8 ·
· 9
MANUAL | VA1X | ATEX certified
MANUAL | VA1X | ATEX certified
Operation
WARNING - Injury hazard
Wear eye protection: Air stream from product may contain solid or liquid materials that
can result in eye or skin damage.
Failure to follow these instructions can result in serious injury or property damage.
Wear hearing protection: The noice level from the air motor may exceed 85 db (A)
Do not use combustible gases to drive this air motor
WARNING: POTENTIAL ELECTROSTATIC CHARGING HAZARD
Before use clean only with damp cloth.
Correct operation is your responsibility!
Make sure you have the proper operation conditions.
»
Check all connections before starting the air
motor. It is your responsibility to operate this
product at recommended speeds, loads and
ambient temperatures (-20°C to +60°C)
»
Check if the airline filtration and airline
lubrication is OK. The airline filter should be
drained and/or cleaned regularly and the
filter element examined for signs of clogging.
»
The maximum working pressure is 7 bar (100
PSI).
»
Clean surface of air motor unit thoroughly of
all dustproofing products, contaminants and
other impurities. Clean only with damp cloth.
»
Do not run the air motor at high speeds with
no load. This will result in excessive internal
heat that may cause motor damage.
»
The starting torque is less than the running
torque. The starting torque will vary depen-
ding on the position of the vanes in relation
to the air intake port when the motor is being
started.
»
During operation be aware if unfamiliar
sounds or vibrations occur. Stop the unit
immediately and investigate the source.
»
In case that the motor is exposed to high
vibrations, during operation and when not
Do not run the air motor at high speeds with no load.
This will result in excessive internal heat that may cause motor
damage.
STOP
Air motor
V1
V2
V4
V6
V8
V10
V12
LBF
4
90
40
70
140
400
157
N
18
400
170
300
620
1.750
700
»
Axial loads must be kept to a minimum.
»
Max. radial load midway along shaft as shown in graph below:
»
Check intake filter and silencer after the first 100 hours of operation.
»
Clean filters and determine how frequently filters should be checked during future operation.
in operation, please contact the manufactu-
rer. High vibrations might lead to increased
inspection interval of the bearings.
»
The motor may run continuously at speeds up
to the rated running conditions shown in our
performance data sheets. In these sheets the
output power/torque is based on running
conditions with the actual pressure measu-
red at the motor port. A silencer is supplied
together with the motor, but is not installed
»
Advisable is to use an air dryer with set point
of 20 degrees Celsius below lowest ambient
temperature.