Assembly and connection
page 8/20
Operating Instructions Force 120
2018-03-02
6 Assembly and connection
6.1 Set up device
The device can be operated standing and hanging. With safety factor 12, a maximum of two devices can be
operated among each other.
Attention
High air flows. Objects in the area can be damaged or damage the Force 120.
■
Make sure that there are no light, unsecured objects up to 3 meters in front of and
behind the device.
Stationary
Condition(s)
■
The installation site has sufficient carrying capacity (at least 100 kg).
1. Place the device on the ground with the rubber feet.
2. Orient the device so that the front is clearly visible.
3. Secure the device with safety ropes.
✓
The device is set up and can be connected.
Hanging
1. Attach the brackets to the D-Rings.
2. Secure the device with safety ropes.
✓
The device is suspended and can be connected.
6.2 Connect the device
Connection panel
Fuse
T10A 220V
DMX In
Mains In
DMX Out
Image 2: Connection panel
Fuse:
Fuse holder
DMX in:
DMX input (5-pin)
Mains in:
Input PowerCON True1
DMX out:
DMX output (5-pin)
Connect the device
Conditions
■
The device is set. (
see chapter 6.1
)
1. To establish the signal connection, connect the device and other devices or the controller with a DMX
cable. Therefore plug in the DMX cable
DMX in
and
DMX out
.
2. Plug in the PowerCON True1 cable into the PowerCON True1 input
Mains in
of the device.
3. Plug in the plug of the PowerCON True1 cable into a socket.
✓
The device is now connected and ready for use.