Glow-worm 0010035896 Скачать руководство пользователя страница 5

Safety 1

0020300878_00 Energy

7

Operating instructions

5

1.3.5 Risk of death due to

explosive and flammable
materials

Do not use the product in
storage rooms that contain
explosive or flammable sub-
stances (such as petrol, pa-
per or paint).

1.3.6 Risk of death due to lack

of safety devices

A lack of safety devices (e.g.
expansion relief valve, expan-
sion vessel) can lead to poten-
tially fatal scalding and other in-
juries, e.g. due to explosions.

Ask a competent person
to explain how the safety
devices work and where they
are located.

1.3.7 Risk of death due to

changes
to the product or the
product environment

Never remove, bridge or
block the safety devices.

Do not tamper with any of the
safety devices.

Do not damage or remove
any tamper-proof seals on
components.

Do not make any changes:

The product itself

to the gas, supply air, water
and electricity supply lines

to the entire flue system

to the entire condensate
discharge system

to the expansion relief valve

to the drain pipework

to constructional condi-
tions that may affect the
operational reliability of the
product

1.3.8 Risk of injury and

material damage due to
maintenance and repairs
carried out incorrectly or
not carried out at all

Never attempt to carry out
maintenance work or repairs
on your product yourself.

Faults and damage should
be immediately rectified by a
competent person.

Adhere to the maintenance
intervals specified.

1.3.9 Risk of

corrosion damage due to
unsuitable combustion
and room air

Sprays, solvents, chlorinated
cleaning agents, paint, adhes-
ives, ammonia compounds,
dust or similar substances may
lead to corrosion on the product
and in the air/flue pipe.

Ensure that the combustion
air supply is always free of
fluorine, chlorine, sulphur,
dust, etc.

Содержание 0010035896

Страница 1: ...Operating instruc tions Energy7 Energy7 25c A H GB Energy7 30c A H GB Energy7 35c A H GB GB IE...

Страница 2: ...ing system pressure 10 4 4 Filling the heating installation 10 4 5 Setting the operating mode 11 4 6 Setting the domestic hot water temperature 11 4 7 Setting the heating flow temperature 11 4 8 Produ...

Страница 3: ...tallations and for do mestic hot water generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other install ation components complian...

Страница 4: ...d rooms that smell of gas If possible open doors and windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mains pl...

Страница 5: ...o not make any changes The product itself to the gas supply air water and electricity supply lines to the entire flue system to the entire condensate discharge system to the expansion relief valve to...

Страница 6: ...design instructions Do not fit the casing on the product yourself If you require cabinet type casing for the product consult an approved heating special ist company 1 3 11 Risk of material damage cau...

Страница 7: ...s in the UK and to en courage regular servicing to optimise safety efficiency and performance Benchmark is managed and promoted by the Heating and Hotwater Industry Council For more information visit...

Страница 8: ...r ective 92 42 EEC Type Xx3 x Permissible flue gas connec tions PMS Maximum water pressure in heating mode PMW Maximum water pressure in domestic hot water mode V Hz Electrical connection W Max electr...

Страница 9: ...mode Permanently on Heating mode activated Flashing Burner on in heating mode Display flashing Switching on the product Fault Setting confirmed Fault in the product Appears instead of the basic displa...

Страница 10: ...ressure of the heating installa tion and the operating mode are shown in the display s basic display To return to the basic display Wait more than five seconds without pressing any buttons If a fault...

Страница 11: ...until the display shows the required operating mode Symbol Operating mode Heating domestic hot wa ter Heating only Domestic hot water only No requirement 4 6 Setting the domestic hot water temperatur...

Страница 12: ...ot function without problems after the checks have been carried out using the table con tact your competent person to rectify the problem 5 2 Fault codes in the display Fault codes have priority over...

Страница 13: ...s labelled with this mark In this case do not dispose of the product with the household waste Instead hand in the product to a collec tion centre for waste electrical or elec tronic equipment If the p...

Страница 14: ...e fuse in the building The product switches on automat ically when mains voltage is re stored The product is switched off Switch on the product The heating flow temperature is set too low or to the He...

Страница 15: ...e fault persists and you have pressed the reset button once more a burner anti cycling time of 45 minutes is auto matically activated The display shows S 54 If the fault persists consult a competent p...

Страница 16: ...9 Technical helpline 0330 100 7679 After sales service 0330 100 3142 www glow worm co uk 0020300878_00 02 03 2020 These instructions or parts thereof are protected by copyright and may be reproduced o...