GNB LiftForce Скачать руководство пользователя страница 7

LiFTFORCE Material Handling Battery Operating Instructions 08/01/18 

Page 

7

 of 

9

 

The system is designed to accept regular opportunity charging. Whenever the system is not in operation, it 
should ideally be placed on charge. 

LiFTFORCE batteries are fitted with Drive Away Protection and separate cables for charger and vehicle. 
Power to the vehicle is automatically disabled while the battery is charging and therefore does not require 
an ON/OFF switch.    

 5.1.2  Charging 

Only GNB HF Approved Lithium chargers are to be used with the system. Standard Lead Acid chargers are 
not compatible and may damage the Lithium system.  

For maximum charge voltage see battery label. 

If you attempt to charge the battery below 0°C then the battery system will disconnect. If the system is 
required to operate below 0°C then an additional low temperature kit should be supplied with the system. 

The system LED is illuminated when the battery is connected to the vehicle or charger. 

 5.1.2  Balancing charging 

When not in use the vehicle must be placed on charge.  It is strongly recommended that the vehicle is 
placed on charge for a period of at least 6 hours once every week. Without this “maintenance charge” the 
system performance will not be optimised. Balancing charge is completed if the charger shows “charge 
complete” (i.e. all LEDs are shown green) 

5.3  Over Discharge Protection 

 
IF THE BUZZER STARTS TO BEEP FOR LOW SOC WHILE THE VEHICLE IS BEING USED, IT SHOULD BE 
RETURNED TO THE CHARGER AS SOON AS POSSIBLE. IF THE BUZZER SOUNDS CONTINUOUSLY, THE 
VEHICLE SHOULD BE STOPPED IMMEDIATELY. 

 
When the SOC of the battery is low, one of the following will happen, depending on the operational mode:  
 

5.3.1  Discharge mode: 

 

 

A 5 minute timer is started; a buzzer beeps once every 8 seconds and the LED on the battery flashes 
quickly. This gives the operator sufficient time to take the vehicle to the charger.  When 1 minute 
remains, the buzzer beeps once every 4 seconds and then for the last 10 seconds the buzzer is 
continuous, indicating that the vehicle will STOP imminently. 

 

If the 5 minute timer has expired and the vehicle has not been placed on charge the battery will 
shut down and the LED will pulse slowly. 

 

The battery pack can be temporarily re-enabled by pressing the reset button on the battery; this 
allows the vehicle to drive short distances and return to the charger. The reset button will re-
enable the battery pack for a certain period of time, which reduces with each reset press.

 

5.3.2  Charge mode: 

 

 

If the battery is at a low SOC, a 30 minute timer is started to allow sufficient time for the charger to 
charge the battery above the threshold.  The LED will flash slowly and the buzzer will be off.  The 
operator should not notice any difference from normal charging. 

Содержание LiftForce

Страница 1: ...LiFTFORCE Material Handling Battery Operating Instructions 08 01 18 Page 1 of 9 GNB LiFTFORCE Material Handling Battery Operating Instructions ...

Страница 2: ...Sledge Contents 1 Revision Table 2 2 WARNINGS AND GENERAL INFORMATION 3 3 GENERAL DATA 4 4 SYSTEM OVERVIEW 4 5 OPERATING INSTRUCTIONS 6 5 1 Start Up and Normal Running 6 5 1 1 Discharging 6 5 1 2 Balancing charging 7 5 3 Over Discharge Protection 7 5 3 1 Discharge mode 7 5 3 2 Charge mode 7 6 MAINTENANCE 8 7 STORAGE 8 8 BUZZER SUMMARY 8 9 SYSTEM LED SUMMARY 8 ...

Страница 3: ...up on the poles or communication cables Explosion and fire hazard Avoid short circuits Avoid electrostatic charges and discharges sparks While working on batteries wear protective eye glasses and clothing Observe the accident prevention rules as well as EN 50272 2 and EN 50110 1 Observe these Instructions and keep them located near the battery for future reference Work on the battery should only b...

Страница 4: ...d with a Curtis Engage II gauge or Opus A3 display which shows battery parameters during charge and discharge The battery is fitted with an over discharge protection device which will prevent the battery entering a critical level of discharge A buzzer is fitted to the vehicle to alert the operator of this situation Both the display and the buzzer need to be mounted in a convenient place on the veh...

Страница 5: ...seen in Figure 2 below Fig 2 The Curtis display can be seen in Figure 3 below Fig 3 Curtis Display The Curtis display will show both a bar and text value of the State of Charge SOC of the battery from 100 to 0 The LED on the right of the gauge will flash from 20 to 15 SOC and will be permanently on below ...

Страница 6: ...fective solution Fig 4 Fig 5 Fig 6 Fig 7 In addition to low SOC warnings the buzzer will sound on warnings for Under Over Voltage Under Over Temperature and LMU internal electronics Over Temperature The system will only shut down for low SOC However if the warnings indicated escalate further the Battery Management System may take action by shutting down the battery If this occurs please contact Ex...

Страница 7: ...rger shows charge complete i e all LEDs are shown green 5 3 Over Discharge Protection IF THE BUZZER STARTS TO BEEP FOR LOW SOC WHILE THE VEHICLE IS BEING USED IT SHOULD BE RETURNED TO THE CHARGER AS SOON AS POSSIBLE IF THE BUZZER SOUNDS CONTINUOUSLY THE VEHICLE SHOULD BE STOPPED IMMEDIATELY When the SOC of the battery is low one of the following will happen depending on the operational mode 5 3 1 ...

Страница 8: ...e fully charged and disconnected from both the vehicle and the charger 8 BUZZER SUMMARY One beep This indicates that the battery pack has been powered up by being connected to either the charger or the vehicle ACTION No action required this is normal operation Slow beep Once every 8 seconds The battery is at a low SOC and will switch off after 5 minutes Or one or more of the warnings described in ...

Страница 9: ...h Once every 3 seconds The battery is at a low SOC but has been connected to the charger ACTION Normal operation Note If the battery has not cleared the low SOC warning within 30 minutes the battery pack will shut down as a safety precaution Very Slow Flash Once per 5 seconds The battery has shut down as it is at a very low SOC ACTION Charge the battery as soon as possible gnb com 888 563 6300 Mil...