The “Manual” position of each switch selects the settings programmed using the MANUAL
Æ
CCT and MANUAL
Æ
BRI menu options. This allows you to set custom output levels if none
of the settings on the switches are suitable.
Note: The rotary switches are only effective when no DMX signal is received and the
SETTINGS
Æ
NO DMX option is set to MANUAL. If DMX is being received, that will always
override the settings on the rotary switches.
Behavior when the fixture is not receiving a DMX signal
You can set the fixture to react in three different ways if no DMX signal is present (if the
fixture is being controlled by DMX but the DMX signal stops, or if you apply power to the
fixture when no DMX signal is present):
●
Hold
sets the fixture to continue obeying the last DMX values it received. If the fixture is
powered up with no DMX signal, the fixture will remain in black out. This is the default
setting.
●
Blackout
sets the fixture to black out.
●
Manual
sets the fixture to output the current settings of the rotary switches, or the
MANUAL menu option when the rotary switches are set to “Manual” position.
These settings are available via SETTINGS
Æ
NO DMX on the fixture’s control panel and
using the
Control / Settings
DMX channel.
Display
The illuminated LCD display lets you change fixture settings when power is applied. See
Chapter 9 for more details.
Using the
Control / Settings
DMX channel or the SETTINGS
Æ
SCRNTIME option on the
fixture’s control panel you can set the display to automatically switch off when no buttons
are pressed for a time.
The display will flash when no DMX is being received. You can turn this feature off using the
SETTINGS
Æ
SCRNFLASH option.
Fixture information
The
Info
menu in the control panel gives access to items of information from the fixture’s
sensors and memory. You can check temperature sensor readouts, see total operating
hours counters, and see software version number, for example.
Factory defaults
You can customize fixture settings (DMX mode, Display Sleep time etc.) via DMX or using
the fixture’s control panel. Custom settings are stored after a power off/on cycle and after
a reset.
Using the fixture’s control panel option SERVICE
Æ
DEFAULT you can restore the settings to
the factory defaults. This reloads all the fixture’s factory default settings
except
DMX