OSPREY WATER SOFTENER
INSTALLATION AND ASSEMBLY
INSTRUCTIONS
PAGE 3
IMPORTANT:
Check for leaks at ALL joints and connections after turning on the mains water.
After 3 hours check for leaks at all joints and connections.
We recommend a further check after 24
hours.
Once installed then please check and top up the salt approx. every 2 weeks to ensure consistent
results are achieved from the unit.
If you have any questions then please contact our technical department for clarification.
tel : 01403 701970
To set the programming on your new softener please fol-
low these simple steps:
Push the programme button
—
top left
Scroll down using the down arrow until you get to the time
setting
Push the set button (square, bottom left) and the hours
will flash
Then using the up and down arrows select your current
time of day
Press the set button
Repeat this process to set the minutes
Press the set button again
Press the down arrow to show regeneration time
–
This is
pre
-
set to 2am but please adjust as you wish
Scroll through the other settings until it says English lan-
guage and press the programme button to finish set up
Once the programme is complete the unit needs to be commissioned
Open the inlet water
Turn the regeneration knob to the white dot until the valve starts to rotate on its own
Once the valve stops rotating the water will start to run to drain
After Approximately 2 Minutes push the set button again.
Once the valve stops moving again push the set button again
Once the valve stops moving again water will again run to drain
Leave to automatically finish the cycle this should take approximately 10 minutes
Once finished open up the outlet valve and your unit is now in service