background image

PA G E   4  

i n s t r u c t i o n   m A n uA l  

4 0 6   m H Z   P l B

Phone: +64 4 577 8033 . Fax: +64 4 577 8041 
Email: 406registry@maritimenz .govt .nz

Ensure information is current . notify the appropriate 
authority if ownership of the beacon is transferred .

other areas

 - Please contact your country Distributor 

as shown on page 8 of this manual . if you have a beacon 
coded with a foreign country code, or if you do not know 
what country code has been used, then you will need 
advice, please contact the relevant authority on one of the 
numbers shown above or visit:  
www .cospas-sarsat .org/BeaconscodingGuideGeneral/poc .htm

PrEvENTiNg aCCidENTaL aCTivaTiON

the signal from a PlB is regarded by authorities as an 
indication of distress and is given an appropriate response . 
it is the responsibility of every owner of a PlB to ensure 
that it is not activated unintentionally or in situations that 
do not justify its use .

most cases of accidental transmission result from poor or 
inappropriate storage or failure to totally disable an old 
model beacon before disposal . 

the need to treat emergency beacons responsibly cannot 
be too highly emphasised .

the mt410/410G will not commence transmitting until 
approximately 60 seconds after activation, providing a 
period of audible and visual warning . if you hear the 
beacon beeping while it is being carried or stowed, you 
may still be able to deactivate it during this time period 
without actually transmitting a distress signal . if in doubt, 
report the incident to your local authorities just in case .

to minimise the possibility of accidental activation, PlB 
owners are urged to pay careful attention to the  
following points:
1 .  Follow the self-testing procedures

2 .   Educate your travelling companions on how and when 

to correctly operate your PlB

3 .   Avoid stowing the PlB where it will be subjected 

to continuous direct sunlight . this could cause the 
beacon’s internal temperature to exceed the maximum 
storage temperature of +70°c . long term stowage 
under these conditions could result in reduced battery 
life, poor performance or degradation of the plastics 
due to excessive u .v . light .

4 .   Do not allow children to interfere with the PlB .

contacts for reporting activations

if you suspect that a PlB has been activated inadvertently, 
you must turn it off and report it immediately to your 
national Authority‘s rescue  co-ordination centre to 
prevent an unnecessary search . 

When reporting you should include the following:

1 .   your PlB’s 15 character unique identifier number 

(uin), which is marked on the unit body .

2 .  Date, time and duration of activation .

3 .  cause of activation .

4 .  location at time of activation .

search and rescue authorities will not penalize an 
EPirB owner or operator in cases of genuine accidental 
activation .

contact numbers:

  Australia: 1800 641 792 
  new Zealand: 0508 472 269 
  united states of America: (800) 323 7233 
  united Kingdom: 01326 317 575

baTTEriES & maiNTENaNCE

the mt410 and mt410G PlBs are fitted with the very 
latest in high capacity battery technology . these batteries 
are able to operate within a temperature range of -20°c 
to +55°c .

the full operational capability of your beacon may not 
be available if the batteries fitted have exceeded their 
replacement date, as shown on the body of the unit .  
Prior to reaching this date, make arrangements to have 
your mt410/mt410G returned for service .

note:

 PlB maintenance operations, including battery 

replacement, require that the beacon be returned to a 
manufacturer approved service facility . A list of authorised 
service centres can be found on: www .gme .net .au .  
the replacement of batteries due to expiry or usage is not 
covered by the product‘s Warranty .

mt410/mt410g batteries are not user replaceable.

Although the mt410/410G are otherwise maintenance 
free, routinely following these few simple steps will help 
ensure that your beacon will be operationally ready if  
called upon:

1 .  test the PlB at the recommended interval .

2 .  confirm the sAFEty sEAl has not been broken .

3 .   check that the batteries have not passed their 

replacement date . 

4 .   inspect the mt410/410G for physical damage  

or deterioration . 

5 .   Keep the unit clean by wiping over with a damp cloth 

(warm water and mild detergent are suitable), then dry .

Содержание accusat MT410

Страница 1: ...PAGE 1 instruction manual 406 MHZ PLB I N S T R U C T I O N M A N U A L...

Страница 2: ...ket Series Personal Locator Beacon PLB The GME Accusat Pocket MT410 and GPS equipped Accusat Pocket Pro MT410G are the most advanced 406 MHz digital satellite beacons available today Using new digital...

Страница 3: ...ellites are able to store the beacons position and digital message no matter where in the world it is received These details are then relayed to the next LUT that comes into range giving the 406 MHz s...

Страница 4: ...ult in reduced battery life poor performance or degradation of the plastics due to excessive U V light 4 Do not allow children to interfere with the PLB Contacts for Reporting Activations If you suspe...

Страница 5: ...d note that distress signals are not radiated as part of this test 4 If no satellites are found after a predetermined time the repetitive flash and beep will stop This may indicate a fault with the GP...

Страница 6: ...l and the unique personal identifier to the COSPAS SARSAT satellite system After 6 seconds the MT410G will continue to beep and pulse the light 20 21 times per minute deactivating the MT410 410G 1 Usi...

Страница 7: ...ry only Method non user replaceable Battery Chemistry LiMnO2 0 49 g Lithium per cell Battery 2 electronically isolated batteries Configuration consisting of 2 cells type CR17345 PHYSICAL Operating 20...

Страница 8: ...info gme net au Owner Details Name Address Tel UIN Hex ID Distributed by Australia 24 Hour Emergency Contact Phone 1800 641 792 or International 61 2 6230 6811 New Zealand 24 Hour Emergency Contact Ph...

Отзывы: