Страница 2: ...er Data Entry Pane 14 Status Pane 14 ESN Status Display Table 14 List ESN s Button 14 View Summary Button 15 Program Button 16 Toolbar 16 File Menu 16 Tools Menu 17 Help Menu 20 Getting Started Tab 20...

Страница 3: ...essage 64 Messaging Priority 65 Prioritization of Periodic Standard Message Report Rates 65 Message Priorities 66 Serial Commands 66 Serial Packet Format 66 CRC Algorithm 67 Serial Packet Types 68 Sen...

Страница 4: ...itch to battery power if line power input is lost C Connection Method 1 When using the Serial Input Cable connect the voltage supply positive to the VIOLET wire through a 1 Ampere Fuse The fuse should...

Страница 5: ...regular time intervals that are programmed during the configuration process Standard Messaging Mode can also be configured to utilize the SMARTONE s internal vibration sensor If enabled the SMARTONE...

Страница 6: ...tor owns 1 000 trailers When the trailer s are sitting at a depot they want a location message once a day They also want a message notification within 1 hour when a trailer has left a depot Lastly the...

Страница 7: ...t the construction company will need to set the Change of Location Area size of the job site the message interval while inside the Change of Location Area 1 per day the interval at which the SMARTONE...

Страница 8: ...nterval and or based on configurable multiples of accumulated hours and or number of counted events or hours of vibration Usage Example 1 A construction company needs weekly engine run times for their...

Страница 9: ...Location Message the SMARTONE will wake up at a scheduled interval or time of day and begins to acquire a GPS fix Once it receives its GPS fix it will transmit the location to the Globalstar Simplex S...

Страница 10: ...mer s back office application and converted into actionable data The SMARTONE will send each message 3 times to insure that the message has been received by the Globalstar Satellite Constellation Once...

Страница 11: ...vice On or Off remove the connector cover from the end of the device Then invert and replace the connector cover so that the word Off or On whichever is desired is visible See Appendix F Battery Insta...

Страница 12: ...eady to use with a factory configuration loaded in the device The factory configuration Standard Messaging without Motion and Interval Messaging of 12 hours may be changed using the SMARTONE Configura...

Страница 13: ...B Configuration Cable to Program Once the Program button has been depressed the Configuration Cable should not be disconnected if already connected from the device and or the computer The USB Configur...

Страница 14: ...ins a table with a list of devices connected to the PC their ESN s firmware version and COMM port assigned to each device as well as the execution buttons for configuring connected SMARTONE s ESN Stat...

Страница 15: ...readout of every user configurable parameter that exists for the SMARTONE View Summary Window The Menu Bar in the View Summary Window allows the user to either print the parameters or save the configu...

Страница 16: ...ndow asking for confirmation to restore all settings to their default This will not affect the settings stored inside the connected SMARTONE s The settings will only reset in the software display not...

Страница 17: ...time a device is successfully programmed the configuration will save that occurrence to a text log file The information stored is the ESN of the device the local time at which it was programmed and th...

Страница 18: ...ed SMARTONE message type 1 The hex character data in the text box below the command will be appended to the GPS data and sent Send Data w o GPS message causes the SMARTONE to send the first 8 bytes of...

Страница 19: ...w which allows the user to browse for a location and save the diagnostic information in a text file Test Vibration Sensor Button is used to find the minimum maximum and average vibration sensitivity d...

Страница 20: ...up a window with the SMARTONE Configuration version number Getting Started Tab The Getting Started Tab allows the user to select the Mode of operation for the SMARTONE The Modes include Standard Mess...

Страница 21: ...de is selected for basic tracking functionality on the SMARTONE The SMARTONE will automatically report its position at regular time intervals The messages sent in this Mode are called Location Message...

Страница 22: ...ion Area of configurable size around the device If the SMARTONE stays within its Change of Location Area the number of transmissions will be reduced When the SMARTONE leaves the Change of Location Are...

Страница 23: ...l specified by days hours and minutes The SMARTONE accepts a single interval only Once the interval has been entered in Days Hours and Minutes click the ADD button to accept the interval and add it to...

Страница 24: ...ual Rev 1 5 DOC 9100 0268 01 p 24 The REMOVE button deletes the selected time of day or interval from the message interval box The CLEAR button deletes all the time of days or interval in the message...

Страница 25: ...igured to send messages throughout the time the input is in the desired state either to opened or closed position The message interval while the input is active can be configured in Days Hours and Min...

Страница 26: ...SmartOne Manual Rev 1 5 DOC 9100 0268 01 p 26 the times in the Location Message Tab...

Страница 27: ...nge extends from 0 to 45 days in steps of a day The default is 1 day The SMARTONE will detect low battery conditions while at least 100 more messages can still be transmitted Interval for Diagnostic M...

Страница 28: ...n Message Interval while In Motion This parameter defines the transmission interval of location messages while SMARTONE is In Motion with a transmission rate between 5 to 65 000 minutes 45 Days The de...

Страница 29: ...ment Time to be in a State of Vibration Time the vibration sensor must be above the sensitivity level before being in a State of Vibration If the device senses continuous vibration for a period of tim...

Страница 30: ...rs and Minutes the ADD button will accept the interval and add it to the message interval box Message Time s of Day The SMARTONE can be configured to report at specific time s of day The message inter...

Страница 31: ...e message interval while the input is active can be configured in Days Hours and Minutes Once the input is de activated the SMARTONE will return to the message interval or time s of day for Location M...

Страница 32: ...SmartOne Manual Rev 1 5 DOC 9100 0268 01 p 32 Options Tab Device Turned On Message The SMARTONE can be configured to send or not send a Device Turned On Message on Power up The default is enabled...

Страница 33: ...tery conditions while at least 100 more messages can still be transmitted Interval for Diagnostic Message The SMARTONE can send a diagnostic message with information on the diagnostic status of the de...

Страница 34: ...hange of Location Area in days hours and minutes In the Reduced Messaging Mode the asset will send infrequent messages if asset is in its Change of Location Area Position Check Interval while in State...

Страница 35: ...nsor must be above the sensitivity level before being in a State of Vibration If the device senses continuous vibration for a period of time less than the specified in this parameter the device will i...

Страница 36: ...f Location Area The number of Change of Location Area Alert messages sent by the device is configurable with range from 0 to 3 The message interval of the Change of Location Area Alert message will be...

Страница 37: ...of the input s changed The SMARTONE can also send this message when it enters or exits the Vibration State Undesired State Message The SMARTONE can be configured to send messages throughout the time...

Страница 38: ...vents at configurable intervals specified in days hours and minutes Options Tab Device Turned On Message The SMARTONE can be configured to send or not send a Device Turned On Message on Power up The d...

Страница 39: ...diagnostic status of the device The diagnostic message includes battery status GPS average search time GPS fails and number of transmissions since last diagnostic message Transmit interval of diagnost...

Страница 40: ...nside its Change of Location Area while in Theft Recovery Mode Change of Location Range Change of Location Range specifies the length in meters kilometers yards or miles from the center of the Change...

Страница 41: ...ation to Globalstar Simples network It uses the information to confirm if it is inside its Change of Location Area Vibration Sensor Settings Button This button activates the Vibration Settings window...

Страница 42: ...1 to 3 The message interval of the Change of Location Area Alert message will be the same as the In Motion Message Interval outside the Change of Location Area In Motion Interval This parameter determ...

Страница 43: ...RTONE can be configured to send messages throughout the time the input in the desired state message either to opened or closed position The message interval while the input is active can be configured...

Страница 44: ...Message The SMARTONE can be configured to transmit a Replace Battery message based on a low battery condition Configuration range extends from 0 to 45 days in steps of a day The default is 1 day The...

Страница 45: ...total global types Types 0 and 3 are applicable to the function and features of the SMARTONE type 1 and 2 are user defined message types Type 0 Standard Message All of the various message types that...

Страница 46: ...priority message Bit 5 Missed Input 2 A value of 1 in this bit means that an input state change of Input 2 was missed due to the transmission of a higher priority message 0 GPS fail counter 2 Bit 7 6...

Страница 47: ...ion Value 0 Unit is not in a state of vibration 8 2D 1 Bit 5 Value 1 GPS data reported is from a 2D fix Only 3 satellites were used in the fix Value 0 GPS data reported is from a 3D fix 8 Motion 1 Bit...

Страница 48: ...ail counter Counts up to a maximum value of 3 upon GPS failure 1 2 3 4 5 6 Latitude Longitude 48 Byte 1 Latitude MSByte Byte 2 Latitude Byte 3 Latitude LSByte Byte 4 Longitude MSByte Byte 5 Longitude...

Страница 49: ...At Rest when the message was transmitted 8 Fix Confidence Bit 1 Bit 7 0 High confidence in GPS fix accuracy 1 Reduced confidence in GPS fix accuracy Table 2 Location Message Device Turned On Message T...

Страница 50: ...id not trigger change message 1 Triggered message Bit 1 Input 1 state 0 Closed 1 Open Bit 2 Input 2 change 0 Did not trigger message 1 Triggered message Bit 3 Input 2 state 0 Closed 1 Open 7 Standard...

Страница 51: ...of Location Area Alert Message is shown in Table 4 Byte Number Variable Bits Description 0 Type field 2 Bit 1 0 0 Standard message type 0 Battery state 1 Bit 2 0 Good battery 1 replace battery 0 GPS D...

Страница 52: ...message 8 RESERVED 3 Bits 2 0 RESERVED in SmartOne 8 Vibration triggered message 1 Bit 3 Value 1 This message is being sent because transmit on change of vibration state is selected and the vibration...

Страница 53: ...fields 0 Missed Input State Change 2 Bit 4 Missed Input 1 A value of 1 in this bit means that an input state change of Input 1 was missed due to the transmission of a higher priority message Bit 5 Mi...

Страница 54: ...bit 1 Bit 4 Value 1 Unit is in a state of vibration Value 0 Unit is not in a state of vibration 8 2D 1 Bit 5 Value 1 GPS data reported is from a 2D fix Only 3 satellites were used in the fix Value 0...

Страница 55: ...as missed due to the transmission of a higher priority message 0 GPS fail counter 2 Bit 7 6 GPS fail counter Counts up to a maximum value of 3 upon GPS failure 1 2 3 4 5 6 Latitude Longitude 48 Byte 1...

Страница 56: ...e 0 Device was At Rest when the message was transmitted 8 Fix Confidence Bit 1 Bit 7 0 High confidence in GPS fix accuracy 1 Reduced confidence in GPS fix accuracy Table 6 Undesired Input State Messag...

Страница 57: ...atus Changed message Bit 0 Input 1 change 0 Did not trigger message 1 Triggered message Bit 1 Input 1 state 0 Closed 1 Open Bit 2 Input 2 change 0 Did not trigger message 1 Triggered message Bit 3 Inp...

Страница 58: ...er data Latitude Longitude 48 Byte 1 Latitude MSByte Byte 2 Latitude Byte 3 Latitude LSByte Byte 4 Longitude MSByte Byte 5 Longitude Byte 6 Longitude LSByte 360 degrees of longitude coded in signed bi...

Страница 59: ...degrees of longitude coded in signed binary with 3 bytes and 180 degrees of latitude coded in signed binary with 3 bytes Positive longitude correspond to East Longitudes Positive Latitude correspond...

Страница 60: ...office as complete messages of a length longer than 9 bytes The SmartOne supports user defined messages Class 1 and 2 of up to 54 bytes Message type 2 shall be a Raw Payload message This message type...

Страница 61: ...andard message type 0 Subtype 6 Bit 7 2 21 for Diagnostic Message 1 Number of transmissions per burst 4 Bits 3 0 Number of Transmissions 1 to 15 Transmissions 1 Battery Condition 1 Bit 4 0 Good batter...

Страница 62: ...of Transmissions 1 to 15 Transmissions 1 Battery Condition 1 Bit 4 0 Good battery 1 Replace Battery 1 GPS Subsystem Fault 1 Bit 5 0 GPS system OK 1 Fault 1 Transmitter Subsystem Fault 1 Bit 6 0 Trans...

Страница 63: ...it 4 0 Good battery 1 Replace Battery 1 GPS Subsystem Fault 1 Bit 5 0 GPS system OK 1 Fault 1 Transmitter Subsystem Fault 1 Bit 6 0 Transmitter OK 1 Fault 1 Scheduler Subsystem Fault 1 Bit 7 0 OK 1 Fa...

Страница 64: ...s been in its undesired state with a resolution of 10 minutes For example 1 hour would be represented as a value of 6 2 hours as a value of 12 etc This resolution results in a rollover rate of a total...

Страница 65: ...ort Rates The SMARTONE supports several rates at which it will send a periodic standard message Periodic scheduled standard message rates are mutually exclusive This is the priority of the different r...

Страница 66: ...ged Device Turned On Normal Location In Motion or At Rest The two user defined message types actually have equal priority Either one will cancel the other one If for example the user interface command...

Страница 67: ...nt byte of the 16 bit CRC CRC Algorithm The Security Field is a 16 bit CRC of all of the previous fields including the preamble length and command bytes The remainder is initialized to all 1 s 0xFFFF...

Страница 68: ...rmation in a messaging burst Two bits are set in the on air message by the SmartOne informing the recipient that the message is the Truncated type The following table defines the message structure of...

Страница 69: ...1 The 22 and the 33 that the user sent are appended after the 6 bytes of latitude and longitude Send Raw Message serial message type 0x27 The SMARTONE will send raw user data using the Raw Payload com...

Страница 70: ...2 the remaining 6 bits make up the top 6 bits of the first byte sent in the serial command in this example 000100xx with the xx representing the two bits that the SmartOne forces to 10 A simple ACK or...

Страница 71: ...E can connect with devices that contain an asynchronous UART at 3 volt levels High State 2 7 3 Volts Low State 0 Volts Please contact Globalstar Support for more information CAUTION NEVER attempt to c...

Страница 72: ...tion of variables that control the operating performance of a tracker Sometimes referred to as the configuration Configure configuring Programming setting the variables that control the operation perf...

Страница 73: ...device that allows the detection of switch stage changes The inputs are dry contact inputs ON OFF Level of Sensitivity for Vibration Sensor a configurable parameter that sets the number of pulses per...

Страница 74: ...evel of Sensitivity for Vibration Sensor number for the time required to determine if a State of Vibration has ceased State of Vibration The vibration sensor is in a State of Vibration when the number...

Страница 75: ...l Rev 1 5 DOC 9100 0268 01 p 75 Appendix A Technical Support For technical support please contact Globalstar Inc corporate headquarters at 1 877 452 5782 or 1 905 712 7197 or by email customerservice...

Страница 76: ...used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or transm...

Страница 77: ...al apparatus complies with Canadian ICES 003 This device automatically adjusts its transmission frequency according to its location and is compliant with international regulatory requirements Changes...

Страница 78: ...sp cifique par l accord Foundation National des Sciences de Globalstar de 2001 Il est conforme avec CFR 25 213 Ce dispositif s ajuste automatiquement sur la fr quence de transmission selon son endroit...

Страница 79: ...sion Protection IP68 Freeze Thaw IP69K High Pressure Washing MIL STD 810F 95 to 100 Condensing Humidity MIL STD 810E Method 509 3 5 NaCl 95 Distilled Water Salt Fog SAE J1455 Random 20 Hz to 2000 Hz 0...

Страница 80: ...SmartOne Manual Rev 1 5 DOC 9100 0268 01 p 80 Appendix E Accessories SMARTONE Old External Inputs Cable Part 2030 0263 01 SMARTONE USB Configuration Cable Part 2030 0261 01...

Страница 81: ...SmartOne Manual Rev 1 5 DOC 9100 0268 01 p 81...

Страница 82: ...SmartOne Manual Rev 1 5 DOC 9100 0268 01 p 82...

Страница 83: ...SmartOne Manual Rev 1 5 DOC 9100 0268 01 p 83...

Страница 84: ...SmartOne Manual Rev 1 5 DOC 9100 0268 01 p 84 Appendix I Diagnostic Message Decoding...

Страница 85: ...SmartOne Manual Rev 1 5 DOC 9100 0268 01 p 85 Appendix J Accumulate Count Message Decoding...

Страница 86: ...that unused wires do not short to each other 4 All ground wires are common Therefore any ground can be used with any function Connector Pin COLOR FUNCTION 3 BROWN SETUP HANDSHAKE FROM SERIAL DEVICE 4...

Страница 87: ...ain that unused wires do not short to each other 3 All ground wires are common therefore any ground can be used with any function WIRING DIAGRAM Connector Pin COLOR FUNCTION 11 YELLOW SOFT POWER DOWN...