Boiler Safety Devices

Boiler Shutdown

The boiler software is designed to recognise the potential for

an overheat lockout and will shutdown before this happens.

To restart the boiler, press the reset button, see diagram 2.

If the boiler fails to resume normal operation and all external

controls are calling for heat, then call your Installation/Servicing

company or Glow-worm service.

Frost Protection

With the gas and electric supplies ON and irrespective of any

room thermostat setting, the integral frost protection device

will operate the pump 

when the temperature of the boiler

water falls below 8

O

C.

The pump will stop after 10 minutes if the temperature is

higher than 10

O

C or has already reached 35

O

C.

The burner will only activate if the boiler temperature does not

reach 10

O

C after 30 minutes or at any time if the temperature

drops to 5

O

C.

The burner will switch off when the temperature reaches

35

O

C.

NOTE:

  Any other exposed areas of the system should be

protected by a separate frost thermostat.

Condensate Drain Blockage

As a safety feature the boiler will stop working if the condensate

drain becomes blocked.  During freezing conditions this may

be due to the forming of ice in the condense drain external to

the house.  Release an ice blockage by the use of warm cloths

on the pipe.  The boiler should then restart.  Contact your

Installation/Servicing company or Glow-worm service if the

fault persists.

Safety Discharge Valve

The safety discharge valve and discharge pipe is fitted to the

boiler.  This valve 

MUST

 

NOT

 be touched.  If there is any

discharge from the pipe,  switch off the boiler electrical supply,

then call your Installation/Servicing company or Glow-worm

service.

Содержание Ultracom sxi

Страница 1: ...www glow worm co uk 1 www glow worm co uk T o b e l e f t w i t h t h e u s e r Instructions for Use High Efficiency Condensing Boilers Ultracom sxi...

Страница 2: ...her on or off Open all doors and windows ventilate the area METAL PARTS This boiler contains metal parts components and care should be taken when handling and cleaning with particular regard to edges...

Страница 3: ...www glow worm co uk 3 13206 G C No 41 019 07 G C No 41 019 08 Ultracom 18sxi Ultracom 30sxi...

Страница 4: ...er Control Panel 9 Lighting the Boiler 10 Adjusting Temperature 11 Fault Finding 11 These instructions are an integral part of the boiler and must to comply with the current issue of the Gas Safety In...

Страница 5: ...ation is made to the boiler unless approved in writing by Glow worm Any alteration not approved by Glow worm could invalidate the certification boiler warranty and may also infringe the current issue...

Страница 6: ...t the boiler operates automatically Pluming from flue terminal Like all condensing boilers it will produce a plume of condensation from the flue terminal in cool weather This is due to the high effici...

Страница 7: ...tivate if the boiler temperature does not reach 10 O C after 30 minutes or at any time if the temperature drops to 5 O C The burner will switch off when the temperature reaches 35 O C NOTE Any other e...

Страница 8: ...solvent cleaner as you may damage the paintwork Servicing Maintenance and Spare Parts Frost Protection If the mains electricity and gas services are to be turned off for any long periods during severe...

Страница 9: ...ith symbols the status of the boiler refer to diagram 2 Diagram 2 13473 Control Panel MODE PROG SYMBOLS DISPLAYED ON THE LCD AND DESCRIPTIONS System Pressure Max burner display Min burner display Temp...

Страница 10: ...ols switch on the electrical supply to the boiler Lighting the Boiler 2 Select your required function refer to diagram 2 press Mode repeatedly to scroll through your options and select one of the foll...

Страница 11: ...F and code number press the reset button on the control panel see diagram 2 If the display shows a flashing pressure of 0 4bar or less then the system will need to be pressurised If this or any fault...

Страница 12: ...low worm co uk 12 Because of our constant endeavour for improvement details may vary slightly from those shown in these instructions Glow worm Nottingham Road Belper Derbyshire DE56 1JT 0020020823 02...

Отзывы: