GLP Joy 300 Скачать руководство пользователя страница 14

  

 

GLP 

Š

 German Light Production 

(V2.1)

 

14

 

5 Programming 

the 

J

J

O

O

Y

Y

-

-

3

3

0

0

0

You can program the 

J

J

O

O

Y

Y

-

-

3

3

0

0

0

0

 in a standalone program within 25 steps. This program 

can run automatically after turning on the unit. This means you need a DMX Controller 

for programming but not for running the stand alone program. 

5.1  Engage the Program Mode 

Normal - Mode:

 Receive standard DMX signal. 

Receive - Mode:

 The scanner receives DMX signals for programming and stores 

the steps. 

Send - Mode:

 The scanner works stand alone and sends DMX signals to other 

scans. 

a) Engage at the

 

J

J

O

O

Y

Y

-

-

3

3

0

0

0

0

 

 

Press the Menu key once. 

P_n_

. You are now in the Normal – Mode. 

Change with the Cursor key to the Receive – Mode 

P._r_

 or further to the Send 

– Mode 

P._S_

 

Press the Menu key again to confirm the changes. 

b) Engage with a DMX Controller 

Look at the channel selection overview table. 

5.2  Write a program 

You must be in the Receive- or Send – Mode to program the 

J

J

O

O

Y

Y

-

-

3

3

0

0

0

0

.

.

 In this 

mode the DMX Channels 13, 14 and 15 are activated. 

Procedure: 

1)  Activate the Receive- or Send - Mode. 

2)  Set Channel No.13 to 

“Set DMX-Values”

 (DMX 16..254). 

3)  Choose the programstep with DMX Channel No.15. 

4)  Set your DMX adjustments with the DMX Channels No.1..12. 

5)  Choose the Next Time or the Audio control with DMX Channel No.14. 

6)  Save the step with DMX Channel No.13  

xx 

Æ

 255 

Æ

 00.

 

7) etc. 

Содержание Joy 300

Страница 1: ...Instruction Manual From Version 1 23 email service glp de Internet http www GLP de...

Страница 2: ...GLP German Light Production V2 1 2...

Страница 3: ...Menu Field 8 3 1 Adjust the DMX Address 8 3 2 Read out the Running Time of Lamp and Unit 9 3 2 1 Lamp Time 1 9 3 2 2 Lamp Time 2 9 3 2 3 Life Time 9 3 3 The CODE Level 9 3 4 The Test Level 10 3 5 Temp...

Страница 4: ...duction V2 1 4 6 2 How to change the lamp 15 7 Change the Gobos 16 7 1 Safety Rules 16 7 2 How to change the Gobos 16 8 Maintenance the J JO OY Y 3 30 00 0 17 8 1 Mirror and Optical System 17 9 Techni...

Страница 5: ...GLP German Light Production V2 1 5 1 Introduction Illustration 1 1...

Страница 6: ...AC before you open the J JO OY Y 3 30 00 0 Please do not touch the Bulb if you are not absolutely sure it is cold Danger of BURNING 5 The J JO OY Y 3 30 00 0 is provided with a protecting switch whic...

Страница 7: ...ect them with the eyelet see Drawing 1 1 and check the tight fit 2 3 Connectors 2 3 1 AC Connectors 230 Volt 50 Hz 1 8AT power compensated 115 Volt 60 Hz 3 6AT power compensated Please see printing on...

Страница 8: ...ta buttons After pushing the Cursor button the upcounting speed increases to a multiple You can see that at the three decimal dots Pushing the Cursor button again to get to the slow speed Confirm the...

Страница 9: ...me 1 The current lamp time is shown alternating with LA 1 This time can be cleared by pressing the Data and Data keys at the same time 3 2 2 Lamp Time 2 The total lamp time is shown alternating with L...

Страница 10: ...mes Start the Selftest program by pressing the Cursor key The lamp will be started automatically and a selftest procedure with 8 steps will run To leave the selftest press the Menu key again 3 5 Tempe...

Страница 11: ...6 44 47 2C 2F 17 18 Color 6 48 51 30 33 19 20 Color 6 Color 7 52 55 34 37 20 21 Color 7 56 59 38 3B 21 22 Color 7 open 60 63 3C 3F 23 24 Mix Color 1 64 67 40 43 25 26 Mix Color 2 68 71 44 47 26 27 Mix...

Страница 12: ...or correction filter 96 111 60 6F 38 43 Prism 5 face 112 127 70 7F 44 50 Audio Prism change slow 254 FE 99 Audio Prism change fast 255 FF 100 11 Special No function 0 15 00 0F 0 6 Gobo wipe 10 slow fa...

Страница 13: ...5 F8 FF 94 100 Lamp ON Shutter open 240 255 F0 FF 94 100 Lamp OFF Shutter close and Special channel 11 and Speed channel 12 0 15 0 10 X 255 0 00 0F 0 0A X FF 0 0 6 0 4 X 100 0 These channels are only...

Страница 14: ...OY Y 3 30 00 0 Press the Menu key once P_n_ You are now in the Normal Mode Change with the Cursor key to the Receive Mode P _r_ or further to the Send Mode P _S_ Press the Menu key again to confirm t...

Страница 15: ...6 1 Safety Rules Unplug AC power connection Allow to cool min 30 minutes Don t touch lamp with bare fingers Install the lamp with the filler to the right direction Distance between lamp and lens hold...

Страница 16: ...before you connect the AC power 7 2 How to change the Gobos Please look also Illustration 1 1 1 Open the two screws at the top plate 2 Remove the gobosprings with the help of an small screwdriver 3 C...

Страница 17: ...Use no strong detergents acid etc for cleaning the case 8 1 Mirror and Optical System Clean the J JO OY Y 3 30 00 0 optical system with a moistened cloth and a little cleaner Attention Never clean th...

Страница 18: ...Power compensated DMX 512 Standard Weight 16 kg Dimensions 600 x 175 x 265 mm 16 Bit Pan Tilt Pan movement 170 Pan movement 110 5 rotating and positioning Gobos 1 fixed Gobos 3 glass Gobos 10 Colors...

Страница 19: ...GLP German Light Production V2 1 19...

Отзывы: