background image

2

Contents

Warranty Power Tools

Whilst every effort is made to ensure your complete 

satisfaction with this tool, occasionally, due to the mass 

manufacturing techniques, a tool may not live up to our 

required level of performance and you may need the 

assistance of our service department.
This product is warranted for a 2-year period for home 

domestic use from the date of the original purchase. 

If found to be defective in materials or workmanship, 

the tool or the offending faulty component will be repaired 

or replaced free of charge with another of the same item. 

A small freight charge may apply. Proof of purchase is 

essential. We reserve the right to reject any claim where 

the purchase cannot be verified.
This warranty does not include damage or defects to the 

tool caused by or resulting from abuse, accidents, 

alterations or commercial or business use. It also does not 

cover any bonus items or included accessories. Only the 

power tool is covered under this warranty. 
With continuing product development, changes may have 

occurred which render the product received slightly 

different to that shown in this instruction manual.
Please ensure that you store your receipt in a safe place.
Conditions apply to the above warranty. For full details of 

the warranty terms and conditions please refer to our 

website – 

www.gmcompany.com

For prompt service we suggest you log your service 

request online - www.gmcservice.com.au, should you 

not have access to the internet, please contact our 

service department on 1300 880 001 (Australia) 

or 0800 445 721 (New Zealand). 

Warranty 

2

Warning labels explained 

3

Introduction 

4

Environmental protection 

4

Description of symbols 

4

Specifications 

4

General safety rules 

5-6

Additional safety rules for air compressors 

6-7

Unpacking 

8

Components 

8

Know your product 

9

To start the air compressor 

10

Operating the air compressor  

10

Stopping the air compressor 

11

Assembly - Included Accessories 

11

Operating the quick change blow gun 

11

Connecting the inflation needle  
to the quick change blow gun 

12

Connecting the tapered hose fitting 
to the quick change blow gun 

12

Connecting the tyre inflator 

13

Troubleshooting 

13-16

Maintenance 

16

General inspection 

16

Cleaning 

17

Power cord maintenance 

17

Содержание MOC6L

Страница 1: ...1 6LT OIL LESS COMPRESSOR MOC6L INSTRUCTION MANUAL Black Cyan Magenta Yellow Code MOC6L IM Date 070620 Edition 02 Op MM ...

Страница 2: ...anges may have occurred which render the product received slightly different to that shown in this instruction manual Please ensure that you store your receipt in a safe place Conditions apply to the above warranty For full details of the warranty terms and conditions please refer to our website www gmcompany com For prompt service we suggest you log your service request online www gmcservice com ...

Страница 3: ... relief valve daily Refer the instruction manual To prevent build up of condensation open drain cock daily Unit starts automatically Switch off power supply remove plug relieve air pressure prior to commencing service tasks Read instruction manual prior to starting unit This equipment operates from AC mains only Ensure mains outlet is adequately rated for this unit High voltage used on this equipm...

Страница 4: ... 5 2 CFM Introduction Your new GMC power tool will more than satisfy your expectations It has been manufactured under stringent GMC Quality Standards to meet superior performance criteria You will find your new tool easy and safe to operate and with proper care it will give you many years of dependable service CAUTION Carefully read through this entire Instruction Manual before using your new GMC ...

Страница 5: ...refrigerators There is an increased risk of electric shock if your body is earthed or grounded c Do not expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords incre...

Страница 6: ...result in a hazardous situation 5 Service a Have your power tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the power tool is maintained Additional safety rules for air compressors WARNING Before connecting a tool to a power source mains switch power point receptacle outlet etc be sure that the voltage supply is the same as that...

Страница 7: ...e switch Drain the moisture from the tank daily It will help prevent corrosion Pull the ring on the safety valve daily to ensure that it is operating properly and to clear any possible blockages Keep the compressor at least 300mm from the nearest wall to ensure adequate ventilation for cooling purposes Before transporting the compressor make sure that the pressurized air is bled from the tank and ...

Страница 8: ...particles into the air Do not attempt to catch the air line but immediately keep bystanders well clear Disconnecting the remaining hose from the quick release fitting on the unit will automatically shut off the air supply Turn off the compressor at the On Off rocker switch Unpacking Due to modern mass production techniques it is unlikely that your GMC Power Tool is faulty or that a part is missing...

Страница 9: ...nect regulated outlet valve 9 Regulating knob 10 Safety valve 11 Tank pressure gauge 12 Regulated outlet pressure gauge 13 Drain cock 14 Power cord storage 15 Blow gun 16 Blow gun adaptor 17 Tapered inflation fitting 18 Tire chuck 19 Inflation needle 20 Nitto fitted air hose coil 21 1 4 Nitto male plugs adaptors X2 1 2 3 6 7 8 9 10 11 12 21 15 19 18 16 20 17 13 14 5 4 ...

Страница 10: ... persons within the area 9 To stop the compressor push the yellow On Off 1 switch to the off setting Operating the air compressor 1 The pressure in the tank is controlled by the action of a pressure switch When the set maximum pressure is reached the pressure switch activates and the motor is switched off The pressure then decreases as the air is used by the connected tool until the set minimum pr...

Страница 11: ... tank Fig G or open the drain cock 13 to release the pressure from the tank Note Always shut off the compressor after use and before servicing WARNINGS 1 Never attempt to remove any part of the compressor whilst the tank is under pressure 2 Never attempt to remove any electrical component whilst the compressor is connected to the power supply Switch off the power and remove the electrical plug 3 D...

Страница 12: ...ou are using the gun Never allow debris to be blown in the direction of another person or other objects Use safety glasses a face or dust mask and appropriate clothing for the task being undertaken Never apply the outlet of the air gun against a person s body Never look down the air outlet hole of the gun Connecting the inflation needle to the quick change blow gun In order to use the inflation ne...

Страница 13: ...ou are inflating for reference as to the recommended maximum air pressure requirement DO NOT EXCEED the maximum pressure ratings on the tyre you are inflating IMPORTANT The tyre inflator should only be used for its intended purpose to inflate tyres Do not discharge air through the inflator without it being fitted to a tyre Never apply the outlet of the tyre inflator against a person s body Never l...

Страница 14: ...ce Insufficient pressure or decreased outlet capacity Motor running too slow Use authorised service centre to check and repair if necessary Leaking safety valve Use authorised service centre to repair or replace the switch Leaking pipe Use authorised service centre to check and repair if necessary Damaged gasket Use authorised service centre to check and repair if necessary Damaged or carbon coate...

Страница 15: ...and tool to perform the task 3 Purchase a suitable air compressor from the GMC range that will run the required tool Drain cock may not be fully closed Check the drain cock to ensure it has been fully closed If not tighten Safety valve fully leaking Check out the condition of the safety valve If the valve is leaking immediately shut off the compressor and cease using Have the unit serviced checked...

Страница 16: ...day of operation check daily the operation of the safety valve 10 This check should be performed when the tank contains close to max pressure To check the valve pressurise the tank and pull the ring OUTWARDS on the safety valve Air should discharge from the valve Release the ring of the safety valve When the ring is released the air discharge must stop WARNINGS Safety glasses must be worn when per...

Страница 17: ...eeds cleaning wipe it with a soft damp cloth A mild detergent can be used but nothing like alcohol petrol or other cleaning agent 5 Never use caustic agents to clean plastic parts CAUTION Water must never come into contact with the tool Power cord maintenance Only an authorised service centre should replace the cordset or carry out other repairs If the cordset is damaged or worn have it repaired o...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...ew Zealand 7am 7pm 7days a week AEST Please note that if repair or replacement is required you must provide a valid original purchase receipt You will need the following details at hand to log your service request Personal details First Last name address pick up address contact phone numbers email address Product details Product number date of purchase retailer bought from State postcode receipt n...