background image

German Light Products® 

Safety 

 

EXO Spot 30 User Manual Rev. A 

 

7

 

● 

Use only Neutrik PowerCON TRUE1 cable connectors for AC mains power input at 

the fixture’s Mains IN connector and for relaying AC mains power from one fixture’s 

Mains OUT (Thru) connector to another fixture’s Mains IN connector. 

● 

Use minimum 14 AWG or 1.5 mm

2

 power input and relay cables that are minimum 

16 A-rated and temperature-rated to suit the application. In the USA and Canada 

the cables must be UL-listed, type SJT or equivalent. In the EU the cables must be 

type H05VV-F or equivalent.  

● 

Do not connect devices to power in a chain if the total maximum current draw of all 
the devices in the chain when added together will exceed the current rating of any 

cable or connector used at any point in the chain. The supplied power input cable 

is rated as follows: 

US power cable: 16 A, 14 AWG, UL-listed, E304117, SJT, 4.9 ft. 

EU power cable: 16 A, 1.5 mm

²

, H07RN-F, 1.5 m. 

Do not connect more than six (6) Fusion EXO Spot 30 fixtures to power in a chain at 
100-120 V, 60 Hz. 
Do not connect more than twelve (12) Fusion EXO Spot 30 fixtures to power in a 

chain at 200-240 V, 50 Hz. 

● 

The voltage and frequency at the Mains OUT socket are the same as the voltage 

and frequency applied to the Mains IN socket. Only connect devices to the Mains 
Out socket that accept this voltage and frequency. 

● 

Fusion EXO Spot 30 fixtures do not have a user-replaceable fuse. If you suspect that 

a fuse has blown, disconnect the fixture from power and send it to a technician 

authorized by GLP for repair. 

 

 

Fire safety and protection from burns 

● 

Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C / 104° F. 

● 

The surface of the fixture’s casing can reach up to 90° C / 194° F during operation. 
Avoid contact by persons and materials. Do not install the fixture in a location where 

there is a risk of accidental contact. Allow the fixture to cool for at least 20 minutes 

before handling 

● 

Keep the fixture well away from flammable materials. 

● 

Keep all combustible materials (e.g. fabric, wood, paper) at least 0.5 m / 20 in. 
away from the fixture. 

● 

Ensure that there is free and unobstructed airflow around the fixture.  

● 

Do not illuminate surfaces within 0.5 m / 20 in. of the fixture. The light output from the 

fixture is powerful enough to cause burns or fire in illuminated objects at very close 

range. 

● 

Do not stick filters, masks or other materials onto the fixture. Do not block the light 
output in any way. The front surface becomes hot during operation and can melt or 

Содержание Fusion EXO Spot 30

Страница 1: ...Fusion EXO Spot 30 User Manual Software version V1 0 00...

Страница 2: ...ed companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information...

Страница 3: ...rvice and Support 12 3 EXO Spot 30 overview 13 4 Installation 15 Permitted mounting options 15 Securing fixtures with a safety cable 15 Installing on a rigging truss or similar structure 16 Standing o...

Страница 4: ...l menu layout 29 Service Advanced menu 31 11 DMX control mode overview 32 12 DMX control channel layout tables 33 DMX Mode 1 Standard 33 13 Service 38 Cleaning 38 GLP Service and Support 38 14 Technic...

Страница 5: ...0 DMX Channel Index available for download from www glp de The Channel Index is a separate guide to the DMX control channel layout and DMX commands available All documents are available for download f...

Страница 6: ...nd on the fixture Refer all repairs and any service operation not described in this manual to a technician authorized by GLP The light source in this fixture must not be changed by the end user Read a...

Страница 7: ...frequency at the Mains OUT socket are the same as the voltage and frequency applied to the Mains IN socket Only connect devices to the Mains Out socket that accept this voltage and frequency Fusion EX...

Страница 8: ...persons near to or working on the fixture are not looking directly into the light output when the fixture lights up suddenly This can happen when power is applied when the fixture receives a DMX sign...

Страница 9: ...r Rigging clamps must be half coupler type that completely encircle the rigging truss chord If the fixture is installed in a location where it may cause injury or damage if it falls install as directe...

Страница 10: ...roduct warranty Avoiding damage from light sources and heat Do not point the front of the fixture towards the sun or other strong light sources Strong light can cause internal damage to the fixture me...

Страница 11: ...65 rating means that the item is protected against the entry of water from rain projections and low pressure jets as well as the entry of dust When assembling connectors and installing them on cable f...

Страница 12: ...or a suitably designed flight case to protect it from damage caused by shocks during transportation Release the tilt lock and support the fixture s head with the original packaging inserts or flight...

Страница 13: ...can be fitted to enable LumenRadio wireless control The fixture has a built in battery to allow the display to be operated for setup before mains power is connected The EXO Spot 30 can be used indoor...

Страница 14: ...2 Head 3 Tilt lock 4 Yoke 5 Control panel 6 Base 7 Rubber feet 8 Wireless indicator 9 Battery button 10 PowerCON TRUE1 input 11 Mode Esc button 12 Up button 13 Down button 14 Enter button 15 Optional...

Страница 15: ...tion and that meets all applicable codes and legal requirements Note the requirement to secure lighting fixtures with safety cables in temporary installations Permitted mounting options An EXO Spot 30...

Страница 16: ...ure 4 Fasten the safety cable through the slot B on the underside of the fixture base Check that the fixture is now secured Installing on a rigging truss or similar structure You can suspend an EXO Sp...

Страница 17: ...nd yoke of the fixture will not collide with any fixed objects as the fixture moves Ensure that the fixture has sufficient clearance to any adjacent surfaces or objects 5 Secure the fixture with a saf...

Страница 18: ...ernal auto sensing power supply accepts AC power at 100 240 V 50 60 Hz Do not connect the fixture to power at any other voltage or to an external dimmer The EXO Spot 30 does not have a power ON OFF sw...

Страница 19: ...more than six 6 EXO Spot 30 fixtures in total to power in one chain at 100 120 V 60 Hz Do not connect more than twelve 12 EXO Spot 30 fixtures in total to power in one chain at 200 240 V 50 Hz The po...

Страница 20: ...O Spot 30 has two 5 pin XLR sockets for IN and THRU connections to a DMX data link EXO Spot 30 fixtures support the USITT DMX 512A signal protocol They also support RDM Remote Device Management The 5...

Страница 21: ...TRUE1 mains power input connector supports hot plugging and connecting and disconnecting a live power cable is an option especially if you need to shut down power urgently but it is still good practic...

Страница 22: ...agenta Yellow control channels 8 10 or fixed color filters can be selected using Color 1 Cyan Color 2 Magenta Color 3 Yellow control channels 5 7 To set a fixed color you must have the corresponding v...

Страница 23: ...A 23 Gobo wheels The EXO Spot 30 has two gobo wheels Wheel 1 has 9 positions including open and the gobos are fixed non rotating Figure 6 Gobo Wheel 1 Wheel 2 has seven positions including open and th...

Страница 24: ...obe shutter A variety of strobing and fading effects can be produced by the fixture Prism A three segment prism allows beam splitting effects The prism can be independently inserted in the beam path o...

Страница 25: ...out This is the default setting Hold sets the fixture to continue obeying the last DMX values it received If no DMX signal was being received the fixture will black out Preset Scene sets the fixture t...

Страница 26: ...functions MODE ESC Activate the menus or go back one level towards the top of the menu UP Scroll up or increase a number DOWN Scroll down or reduce a number ENTER Activate the control panel if it is i...

Страница 27: ...ure Settings Lock Set Passcode option If you do not set a custom code the default code is 0000 Manual Control Using the Manual Control menu you can set fixed values to the fixture s control channels a...

Страница 28: ...tion settings using the Service Service Advanced Save Settings menu and load them using the Load Settings Preset 1 2 3 options These allow you to quickly set up the fixture in a particular configurati...

Страница 29: ...ne Press ENTER to capture scene Store scene for no signal PWM 600 Hz 2200 Hz 3000 Hz 4800 Hz 9600 Hz 25000 Hz Frequency of LED dimming Display Mode Auto On Off Display blanking Display Orientation Nor...

Страница 30: ...otal User Shows power cycles Power Hours LED Hours DMX Link Status Refresh Rate Hz Frame Length Mode Length Details of DMX signal Temperatures xxx Unit temperatures Fan Speeds Fan1 Error Log Xxx SERVI...

Страница 31: ...isable Off On Units C F Offsets Tilt xxx Zoom xxx Reset Counter Power Hours Power Cycles LED Hours Max Temperature Temperature Unit Save Settings Preset 1 Preset 2 Preset 3 Factory Backup See Note 2 b...

Страница 32: ...Control of the three color wheels two gobo wheels gobo rotation zoom and the prism is provided You also have control of focus and a control settings channel that lets you configure the feature and ad...

Страница 33: ...m Cyan Full over fixed Colors to Open and back Slow Fast 216 255 84 7 100 0 6 Color 2 Magenta Position 1 Open 0 3 0 0 1 2 0 Snap Position 1 2 Split Color 4 7 1 6 2 7 Position 2 8 11 3 1 4 3 Position 2...

Страница 34: ...ng 165 176 64 7 69 0 Fade Gobo wheel spin stop 177 177 69 4 69 4 Gobo wheel spin clockwise fast slow 178 216 69 8 84 7 Gobo wheel spin stop 217 217 85 1 85 1 Fade Gobo wheel spin counterclockwise slow...

Страница 35: ...ables EXO Beam 10 User Manual Rev A 35 Gobo wheel spin stop 185 185 72 5 72 5 Snap Gobo wheel spin clockwise fast slow 186 219 72 9 85 9 Fade Gobo wheel spin stop 220 220 86 3 86 3 Snap Gobo wheel spi...

Страница 36: ...0 3 0 1 2 Fade Variable position from 0 360 4 127 1 6 49 8 Rotation stop 128 128 50 2 50 2 Rotation clockwise fast slow 129 191 50 6 74 9 Rotation stop 192 192 75 3 75 3 Rotation counterclockwise slow...

Страница 37: ...95 74 5 76 5 PWM 2200 Hz 5s hold 196 201 76 9 78 8 PWM 3000 Hz 5s hold 202 207 79 2 81 2 PWM 4800 Hz 5s hold 208 213 81 6 83 5 PWM 9600 Hz 5s hold 214 219 83 9 85 9 PWM 25 kHz 5s hold 220 225 86 3 88...

Страница 38: ...display on the back of the fixture as you may scratch these surfaces Use the tilt lock mechanism to hold the head in a vertical position for easier cleaning GLP Service and Support Contact informatio...

Страница 39: ...stible materials 0 5 m 20 in Minimum distance to illuminated surfaces 0 5 m 20 in Installation environment Temporary or permanent indoor installation temporary outdoor installation Secondary attachmen...

Страница 40: ...fications 40 EXO Spot 30 User Manual Rev A Included items Power cable with Neutrik powerCON TRUE1 mains input plug Dimensions and weight Length 368mm 14 5 ins Width 380 mm 15 0 ins Height 605 mm 23 8...

Страница 41: ...German Light Products Dimensions EXO Beam 10 User Manual Rev A 41 15 Dimensions All dimensions are in millimeters...

Страница 42: ......

Страница 43: ......

Отзывы: