![GMP Breeze 89010 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/gmp/breeze-89010/breeze-89010_operation-and-maintenance-manual_2236405021.webp)
Page 21 of 42
General Machine Products (KT), LLC
7. Procedure for changing inserts in the tube clamp
Loosen the thumb nut,
rotate the swing bolt to
open the tube clamp
Remove the insert
Repeat the process for
the insert in the other
housing half
Loosen and remove the
two mounting screws. (Do
not lose these screws,
they will be needed for the
replacement insert).
8. Procedure for changing inserts in air box
Loosen the thumb nut, rotate the
swing bolt to open the air box
Loosen and remove the mounting
screw. (Do not lose this screw, it
will be needed for the replacement
insert)
Remove the insert
Repeat the process for the insert
in the other box half
To fit the new inserts, reverse
the disassembly procedure.
To fit the new inserts, reverse
the disassembly procedure.
Содержание Breeze 89010
Страница 31: ...Page 31 of 42 General Machine Products KT LLC Page intentionally left blank ...
Страница 39: ...Page 39 of 42 General Machine Products KT LLC ...
Страница 40: ...Page 40 of 42 General Machine Products KT LLC Page intentionally left blank ...
Страница 41: ...Page 41 of 42 General Machine Products KT LLC ...