background image

 

D6003 

- 3 A Relay Output Module for Termination Board 

G.M. International ISM0395-3 

 

 

 

Technical Data 

Characteristics 

Input: 

24 Vdc nom (21.6 to 27.6 Vdc). Relay coil are internally protected with suppressor diodes. 

Current consumption @ 24 V:

 10 mA typical. 

Power dissipation @ 24 V:

 0.24 W typical. 

Supply: 

24 Vdc nom (20 to 30 Vdc), from Termination Board. 

Output: 

1 voltage free SPDT relay contact identified with outputs: Out 1 (NO contact) terminals 7-8 and Out 2 (NC contact) terminals 9-10. 

Terminals 7-8 (Out 1) are open when relay is de-energized , closed in energized relay condition. 
Terminals 9-10 are closed when relay is de-energized, open in energized relay condition.

 

Contact material: 

Ag Alloy (Cd free), gold plated. 

Contact rating: 

3 A 30 Vdc 90 W (resistive load). 

Min.switching current 1 mA. 

Contact inrush current: 

6 A at 24 Vdc. 

Mechanical / Electrical life: 

5 * 10

6

 / 3 * 10

4

 operation, typical. 

Operate / Release time: 

6 ms / 12 ms typical, including contact bounce time. 

Frequency response: 

10 Hz maximum.

 

Compatibility: 

CE mark compliant, conforms to Directives:  
2014/34/EU ATEX, 2014/30/EU EMC, 2014/35/EU LVD, 2011/65/EU RoHS. 

Environmental conditions: 

Operating:

 temperature limits – 40 to + 70 °C, relative humidity 95 %, up to 55 °C. 

Max altitude:

 2000 m a.s.l. 

Storage:

 temperature limits - 45 to + 80 °C. 

Safety Description: 

ATEX:

 II 3G Ex ec nC IIC T4 Gc 

IECEx:

 Ex ec nC IIC T4 Gc 

UL:

 NI / I / 2 / ABCD / T4 

C-UL:

 NI / I / 2 / ABCD / T4 

Approvals:  

BVS 18 ATEX E 079 X conforms to EN60079-0, EN60079-7, EN60079-15. 
IECEx BVS 18.0066X conforms to IEC60079-0, IEC60079-7, IEC60079-15. 
UL & C-UL E222308 conforms to UL 61010-1 and UL 121201 for UL and CAN/CSA C22.2 No.61010-1-12 and CSA C22.2 No. 213 for C-UL. 

Mounting: 

on customized Termination Board. 

Weight:

 about 110 g. 

Connection:

 by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm

2

Location:

 installation in Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4 or Class I, Division 2, Group A,B,C,D, T4. 

Protection class:

 IP 20. 

Dimensions: 

Width 12.5 mm, Depth 123 mm, Height 120 mm. 

General Description:

 

The single channel D6003S is a Relay Output module, which provides an SPDT (Single Pole Double Throw) contact. The load is energized by the power supply of the Termination 
Board. 

 

Mounting on customized Termination Boards, in Safe Area / Non Hazardous Location or in Zone 2 / Class I, Division 2. 

Отзывы: