Undo the two nuts shown in diagram 8.5 which secure the main
gas manifold to the burner and remove the shakeproof washers,
disengage the lint arrester and then withdraw the main gas
manifold from the burner.
Clean the lint arrester as necessary.
Inspect the main burner injector for damage or blockage, clean
or replace as necessary using a small amount of approved
jointing compound, on the external thread.
Inspect the ignition lead for wear or damage, clean or replace
as necessary, see diagram 8.4.
Inspect the thermocouple for wear or damage, clean or replace
flue blockage safety device as necessary, see diagram 8.4.
Inspect the electrode for wear or damage, clean or replace flue
blockage safety device as necessary, see diagram 8.4.
Inspect the flue blockage safety device sensing tube filter for
damage or blockage, clean or replace as necessary, see
diagram 9.4.
8.4 Refitting Burner Assembly
When refitting the lint arrester make sure that the lug is fitted into
the slot on the burner support bracket, see diagram 8.5.
Position the pilot shield around the pilot tube, ignition lead and
thermocouple before replacing the pilot shield mounting bracket,
see diagram 8.3.
Loosely replace the gas valve control securing screws, see
diagram 8.2. Refit the two screws shown in diagram 8.1, which
locate the burner support to the combustion chamber extension.
Refit the lower sensing tube nut into the bulkhead connection.
Then fully tighten the gas valve securing screws.
Before replacing the burner and controls assembly into the
back boiler the following servicing should be carried out.
8.5 Cleaning Back Boiler Flueways
Remove the burner assembly as Section 8.3.
Undo the two screws securing the fire front sensing tube, if
fitted, and remove, see diagram 8.6.
Undo the two steel screws securing the flue collector assembly,
see diagram 8.7 and remove the flue collector assembly.
Undo the two stainless steel screws securing the diverter plate,
see diagram 8.8 and remove the diverter plate by sliding it
forward.
Lift out the flue baffle, see diagram 8.9.
Clean the back boiler flue ways with a suitable stiff brush.
Note. A sheet of paper placed in the back boiler combustion
chamber will help in collecting any debris.
To make sure that the flueways are clean, view with the aid of
a mirror or reflector.
8.6 Refitting Flue Collector Assembly and
Final Reassembly
When refitting the flue baffle make sure that the four corner lugs
fit correctly into the back boiler flueways, see diagram 8.9.
When refitting the diverter plate make sure that the plate is
correctly fitted into the guide channels as shown in diagram 8.8
and replace the two stainless steel securing screws.
Refit the flue collector assembly and if fitted the fire front
sensing tube. Refit the burner and controls assembly to the
back boiler.