German Light Products®
Control menu layout
Fusion MBL40 User Manual Rev. A
25
10.
Control menu layout
Menus
Notes
DMX ADDR
1
- 512
Enter DMX address
STANDARD
– 2
DMX MODE
ADVANCED – 5
Select DMX control mode
CCT
2700K – 6500K in 100K steps
Set Color Temp for rotary
knob “Manual” position
MANUAL
BRI
000%-100% in 1% steps
Set Brightness / Dimmer for
rotary knob “Manual”
position
DIMCURVE
LINEAR,
THEATER, SQUARE,
SQINVERS
Set dimmer curve
DIMSPEED
FAST
, SMOOTH
Set dimming speed
PWM
10KHz,
12KHz
, 16KHz, 18KHz,
24KHz, 30KHz
Set LED refresh rate
NO DMX
BLACKOUT,
HOLD
, MANUAL
Set operation when DMX is
lost
SCRNTIME
01 MIN, 05 MIN, 10 MIN,
OFF
Set time for screen to turn
off
SCRNFLASH
ON,
OFF
Set screen to flash when
no DMX is present
SETTINGS
SCRNLOCK
01 MIN, 05 MIN, 10 MIN,
OFF
Set time for screen to lock
TIME CUR
00:00 (hh:mm)
Shows how long unit has
been powered for this
session
TIME TOT
000000 (hours)
Shows total run time of unit
TEMP LED
000 C
Shows LED temperature
FIRMWARE v1000
Firmware version
SERIAL 00001
Unit serial number
INFO
RDM UID
A0BC31 (example)
Last digits of unique
identifier in hexadecimal
TEST RUN
Press Enter to start test,
Menu or Enter to stop
DEFAULT LOAD
Press Enter to load default
settings, except DMX
Address and DMX Mode
SERVICE
CALIBRAT
See table below
Adjust the warm
white/cool white settings
for CCT values. You must
hold Enter for 5 seconds to
enter this menu.
Default settings are written in
BOLD type.
Содержание Fusion MBL40
Страница 1: ...Fusion MBL40 User Manual Software version 1 0...
Страница 37: ...Fusion MBL40 User Manual Rev A 37...