background image

 

3

3

3

0

0

0

0

0

0

 

 

 

X

X

X

L

L

L

 

 

 

R

R

R

Z

Z

Z

 

 

 

R

R

R

G

G

G

B

B

B

 

 

GLP 

 German Light Products GmbH 

(Manual Version 1.2) / from Software Version 1.01/03/02)

 

16

 

Channel 

Function 

Time and Value 

DMX 

HEX 

 

Up-dimming then Shutter closing 
(random patterns)  

slow - fast 

48..79 

30..4F  19..31,5 

 

Shutter open then down-dimming 
(random patterns) 

slow - fast 

80..111 

50..6F 

32..43 

 

Up-dimming then down-dimming 
(random patterns) 

slow - fast 

112..143  70..8F 

44..56 

 

Strobe effect pause  

5s to 1s 

144..199  A0..C7 

57..77 

 

Strobe effect, slow - fast 

1 Hz .. 10 Hz 

200..239  C8..EF 

78..94 

 

Shutter open 

 

240...249  F0..F9  95..97,5 

 

RESET 

Min. 3 Sec. 

250 

FA 

98 

 

Shutter open  

 

251..255  FB..FF  99..100 

12) Dimmer-
 

coarse 

Dimmer  

0% - 100% 

0..255 

0..FF 

0..100 

13) Dimmer-
 

fine 

Dimmer - Low 

 

0..255 

0..FF 

0..100 

14) Zoom 

Steplessly adjustable Zoom   

10° - 26° 

0..255 

0..FF  

0..100 

 

1)

 The predefined colors can be used as start colors for the Rainbow effect.  First select a desired start 

color, then  activate the rainbow effect. All 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

3

3

0

0

0

0

 

 

X

X

L

L

 

 

R

R

Z

Z

 

 

R

R

G

G

B

B

 

 

will then begin from that 

color and execute the rainbow effect synchronously. Different 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

3

3

0

0

0

0

 

 

X

X

L

L

 

 

R

R

Z

Z

 

 

R

R

G

G

B

B

 

can have different start colors but will still execute the rainbow effect synchronously. If  you choose a 

color different from the ones marked with 

1)

 in the tables above the rainbow start-color will be red.  

 

2)

 Rainbow-effect Stop will pause this function. After resuming the rainbow-effect will be continued with 

the current color.  

 

3)

 The Rainbow-effect will run synchronously only if it is started from one of the predefined colors (see 

also 

1)

 before). 

 

Locking and unlocking the Control Panel 

You can lock and unlock the control panel by pressing the menu keys MODE & ENTER & UP at the 

same time.  

 

Additional shortcut features when switching on the fixture 

a)  1200Hz Mode (Hold down the UP- button during power ON)  

After  switching  on,  the fixture  the  LEDs  will  be  operated  with  a  Pulse Width  Modulation 

(PWM) of 1200Hz.  

In addition, all standard settings will be loaded (DMX start address [001], Normal Mode).  

 

b)  600Hz Mode (Hold down the DOWN- button during power ON)  

After  switching  on,  the fixture  the  LEDs  will  be  operated  with  a  Pulse Width  Modulation 

(PWM) of 600Hz.  

In addition, all standard settings will be loaded (DMX start address [001], Normal Mode). 

 

 

Содержание Impression 300 XL RZ RGB

Страница 1: ...Instruction Manual from Software Version 1 01 03 02 Manual Version 1 2 e mail service glp de Internet http www glp de...

Страница 2: ...3 3 30 0 00 0 0 X X XL L L R R RZ Z Z R R RG G GB B B GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 2 For your notes...

Страница 3: ...6 2 1 1 Mounting on the floor upright 7 2 1 2 Mounting in hanging position Head down 7 2 1 3 Mounting in sideway position 8 2 2 Securing the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9...

Страница 4: ...to secure and lock the tilt movement see also 1 1 4 LCD Display Menu data entry 5 Base with various connectors and Camlock mounting system Safety eyelets 1 2 4 5 3 base side 1 10 6 7 8 9 10 base side...

Страница 5: ...d the manufacturers warranty 6 Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay attention to possible hot parts of the...

Страница 6: ...ation and Installation 2 1 Mounting The I IM MP PR RE ES SS SI IO ON N 3 30 00 0 X XL L R RZ Z R RG GB B is fully operational whether it hangs or is mounted to a wall It can also be operated while sta...

Страница 7: ...sing the two Camlock quarter turn fasteners Line up and engage the camlock connectors from the floor stand into the base of the fixture and turn the two fasteners 90 to lock them Do the opposite to re...

Страница 8: ...available from GLP or one of their agents This mounting bar is fixed via the four camlock quick release connectors Two half couplers or clamps are then used to hang the mounting bar This technique is...

Страница 9: ...32mm Please see printing on the case for the correct mains supply Disconnect from the mains supply for changing the fuse and use only the above described micro fuse type 2 3 2 DMX USITT DMX 512 Standa...

Страница 10: ...blue Green Manual control for green DOWN UP Red Manual control for red Color Wheel Manual control for the color wheel Tilt Manual control for Tilt Y movement Zoom Manual control for Zoom Display Cont...

Страница 11: ...cally position feedback correction for Pan Tilt movement White Adjust Adjustments for a uniform white color white balance only in white mode Red Input for red adjustments DOWN UP Blue Input for blue a...

Страница 12: ...Tilt SelectsInverse Tilt on or off Reset RESET all functions 4 DMX Channel Sheet Normal Mode 14 DMX channels Channel Function Time and Value DMX HEX 1 PAN coarse 0 660 0 255 00 FF 0 100 2 PAN fine Hi...

Страница 13: ...ast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 255 F0 FF 95 100 10 Dimmer Dimmer 0 100 0 255 0 FF 0 100 11 Color No color temperature correction 0 0 0 temperature Continuous color temperature cor...

Страница 14: ...xists to likewise select these settings also in the display menu If the White Mode is set to ON the white balance is activated If the White Mode is set to OFF the RGB goes for the maximum light output...

Страница 15: ...ing then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 249 F0 F9 9...

Страница 16: ...nbow effect synchronously Different I IM MP PR RE ES SS SI IO ON N 3 30 00 0 X XL L R RZ Z R RG GB B can have different start colors but will still execute the rainbow effect synchronously If you choo...

Страница 17: ...ld up on or within the fixture If they do the fixture s light output will be significantly reduced and damages to the fixture may occur Regular cleaning will not only ensure the maximum light output b...

Страница 18: ...System Additive Color mixing LED Type 297x Luxeon Rebel High power LEDs Lifetime 50 000 h 105 red 96 green 96 blue LEDs wavelength optimized for maximum presentable color space Optical System High ef...

Страница 19: ...1 K Key code 10 L LED Class 2M 5 M Maintenance 17 Manual Version 1 Max Power Mode 14 Micro fuse 9 Mode key 9 Mounting 6 Mounting in hanging Position 7 Mounting in sidewise Position 8 Mounting on the F...

Страница 20: ...3 3 30 0 00 0 0 X X XL L L R R RZ Z Z R R RG G GB B B GLP German Light Products GmbH Manual Version 1 2 from Software Version 1 01 03 02 20...

Отзывы: