them together with about 2 to 3 twists per foot This minimizes radiated interference from the cables 6 2 Troubleshooting guide Problem and Symptoms Possible Cause Solution Low AC output voltage 95 105 VAC Using sta...

Страница 16: ...on make sure ventilation openings in inverter are not obstructed Reduce ambient temperature No output voltage Error indicator on Short circuit or wiring error Check AC wiring for short circuit to ground or improper wiring 7 0 Maintenance Very little maintenance is required to keep your inverter operating properly Keep the exterior of the inverter clean and dry Unplug the inverter before cleaning P...

Страница 17: ... when power is not required Installing the GP 1750 GP 3000 with an automatic transfer switch Battery inter connects should be a minimum of 4 gauge Ensure converter is turned Off when inverter is operating To avoid hidden loads turn inverter off when power is not required DC connections use appropriate GP DC Install Kit 12 V Batteries On Off Remote Optional Shore Power Cord Go Power Transfer Switch...

Отзывы: