Functional description

The HZ-lock VB 19000 multipoint locking system for burglary-resistant leaf doors fulfils all desired func-
tions and requirements. When the door is closed by the door closer, the latch first engages in the striking 
plate and positions the door in the locked position, whereupon the three bolts (normally one bolt at the 
bottom, centre, and top) automatically extend (automatic locking). When in the extended state, the bolts 
are blocked from being pushed back into the lock case. The hardened lock case impedes attempts to drill into 
the case. 

In the basic state, the lever handle on the outside is disengaged. The coupling of the lever handle to the lok-
king mechanism normally takes place with the integrated electric magnet which can be controlled with any 
access control system. As long as the magnet is powered, the lock latch and the bolt are withdrawn when 
the handle is actuated. In the process, the bolts remain in place in each retracted position in order to open, 
even if they are not entirely retracted with a wide rebate gap. If there is a power failure, or for emergency 
opening by rescue workers, the lever handle can also be coupled by means of the security cylinder with the 
appropriate security key. 

All required control and monitoring contacts are integrated in the HZ-lock VB 19000:
• Separate potential-free lock contacts on the inside and outside lever handles
• Potential-free switchover contact for mechanical handle coupling via the cylinder
• Bolt position contact and leaf position contact for monitoring of the correct locking (the evaluation of

these contacts is strongly recommended).

The lock has satisfied testing requirements at the Material Testing Office in Dortmund in accordance with 
DIN 18251-3 Class 4, and thereby fulfils requirements on a lock for increased burglary resistance and high 
usage frequency. It has a certificate as an emergency exit lock in accordance with EN 179 with Glutz security 
fittings for doors weight up to 400 kg. 

Suitable security fittings with suitable divided handle spindles must be used for doors for escape and rescue 
route applications. Use of the Glutz twin glide easyfix® bearing is preferred.

Optional: electrical release block for locking

There is a second magnet arranged at the top in the lock case of the main lock which can be used to suppress 
the extension of the three bolts as long as voltage is applied to the coil of the magnet.

After voltage is applied to this additional electric magnet, the three bolts and the latch are retracted with 
the coupled outside lever handle or the inside lever handle. Then when the doors close, only the lock latch 
engages and the three bolts remain retracted. If the current supply to the magnet is interrupted, the bolts 
extend when the door is closed.

An electric strike is used for doors with an automatic drive as a counterpiece to the lock case. 

Solenoid coil: 12 or 24 VDC, 100% duty ratio, 4.8 watts
N.B. This version in does not correspond to the General appraisal certificate.

Содержание HZ-lock VB 19000

Страница 1: ...MA 10101 Assembly and Maintenance Instructions HZ lock VB 19000...

Страница 2: ......

Страница 3: ...sembly instructions 14 HZ lock VB 19000 multipoint lock 15 Assembly requirements 16 Switching the panic function 18 Removing the panic function 19 Check of electrical feedback 19 HZ lock VB 19000 with...

Страница 4: ...ly maintenance care and disposal Please read this manually carefully and attentively prior to installation Save this manual for as long as the product is in use and pass it along to the next user The...

Страница 5: ...installed at a height of 900 mm to 1100 mm above the surface of the finished floor with the door closed If the majority of the door users are small children a lowering of the actuation bar height shou...

Страница 6: ...150 N to the lever handle in the actuation direction Do not actuate the lever handle and key at the same time Do not drill in the lock area of the door leaf with installed lock Do not use force to st...

Страница 7: ...must be replaced Do not carry the door leaf by the lever handle Locks must be lubricated at least 1 x per year according to the manufacturer s specifications use grease or non resinating oil Once ther...

Страница 8: ...ial free switchover contact for mechanical handle coupling via the cylinder Bolt position contact and leaf position contact for monitoring of the correct locking the evaluation of these contacts is st...

Страница 9: ...ility for door elements up to RC4 Three blocked bolts with 20 mm forward feed Hardened lock case anti drilling protection Hardened bolts Hardened connecting bars for the additional bolts Connecting ba...

Страница 10: ...pair the automatic locking Therefore moni toring the correct locking is recommended for automatically locking locks HZ lock VB 19000 locks are normally equipped with panic function In this process the...

Страница 11: ...maintenance The lock latch control latch and the bolts must be lubricated with suitable lubricants e g MOTOREX 176 GP multi purpose grease at least twice annually or more frequently depending on use...

Страница 12: ...a matching system which has been te sted and approved according to the appropriate standards Therefore the HZ lock VB 19000 may only be used in combination with a matching striking plate from Glutz I...

Страница 13: ...th three bolts every time it is closed The key rotation in the cylinder is therefore unnecessary However in order for the automatic blocking to take place in a fault free manner the bolts and the latc...

Страница 14: ...ight pressure and carefully pull apart without bending Monitoring contacts for 1 Bolt position 2 Leaf position 3 Lever handle contact 4 Cylinder contact Reversible panic direction EN 179 for door leaf...

Страница 15: ...coil voltage 12 or 24 VDC Control and handle contacts locking contacts Monitoring contacts Inside outside lever handle Door position Door locking Entry with key Quality standard RC4 in accordance with...

Страница 16: ...ower lock section and the upper forend extension takes place by carefully pushing one of the two connecting bars of the forend extension into the guide grooves on the forend of the main lock until the...

Страница 17: ...te to drill the holes for the screw connection of the in side and outside plate is recommended The site fixing template is positioned on the lever handle and the cylinder cutout Drill from both sides...

Страница 18: ...does not fall into the lock case 5 The lever handle can now be released again 6 Rotate the lock handle follower now disengaged at the top 7 RemovetheroundstickerwithHZsymbolnexttothefollower whichwill...

Страница 19: ...st A clarifying telephone conversation is normally less expensive than a lock repair Check of electrical feedback The following are requirements for the correct function of the door monitoring bolt po...

Страница 20: ...ck control In an emergency the escape door strike can be unlocked by the fire alarm system or disengaged with the emergency button The cylinder contact installed in the lock can be used for the unlock...

Страница 21: ...lever handle is disengaged and the door can no longer be ope ned with the inside lever handle In order to guarantee the ability to exit despite this an exit button is arranged on the inside on a prote...

Страница 22: ...striking plate brass case with adjustable magnet position 2698 Flat permanent magnet with cap profile for striking plates made of non magnetic stainless steel 2697 10 mm round magnet height 5 mm For d...

Страница 23: ...9 169 209 209 26 324 190 190 190 209 97 24 2 8 12 11 6 128 209 269 209 209 A B 2050 773 1005 2150 873 1105 2250 973 1205 Glutz AG Massblatt HZ Lock mit Tagesfunktion Zsm 23 05 13 X X X X 24 Auxiliary...

Страница 24: ...llungs kontakt Zusatzmagnet f r Tagesbetrieb Option 25 Connection diagram white 1 brown 2 green yellow 4 grey 5 pink 6 blue 7 red 8 black 9 violet 10 grey pink 11 red blue 12 white green 13 brown gree...

Страница 25: ...ntact closes with an actuation of the lever handle pointing to the left For example signalling of the authorised exit on the monitoring system 9 black NO 30 300 Lever handle con tact This contact clos...

Страница 26: ...1 The control latch is jammed 2 There is lubricant or oil spray in the lock 3 The control latch is bent 1 Lightly grease and move the control latch by pressing the main latch in slightly 2 Send the lo...

Страница 27: ...3 Send the main lock in for repairs 4 Fit an original striking plate or ma gnet 2 2 The Electrical connection dis engaging switchover contact does not function only for locks with this option until Ju...

Страница 28: ...r doors on escape routes fulfilled 70N unloaded Durabilty of ability to release against aging and degradation for doors on escape routes fulfilled 200 000 cycles Initial test carried out and Classific...