20
G
B
5 Assembly
5.1
Figures
–
6 Commissioning
Before putting into operation, observe Chapter 2 “For your safety”.
Health risk through leaking cleaning fluid! A leaking device or leaking
components may result in draining or spouting of cleaning fluid. For this reason, observe the
following safety instructions:
Prior to each use, check the device to ensure fault-free condition and leak-tightness.
To perform the leak test, fill the container with water! Pull up the safety / pressure relief
valve (K) by hand and check that it returns to the starting position.
Only operate or move device when standing upright. Do not tilt to one side or hold upside down.
Inspect all screw joints for tight fitting.
6.1 Fill the tank
6.1.1 Check the safety valve
>>
Figures
–
6.1.2 Vent the tank, drain the water & fill with foaming agent
Figures
–
Pull the safety / vent valve on the piston gauge with integrated safety valve (K) until the
device is depressurised.
>>
Figure
Prior to filling the foaming device, observe the instructions relating to particular hazards
(R-phrases / German Hazardous Substances Ordinance [GefStoffV]) and safety advice (S-
phrases / German Hazardous Substance Ordinance [GefStoffV]) provided on the chemical
containers according to the regulations.
Observe the max. fill level (see technical data). The regulations of the foaming agent
manufacturer specify the correct dosage and concentration.
6.2 Changing foam cartridges and spraying results >>
Figure
Work with the blue foam cartridge
(G2)
when using the GLORIA Green Growth Remover, the
GLORIA Basic Stone Cleaner and the GLORIA Wood / WPC Cleaner.
6.3 Applying pressure and spraying >>
Figures
–
You may be exposed to hazards that could injure you when handling the
device and the foaming agents. You must therefore always comply with the safety instruc-
tions / safety measures in this user manual, as well as the following instructions:
The device must only be operated when suspended in a vertical or steep upright position.
Pressing the actuation lever down on the quick closure valve initiates the spraying process.
This can be interrupted immediately by releasing the actuation lever.
3
1
6
4
9
7
7
10
14
11
NOTE!
CAUTION
WARNING
DANGER
RZ_FM 30_1018.qxp_Text_GB 25.10.18 09:55 Seite 20
Содержание FoamMaster FM 30
Страница 2: ...A J I K L E D F G C B M H RZ_FM 30_1018 qxp_Umschlag1 30 10 18 14 22 Seite 3...
Страница 3: ...1 7 1 2 1 2 1 3 4 max 3l 1 2 6 8 3 5 2 RZ_FM 30_1018 qxp_Umschlag2 30 10 18 14 22 Seite 3...
Страница 5: ...19 20 17 1 2 3 15 18 16 1 3 5 2 4 21 22 RZ_FM 30_1018 qxp_Umschlag 4 30 10 18 14 23 Seite 3...
Страница 91: ...91 GR 1 2 1 3 1 4 FM30 1 2 3 4 G1 G3 4 RZ_FM 30_1018 qxp_Text_GR 25 10 18 10 05 Seite 91...
Страница 92: ...92 GR 1 5 40 C 1 6 1 7 2 2 1 RZ_FM 30_1018 qxp_Text_GR 25 10 18 10 05 Seite 92...
Страница 93: ...93 GR 16 16 40 C K 3 bar 2 100 500 DGUV GLORIA GLORIA 10 6 RZ_FM 30_1018 qxp_Text_GR 25 10 18 10 05 Seite 93...
Страница 94: ...94 GR 2 2 1907 2006 2 3 Solvents Gasoline Oil RZ_FM 30_1018 qxp_Text_GR 25 10 18 10 05 Seite 94...
Страница 108: ...108 1 2 1 3 1 4 FM30 1 2 3 4 G1 G3 4 RU RZ_FM 30_1018 qxp_Text_RU 25 10 18 10 07 Seite 108...
Страница 109: ...109 1 5 40 C 1 6 1 7 2 2 1 RU RZ_FM 30_1018 qxp_Text_RU 25 10 18 10 07 Seite 109...
Страница 111: ...111 1907 2006 2 3 3 3 1 2 A B 1 C 2 D E F G H I G1 G3 J K L M N 1 RU RZ_FM 30_1018 qxp_Text_RU 30 10 18 14 32 Seite 111...