LiFTFORCE LPX 2.0 Operating Instructions
4
TECHNICAL SPECIFICATIONS
Voltage
See battery label
Capacity
See battery label
Charger
GNB recommends Fury series for best performance,
but ELI series also approved
For max charge voltage, see battery label
Maximum Charge Rate
Not to exceed 0.7 C ( 70 Amps per 100Ah capacity)
Operating Conditions*
Storage Temperature
-4ºF to 140ºF (-20ºC — 60ºC)
Communication
CAN Open Communication(optional customized Communication
available)
Display
Curtis Engage II (Figure 2) or Opus A3 (Figure 3)
Weight
See battery label
*Notes:
Discharge:
If the internal battery temperature falls below -4ºF (-20ºC) the battery will disconnect
If the battery internal temperature reaches 140ºF (60ºC) the battery will disconnect.
Derating message is transmitted at 131ºF (55ºC.)
Charge:
Charging is forbidden below an internal battery temperature of 32ºF (0ºC.)
If the battery internal temperature reaches 122ºF (50ºC) the battery will disconnect.
Charge current derating occurs at 113ºF (45ºC.)
For cold store operations or operations in a cold environment, please contact GNB.
©2020 Stryten Manufacturing Alpharetta, GA 30022. GB5130 11/20
GNB INDUSTRIAL POWER
USA/PR
877.462.4636
CAN
800.268.2698
MEX
+52 5543527927