Instr. 4770-65-95005-00 Page 15
9.1 SCR100 CHARGER FUNCTIONAL
DESCRIPTION
This section gives a brief description of each LED,
pushbutton, and the delay function on the SCR100 type
charger front control panel.
9.1.1 DELAY STAGE
9.1.1.1
DELAY CIRCUIT
CAUTION: HAZARDOUS VOLTAGES INSIDE. DO NOT
ATTEMPT TO CHANGE THE SLIDE SWITCHES ON
THE CONTROL CARD UNTIL ALL AC POWER IS
DISCONNECTED FROM THE UNIT AS WELL AS THE
BATTERY IS UNPLUGGED FROM THE CHARGER.
USE PROPER TOOL TO OPEN THE CABINET DOOR.
1. The delay circuit enables the user to set a delay of up
to eight hours between battery plug in and the start of
charge.
2. The delay time must be set prior to charging. This can
be done via the slide switches located on the back of
the charger control card. Refer to Table 5 below for
details.
CAUTION: DO NOT TOUCH THE OTHER SLIDE
SWITCHES ON THE BACK OF THE CONTROL
BOARD. THESE ARE FACTORY SET AND CAN ONLY
BE CHANGED BY A QUALIFIED GNB SERVICE
REPRESENTATIVE.
TABLE 5
SW5
1
2
3
START DELAY
(HOURS)
ON
ON
ON
0 (DEFAULT)
OFF
ON
ON
1
ON
OFF
ON
2
OFF
OFF
ON
3
ON
ON
OFF
4
OFF
ON
OFF
5
ON
OFF
OFF
6
OFF
OFF
OFF
8
9.1.1.2
DELAY LED
This LED indicates that the charger is in the delay mode
and charging will not start until the delay time has
elapsed. A flashing Delay LED indicates that the delay is
in progress.
9.1.1.3
START DELAY OVERRIDE
This pushbutton will override the charger delay mode and
charging will start immediately.
9.1.2 CHARGING
9.1.2.1 SMART START STAGE
Smart Start is only available on Z model chargers and
replacement boards.
The charge cycle starts with Finish Rate current. If the
voltage reaches 2.18VPC + 1% (Sealed /Flooded) within
5 minutes, the charger goes to the Refresh Charge
Stage. If it does not reach the above voltage in 5 minutes
the charger will go to the High Rate charging stage.
9.1.2.2 CHARGING LED
This LED indicates that the charger is ON.
9.1.2.3 80 % CHARGED LED
This LED indicates that the battery has reached 80%
charge.
9.1.2.4 CHARGE COMPLETE LED
When this LED is continuously lit it indicates that the
charging cycle is complete. The battery may now be
safely disconnected. In the event this LED is flashing, it
indicates that cooldown is in progress.
9.1.2.5 FAULT LED
This LED is associated with any fault that is described in
Appendix A
SCR100 BATTERY CHARGERS. LIST
OF DISPLAY CODES
(page 20)
.
It
indicates that there
is a problem prior to or during the battery charging
operation.
9.1.3 DISPLAY
The display shows the charging current to the battery
during the charging process. The display will show
additional messages as the charging is progressing or a
fault occurs.
9.1.4 STOP PUSHBUTTON
This pushbutton will STOP the charge cycle. The battery
can then be safely unplugged. The red fault LED will light
to indicate that the charge cycle was interrupted.
9.1.5 BATTERY COOLDOWN OPERATION
STAGE
Cool Down step is only available on Z model chargers
and replacement boards.
A cooldown period is incorporated in the charge cycle.
This stage serves to cool down the battery before being
placed back in service. During this time the display will
alternate between “COL” and time remaining in this stage.
If the battery is unplugged during cooldown the display will
show “FCD”. During the cooldown period, Equalize can
be activated by pressing the Equalize button. If this
Содержание SCR100-06-260S1Z
Страница 1: ...INSTALLATION OPERATING INSTRUCTIONS SCR 100 SERIES INDUSTRIAL BATTERY CHARGERS ...
Страница 2: ......
Страница 4: ......
Страница 25: ...Instr 4770 65 95005 00 Page 21 APPENDIX B ELECTRICAL SCHEMATIC DRAWINGS Pages 21 31 ...
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......