background image

G X 8 0 0  

I N S T R U C T I O N   M A N UA L   

2 3

STANDARD COMMUNICATIONS CONTRACT WARRANTY AGAINST DEFECTS

This warranty against defects is given by Standard 
Communications Pty Ltd ACN 000 346 814 (We, us, our 
or GME). Our contact details are set out in clause 2.7. This 
warranty statement only applies to products purchased in 
Australia. Please contact your local GME distributor for 
products sold outside of Australia. Local distributor details at 
www.gme.net.au/export.

1.  Consumer guarantees

1.1  Our goods come with guarantees that cannot be 

excluded under the Australian Consumer Law. You 
are entitled to a replacement or refund for a major 
failure and for compensation for any other reasonably 
foreseeable loss or damage. You are also entitled to have 
the goods repaired or replaced if the goods fail to be of 
acceptable quality and the failure does not amount to a 
major failure.

1.2  To the extent we are able; we exclude all other conditions, 

warranties and obligations which would otherwise  
be implied.

2.   Warranty against defects

2. 1  This warranty is in addition to and does not limit, 

exclude or restrict your rights under the Competition and 
Consumer Act 2010 (Australia) or any other mandatory 
protection laws that may apply.

2.2  We warrant our goods to be free from defects in materials 

and workmanship for the warranty period (see warranty 
table) from the date of original sale (or another period 
we agree to in writing). Subject to our obligations under 
clause 1.2, we will at our option, either repair or replace 
goods which we are satisfied are defective. We warrant 
any replacement parts for the remainder of the period of 
warranty for the goods into which they are incorporated.

2.3  To the extent permitted by law, our sole liability for 

breach of a condition, warranty or other obligation 
implied by law is limited.

 

(a)  in the case of goods we supply, to any one of the 

following as we decide –

 

(i)  the replacement of the goods or the supply of 

equivalent goods;

 

(ii) the repair of the goods;

 

(iii)  the cost of repairing the goods or of acquiring 

equivalent goods;

 

(b)  in the case of services we supply, to any one of the 

following as we decide -

 

(i) the supplying of the services again;

 

(ii) the cost of having the services supplied again.

2.4  For repairs outside the warranty period, we warrant 

our repairs to be free from defects in materials and 
workmanship for three months from the date of the 
original repair. We agree to re-repair or replace (at our 
option) any materials or workmanship which we are 
satisfied are defective.

2.5  We warrant that we will perform services with reasonable 

care and skill and agree to investigate any complaint 
regarding our services made in good faith. If we are 
satisfied that the complaint is justified, and as our 
sole liability to you under this warranty (to the extent 
permitted at law), we agree to supply those services 
again at no extra charge to you.

2.6  To make a warranty claim you must before the end of 

the applicable warranty period (see warranty table), at 
your own cost, return the goods you allege are defective, 
provide written details of the defect, and give us an 
original or copy of the sales invoice or some other 
evidence showing details of the transaction.

2.7 Send your claim to:
 Standard Communications Pty Ltd. 
 PO Box 96, Winston Hills, NSW 2153, Australia. 
 Tel: 1300 463 463  
 

Email: [email protected]

Содержание G-COM GX800W

Страница 1: ...TRUCTION MANUAL 1 Print CMYK on 90 gsm gloss art both sides Flat Size 266 x 157 folded to 133 w x 157 h mm stitch with 2 wires 24 pages Part Number 310615 Drawing Number 47023 1 I N S T R U C T I O N M A N U A L ...

Страница 2: ...MARINE VHF CHANNELS AND FREQUENCIES 12 US MARINE VHF CHANNELS AND FREQUENCIES 14 CANADIAN MARINE VHF CHANNELS AND FREQUENCIES 17 SPECIFICATIONS 21 SC CONTRACT WARRANTY AGAINST DEFECTS 23 FEATURES Waterproof to IP67 5 1 watt Switchable Power Large LCD Private Channel Facility Programmable Scan Priority Scan Dual and Tri Watch All International US and Canadian Marine VHF Channels Weather channels on...

Страница 3: ...tions 47CFR part 2 sub part J American National Standards Institute ANSI Institute of Electrical and Electronic Engineers IEEE C95 1 1992 Institute of Electrical and Electronic Engineers IEEE C95 1 1999 International Commission on Non Ionizing Radiation Protection ICNIRP 1998 FCC Regulations Federal Communication Commission FCC requires that all radio communication products should meet the require...

Страница 4: ...en you are not operating on another channel False or fraudulent distress calls are prohibited under law Privacy Information overheard but not intended for you cannot lawfully be used in any way Indecent or profane language is prohibited RADIO LICENCES Ship Station License When your craft is equipped with a VHF FM radio you must have a current radio station licence before using the radio It is unla...

Страница 5: ... MANUAL 5 CONTROLS ANTENNA CONNECTOR COVER RUBBER SEAL PUSH TO TALK SQUELCH PRIVATE CHANNELS CHANNEL SET CH 16 SCAN MEMORY DUAL WATCH TRIPLE WATCH DOWN HI LO POWER KEY LOCK WEATHER ALERT UP DISPLAY VOLUME ON OFF WX UIC ...

Страница 6: ...r Alert SCAN Scan Priority Scan MEM Memory Mode Save Delete Memory Channel Up Down Channel Up Down Fast Up Down CH UIC Private Channel Band Selection SQL Squelch Level Setting ROTARY CONTROL Volume Power On Off and Adjust Volume RX SIGNAL TX POWER PRIORITY SCAN DUAL WATCH SQUELCH LEVEL KEY LOCK US BAND INTERNATIONAL BAND CANADIAN BAND TRIPLE WATCH WEATHER ALERT CHANNEL DESIGNATORS MEMORY WEATHER C...

Страница 7: ...o will switch to the weather channels and the WX icon will appear Weather channels are numbered 01 10 and are selected using the or keys To return to the normal communications channels briefly press the WX key again NOTE Weather channels provide a receive only weather information service in and around the US and Canada You cannot transmit on the weather channels Weather Alert Function US Canada Wh...

Страница 8: ...gain The displayed channel will be stored as your new second priority channel HI LO POWER Briefly press the key to toggle high or low transmitter power The display will show HI or LOW to confirm the selected power setting NOTE Some channels may be permanently limited to HI or LOW power by default If any of these channels are selected you will not be able to change the power setting for that channe...

Страница 9: ...s To quickly determine which channels are stored in the Memory 1 Briefly press the key MEM will appear to the left of the Channel display 2 Press the or keys to quickly step through the Memory channels Only channels stored in the Memory will be displayed 3 To exit from the Memory channels briefly press the key again MEM will disappear from the display NOTE You cannot add or remove channels from th...

Страница 10: ...ormal operation will be restored once the PTT is released ATIS OPERATION ATIS stands for Automatic Transmitter Identification System ATIS is used to identify a ship or vessel that has made a radio transmission The identity of the vessel is sent digitally each time the radio operator releases the PTT after transmitting ATIS is generally used in the inland waterways of Europe and is only available w...

Страница 11: ...io should be returned to GME for service to ensure the waterproof integrity of the radio is maintained To Charge the Battery Pull the connector cap on the top panel between the Volume control and the antenna to expose the charging socket Plug the supplied AC adaptor into the 240V power then connect the adaptor s charger plug into the socket on the top of the radio While the charger is connected th...

Страница 12: ...ess Safety and Calling 17 156 850 156 850 X Intership and On board Communications at 1W only 4 18 156 900 161 500 Public Correspondence Port Operations and Ship Movement 19 156 950 161 550 Public Correspondence Port Operations and Ship Movement 20 157 000 161 600 Public Correspondence Port Operations and Ship Movement 21 157 050 161 650 Public Correspondence Port Operations and Ship Movement 22 15...

Страница 13: ... 425 X Port Operations and Ship Movement Intership channels are for communications between ship stations Intership communications should be restricted to Channels 6 8 72 and 77 If these are not available the other channels marked for Intership may be used Channel 70 is used exclusively for Digital Selective Calling DSC and is not available for regular voice communications NOTES 1 Channel 06 may al...

Страница 14: ...156 700 156 700 X Port Operations VTS in selected areas 15 156 750 Environmental Receive only Used by Class C EPIRBs 16 156 800 156 800 X International Distress Safety and Calling Ships required to carry radio USCG and most coast stations maintain a listening watch on this channel 17 156 850 156 850 X State local govt maritime control 18A 156 900 156 900 X Commercial 19A 156 950 156 950 X Commerci...

Страница 15: ...rcial Intership only 73 156 675 156 675 X Port Operations 74 156 725 156 725 X Port Operations 77 156 875 156 875 X Port Operations Intership only 78A 156 925 156 925 X Non Commercial 79A 156 975 156 975 X Commercial Non Commercial in Great Lakes only 80A 157 025 157 025 X Commercial Non Commercial in Great Lakes only 81A 157 075 157 075 X US Government only Environmental Protection Operations 82A...

Страница 16: ...re reserved as guard bands for Channel 16 and are not available for regular voice communications Note that the letter A indicates simplex use of the ship station transmit side of an international duplex channel and that operations are different than international operations on that channel Some VHF transceivers are equipped with an International US switch for that purpose A channels are generally ...

Страница 17: ...l BCC area May be used to communicate with aircraft and helicopters in predominantly maritime support operations 10 156 500 156 500 X X X IS SS C NC S SM Commercial BCC area May also be used for communications with aircraft engaged in coordinated search and rescue and antipollution operations 11 156 550 156 550 X X X IS SS C NC SM VTS BCC area Also used for pilotage purposes 12 156 600 156 600 X X...

Страница 18: ...arine Broadcast CMB service 22A 157 100 157 100 X X X X X X X X IS SS C NC For communications between Canadian Coast Guard and non Canadian Coast Guard stations only 23 157 150 161 750 X X SS PC None 23B 161 750 X S Continuous Marine Broadcast CMB service 24 157 200 161 800 X X X X X X X X SS PC None 25 157 250 161 850 X SS PC Also assigned for operations in the Lake Winnipeg area 25B 161 850 X S ...

Страница 19: ...ure craft BCC area 68 156 425 156 425 X X X X X X X X IS SS NC For marinas yacht clubs and pleasure craft 69 156 475 156 475 X X X X X X X IS SS C NC Commercial fishing only EC area Pleasure craft BCC area 70 156 525 156 525 Digital Selective Calling for Distress Urgency Safety and Calling All Areas Voice communications prohibited 71 156 575 156 575 X X X X X X X S IS SS SM C NC Ship Movement BCC ...

Страница 20: ...e only 83A 157 175 157 175 X X X IS SS DFO Canadian Coast Guard and other Government agencies 83B 161 775 X X X S Continuous Marine Broadcast CMB Service 84 157 225 161 825 X SS PC None 85 157 275 161 875 X X X X SS PC None 86 157 325 161 925 X SS PC None 87 157 375 161 375 X X X X IS SM NC Port operation and ship movement EC area Pleasure craft BCC area 87B 161 975 161 975 X X X X X X X X AIS Aut...

Страница 21: ...c Correspondence Inland PRA Inland Waters of MB SK and AB AIS Automatic Ship Identification VTS Vessel Traffic Services SPECIFICATIONS GENERAL Frequency Range 156 025 to 163 275 MHz Number of Channels 56 International 52 US 59 Canadian 10 Weather Oscillator PLL Modulation FM Channel Spacing 25 kHz Frequency Stability 5 PPM Standard Operating Temperature 20 C 55 C Nominal Working Voltage 7 4 V DC w...

Страница 22: ...ious Response rejection CH16 80 MHz to 1 GHz 70 dB Conducted Spurious Emission 70 dB Scan Time per Channel 200 ms RX Current Standby 185 mA Max Audio Power 380 mA TRANSMITTER Output Power High 5W Low 0 8W Frequency Tolerance 5 PPM Max Modulation 5 kHz Conducted Spurious Emission 56 dB Audio Distortion 3 kHz Dev 5 Conducted Spurious Emission 56 dB TX Current High Power 1 6 A Low Power 0 9 A Specifi...

Страница 23: ...placement parts for the remainder of the period of warranty for the goods into which they are incorporated 2 3 To the extent permitted by law our sole liability for breach of a condition warranty or other obligation implied by law is limited a in the case of goods we supply to any one of the following as we decide i the replacement of the goods or the supply of equivalent goods ii the repair of th...

Страница 24: ...m misuse accident impact or neglect e goods improperly installed or used in a manner contrary to the relevant instruction manual or f goods where the serial number has been removed or made illegal 4 Warranty period 4 1 We provide the following warranty on GME and Kingray products No repair or replacement during the warranty period will renew or extend the warranty period past the period from origi...