Preventive Maintenance
1.
To prevent the clogging of the glue gun, keep the feed mechanism and melt chamber free from
dirt and other foreign debris. Store unused glue sticks in a clean environment.
2.
Do not pull glue stick from the back of the glue gun
. The feed mechanism may be damaged or
impaired. If you desire to change types of glue, cut off the protruding end and push the remainder
through with the new type of glue.
3.
Do not lay heated gun on its side. Keep the heated gun in an upright position with nozzle pointed
down.
4.
If melted glue has escaped from the melt chamber entrance and is interfering with the feed
mechanism; allow gun to cool, and gently remove the obstructing glue.
5.
Replace the nozzle if glue drips excessively. Do not attempt to change nozzle when glue is cold.
To change, the gun must be heated until the glue is softened enough to remove nozzle. Use
gloves with the proper wrench to remove the old nozzle. (USE CAUTION) Install the new
adapter G25E01-003 and a new nozzle G25E01-004. Tighten only until snug.
Do not over
tighten.
6.
Keep outside of glue gun clean.
7.
Only use approved 7/16″ diameter stick glue with this gun.
Champ Stick
TM
400 Features
Glue stick direction
Stroke adjustor
Power Cord (120v)
ON/OFF switch
Trigger
Temperature adjustor