Globe GSP18G Скачать руководство пользователя страница 8

Page 8

Operating Instructions

Operating the Stock Pot - Pilot Lighting Instructions

BEFORE OPERATING THE STOCK POT, IT SHOULD BE CHECKED TO SEE THAT IT IS SITTING 

LEVEL. IF THE STOCK POT IS NOT LEVEL, PERSONAL INJURY CAN OCCUR.

Adjust the feet to level the Stock Pot. Be sure the catch tray has been properly placed.
The pilot light on the appliance has been set at the factory. Each burner has a pilot light.

1.  Make sure all knobs are in the “ OFF ” position.

2.  The main gas valve should be “CLOSED/OFF” for five (5) minutes prior to lighting pilots to clear

 

  

any existing gas.

3.  Turn the main gas valve that supplies the gas to the stock pot to “ON/OPEN”.
  

NOTE: Each burner is equipped with its own pilot. Once the main gas valve is open, gas will flow

 

  

to both pilots. It will be necessary, to lite both pilots even if only one burner will be used during  

  

cooking.

4.  Light and hold an ignition source (match) at the pilot. When the flame is established, remove the

 

  

ignition source. Repeat this step for each burner as each burner has its own individual pilot.

5.  Turn each burner knob to “ON”. If the burners do not ignite promptly, turn the knobs to the “OFF” position. 

  

From the opening in the front panel, use a screwdriver and turn the pilot valve screw counterclockwise  

  

which will increase the flame height, and then repeat step 4.

  

If the pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot flame

 

  

should be as small as possible, but large enough to guarantee reliable ignition of the burners when the 

  

knobs are turned to “ON”. The holes located in the front panel are pilot valve adjustments. Use a 

  

screwdriver to turn the valve to adjust the flame height to your desired level.

Igniting the Burner

T

o ignite the burner, turn knob to the “ON” position. Then back set to the desired flame level. The range of 

adjustment is virtually infinite between “ON” and “OFF”. 

The space between the legs at the bottom admits combustion air. DO NOT BLOCK THIS SPACE.

All burners are lit from constantly burning pilots. Turning the valve to the desired flame height is all that is required 

to put the unit in service.
Do not permit fans to blow directly at the unit. Wherever possible, avoid open windows next to the unit’s sides or 

back. Avoid wall type fans which create air cross-currents within a room.

It is also necessary that sufficient air be allowed to enter the room to compensate for the amount of air removed 

by any ventilating system. Otherwise, a subnormal atmospheric pressure will occur, affecting operation and 

causing undesirable working conditions.
A properly designed and installed hood will act as the heart of the ventilating system for the room or area in which 

the unit is installed, and will leave the unit independent of changing draft conditions.
NOTE: It may be necessary to adjust the balance of gas, volume and air supply to each burner. This must be done 

by an authorized service technician.

TO AVOID SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE:

• 

NEVER 

move the stock pot when stock pot is turned on or connected to main gas supply line.

• 

ALWAYS 

remove cooking pot from top of the stock pot before moving. 

 1. 

If it is necessary to move the stock pot, make sure all knobs are in the “OFF” position.

 2. 

Remove cooking pot from the stock pot.

 3.  Close the main gas valve and disconnect stock pot from the main gas valve. 

Содержание GSP18G

Страница 1: ...oppers Scales This manual contains important safety instructions which must be strictly followed when using this equipment IMPORTANT SAFETY NOTICE WARRANTY REGISTRATION SCAN THE QR CODE WITH YOUR MOBI...

Страница 2: ......

Страница 3: ...RYDEN RD DAYTON OH 45439 PHONE 937 299 5493 TOLL FREE 800 347 5423 FAX 937 299 4147 E MAIL info globefoodequip com WEBSITE www globefoodequip com Globe Food Equipment Company 2017 2022017 980180 Ver 1...

Страница 4: ...ersonnel come in contact with this equipment Please remember that Globe cannot anticipate every circumstance or environment in which this equipment will be operated It is the responsibility of the own...

Страница 5: ...ANSI Z223 1 NFPA 54 the National Gas Installation Code CSA B149 1 or the Propane Installation Code CSA B149 2 as applicable and in accordance with local codes The appliance and its individual shutoff...

Страница 6: ...0 for L P 7 THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON COMBUSTIBLE SURFACES ONLY Combustible clearances 18 sides 45 cm 18 rear 45 cm 8 Do not obstruct the flow of combustion and ventilation air...

Страница 7: ...cing or adjusting any parts or attachments and before cleaning Never tip the stock pot Never leave the stock pot on overnight Do not operate any equipment with a damaged or leaking gas line ignitor or...

Страница 8: ...he front panel are pilot valve adjustments Use a screwdriver to turn the valve to adjust the flame height to your desired level Igniting the Burner To ignite the burner turn knob to the ON position Th...

Страница 9: ...with a soft cloth Daily Controls Unit should be turned off when not in use It is recommended that the unit be disconnected from the gas supply by closing the main gas valve Use a clean cloth to wipe d...

Страница 10: ...rea Main gas line leak Turn off main gas valve DO NOT LIGHT FLAME ignite anything or turn switch on anything electrical Call fire department if needed and call for service Cooking surface heating up s...

Страница 11: ......

Страница 12: ...ESS OR PROFITS OR OTHER ECONOMIC LOSSES OR STATUTORY OR EXEMPLARY DAMAGES WHETHER IN NEGLIGENCE WARRANTY STRICT LIABILITY OR OTHERWISE This warranty is given only to the first purchaser from a retail...

Отзывы: