This device complies with Part 15 of the FCC Rules. Operation is subject to the following 

two conditions: (1) this device may not cause harmful interference, and (2) this devised 

must accept any interference received, including interference that may cause undesired 

operation.  Changes  or  modifications  not  expressly  approved  by  the  party  responsible 

for compliance could void the user’s authority to operate the equipment. NOTE: This 

equipment has been tested and has been found to comply with the limits for a Class 

B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to 

provide reasonable protection against harmful interference in a residential installation. 

This equipment generates uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not occur 

in a particular installation. If this equipment does cause harmful interference to radio or 

television reception, which can be determined by turning the equipment off and on, 

the user is encouraged to try to correct the interference by one or more of the following 

measures:
• Reorient or relocate the receiving antenna

• Increase the separation between the equipment and receiver

• Connect the equipment into an outlet on a circuit different from that to which the receiver 

is connected.

• Consult the dealer or an experienced radio/TV technician for help.

FCC STATEMENT

6. Refrain from operating the device if it has been damaged.
7. Do not use the product if there is any sign of battery leakage as it may cause damage 

to the wand.

8. Allows allow the product to cool down completely before storing. When not in use, 

remove batteries and store in provided travel bag. Store in a safe place, out of reach 

of children.

DANGER

DO NOT ALLOW THIS PRODUCT TO BE EXPOSED TO WATER OR ANY OTHER TYPE 

OF LIQUID OR EXCESSIVE MOISTURE.

DANGER

Always direct the UV-C light AWAY from the eyes 

ans skin. Direct prolonged exposure of eyes or skin 

to The UV-C light bulb can cause serious skin burn 

and eye  inflammation from short  wave  ultraviolet 

radiation. Radiation from these lamps is harmful to 

the eyes and skin.

DANGER

Application of UV-C light to existing mold growth 

can  cause  respiratory  irritation  and  allergic 

symptoms.  Do  not  use  UV-C  light  where  active 

mold  growth  exists.  Remove  active  mold  growth 

from surfaces prior to exposure.

POTENTIAL MOLD

SPORE RELEASE

Содержание 66461

Страница 1: ... encounter any difficulties have any questions or simply wish to offer us your valuable feedback you may contact us in the following ways Toll Free Telephone 1 888 543 1388 North America Only Toll Free Fax 1 800 668 4562 North America Only E Mail info globe electric com Mail Globe Electric Customer Service Department 150 Oneida Montreal Quebec Canada H9R 1A8 Please visit our website to discover ot...

Страница 2: ...as a wavelength shorter than that of visible light and is generally subdivided into UV A UV B and UV C While Near UV is not technically within the ultraviolet spectrum it shares certain useful germicidal properties Short wave ultraviolet light such as UV C 100nm to 280nm damages DNA and disinfects surfaces with which it comes into contact Fortunately for us the sun s UV C light is absorbed by the ...

Страница 3: ...to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC STATEMENT 6 Refrain from operating the device i...

Страница 4: ... Ave Norwalk CA 90650 www globe electric com CAN ICES 005 B CAN NMB 005 B TECHNICAL DATA 1 Model 66461 2 UV C Quartz wave Technology 254nm 3 Power 2 5W 4 Life Span 10 000 hours 5 Built in gravity sensor 6 Travel Bag 7 ON OFF Button 8 Micro USB Cable Included 100CM 39in UV Tube Micro USB Cable Travel Bag Power ON OFF Power on LED Battery Cover Micro USB Plug DIMENSIONS OF ITEM 9 45 x 1 34 x 0 59 24...

Страница 5: ...ned at the given distance and time A Optimal Use For maximum disinfection over 99 the light should be held at 0 5 1 25cm away from the surface for 10 seconds for bacteria or 50 seconds for influenza B Optional Use recommended for bacteria only When the light is held at 2 5cm for 25 seconds the percentage of antibacterial neutralization should reach over 97 depending on the surface conditions WARNI...

Страница 6: ...efer to the BATTERY INSTALLATION section of this manual SAFETY FEATURES 1 To avoid the eyes from being exposed to the UV light the wand is designed with a built in gravity sensor that will automatically turn off the light when the wand is tilted more than 90 degrees to the left or the right This feature permits the light to only turn on when it is facing downward OPERATING DIRECTIONS 2 To prevent ...

Страница 7: ... over the item surface at 0 5 to 2 1 25 to 5cm for 10 seconds or the required time to reach the level of desired disinfection 5 Carefully repeat process until the complete item surface has been exposed to the UV light at the maintained distance and time 6 Once you have completed disinfecting the area press the Power On Off button to quickly turn off the power of the device OPERATING DIRECTIONS You...

Страница 8: ...e shall be no liability on the part of Globe for any special indirect incidental or consequential damages including but not limited to any loss of business or profits whether foreseeable or not Some jurisdictions may not all the exclusion of incidental consequential damages so the above limitation or exclusion may not apply to you For warranty related issues please contact Globe Electric Customer ...

Страница 9: ... se describe anteriormente no será responsabilidad de parte de Globe por ningún daño especial indirecto incidental o consecuente entre otros cualquier pérdida de negocios o ingresos ya sea previsible o no Algunas jurisdicciones podrían no permitir la exclusión de daños incidentales o consecuentes de manera que la limitación o exclusión anterior podría no ser aplicable a usted Para asuntos relacion...

Страница 10: ...impias sin mugre polvo y otros materiales que impedirían que los gérmenes queden expuestos directamente a la luz UV C 1 Despliegue la barra y dirija la fuente de luz hacia abajo y lejos del cuerpo y los ojos 2 Presione el botón de encendido apagado del dispositivo y mantenga así 3 segundos hasta que se ilumine la luz indicadora azul 3 Una vez que la luz esté encendida y dirigida hacia abajo comien...

Страница 11: ...terías consulte la sección INSTALACIÓN DE LAS BATERÍAS en este manual CARACTERÍSTICAS DE SEGURIDAD 1 Para evitar que los ojos se expongan a la luz UV la barra tiene un sensor de gravedad integrado que apagará la luz cuando la barra se incline más de 90 grados a la izquierda o a la derecha Esta función permite que la luz se encienda solamente cuando esté dirigida hacia abajo INSTRUCCIONES DE OPERAC...

Страница 12: ...indicados A Uso óptimo Si quiere máxima desinfección más del 99 debe mantener la luz a 1 25 cm 0 5 in de la superficie durante 10 segundos para eliminar bacterias o 50 segundos para eliminar el virus de la gripe B Uso opcional recomendado únicamente para eliminar bacterias Cuando la luz se mantiene a una distancia de 5 cm 2 in durante 25 segundos el porcentaje de neutralización de bacterias alcanz...

Страница 13: ...c com CAN ICES 005 B CAN NMB 005 B DATOS TÉCNICOS DIMENSIONES DEL PRODUCTO 9 45 x 1 34 x 0 59 24cm x 3 40cm x 1 50cm 1 Modelo 66461 2 Tecnología de onda de cuarzo UV C 254 nm 3 Energía 2 5 W 4 Vida útil 10 000 horas 5 Sensor de gravedad integrado 6 Bolsa de transporte 7 Botón de encendido apagado 8 Micro USB incluido 100CM 39in Tubo UV Cable Micro USB Bolsa de transporte Botón de encendido apagado...

Страница 14: ...ir la interferencia mediante una o más de las siguientes medidas Reoriente o reubique la antena receptora Aumente la separación entre el equipo y el receptor Conecte el equipo en una toma de corriente de un circuito diferente al que el receptor está conectado Consulte al distribuidor o a un técnico experimentado en radio o televisión para recibir ayuda DECLARACIÓN 6 Absténgase de usar el dispositi...

Страница 15: ...isible para el ojo humano llamado ultravioleta La luz ultravioleta tiene una longitud de onda más corta que la luz visible y en general se subdivide en UV A UV B y UV C Aunque la UV cercana no está técnicamente dentro del espectro ultravioleta comparte ciertas propiedades germicidas útiles La luz ultravioleta de onda corta tal como la UV C 100 nm a 280 nm daña el ADN y desinfecta superficies con l...

Страница 16: ...una pregunta o simplemente desea ofrecernos sus valiosos comentarios puede ponerse en contacto con nosotros de las siguientes maneras Llamadas sin costo 1 888 543 1388 solo en Norteamérica Fax sin costo 1 800 668 4562 solo en Norteamérica Correo electrónico info globe electric com Correo postal Globe Electric Departamento de servicio al cliente 150 Oneida Montreal Quebec Canadá H9R 1A8 Visite nues...

Отзывы: