![GMS GDS-27 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/gms/gds-27/gds-27_instruction-manual_2236420015.webp)
15
GMS GDS–27
GDS – 27
Type and electrode performance:
10
– Bar, uncoated, lengths 50 or 100 mm
11
– Bar, short, fully insulated 30 mm
20
– Rod, partly coated, lengths 0.1 ... 1 m
21
– Rod, fully coated (FEP), lengths 0.1 ... 1 m
22
– Rod, fully coated (PFA), lengths 0.1 ... 1 m
30
– Rod, uncoated (dismountable), lengths 0.1 ... 3 m
31
– Rod, fully coated, lengths 0.1 ... 3 m
40
– Rope, uncoated rope and weight, lengths 1 ... 6 m
Length of electrode in mm
–
–
–
–
E
Output state at non activated electrode:
O
– Open
C
– Closed
Type of output:
N
– NPN (open collector)
P
– PNP (open collector)
Electric connection:
B
– Cable outlet (+ Spec. the length of the cable)
C
– Connector (+ Spec. type of the socket)
Performance:
N
– Normal (for non-explosive areas)
NT
– High temperature performance
Process connection:
G
– Pipe thread G3/4"
M27
– Metric thread M27x2
M30
– Metric thread M30x1,5
Cl
– Tri-clamp coupling
10. o
rder
code
11. c
orrect
SPecification
examPleS
GDS–27N–10–B–NO–M27 E100 cable 5 m
(N)
Normal performance;
(10)
Uncoated bar electrode,
(B)
Cable outlet with 5 m length cable;
(NO)
Output type NPN with open state at
non-activated electrode;
(M27)
Metric thread M27x2 process connection;
(E100)
Electrode length 100 mm
GDS–27NT–21–C–PC–G E580
(NT)
High temperature performance;
(21)
Fully coated rod electrode (FEP);
(C)
Connector;
(PC)
Output type NPN with closed state at
non-activated electrode;
(G)
Pipe thread G3/4" process connection;
(E580)
Electrode length 580 mm.
Cable
– Length of cable in m