ECO Spot 2500 User Manual
Copyright © 2012 Globus New Media LLC
Page 3
Controls
Power on/off. The power switch sits next to the Power Cable. Once powered on,
the lamp needs a few minutes to reach full brightness, repeatedly turning the
projector on/off during this period will reduce the bulb life.
Discharge Lamp / Re-Start
Dimmer switch. The dimmer switch next to the Lamp Cable will only operate after
the light bulb reaches full brightness. Switch it to the ON position to reduce the
brightness to approx. 50%
An optional DMX module is available for controlling power on/off and dimming
(see chapter “DMX Module”).
Once powered on, the lamp needs a few minutes to reach full brightness,
repeatedly turning the projector on/off during this period will reduce the bulb life.
The standard version of the ES-2500 uses cold restrike technology. This requires the
lamp to cool off after use before it will turn on again. After turning off the projector,
it may take around 20 minutes to restart.
Discharge bulbs should be replaced before the end of their specified bulb life. The
integrated hour counter is used as reference to determine the time that the bulb
has been in use. It cannot be reset.