3
MENU 7 ENTER Load the previous setting.
MENU 8 n ENTER Setting device number (Device No), n = 0-32
Function Setting & Management application
:
Function Setting & Management application
:
This device could use command line to control via built in RS485 terminal program, (CLI
,
Command-Line
Interface), through RS485 terminal port (Console Port) for detailed function setup and management.
Use command as below
:
? Display
command
usage
* n
Control device number (Device No), n = 0-32, Without input parameter: Display the device number
Once the setting device into control mode, If you do not do any operation within 1 minutest, it will auto
off control mode.
# n
Control channel number (Channel No)
,
n = 1-8
,
Without input parameter: Display current setting
SET n
Setting this device number, n = 0-32, 0 mean stand alone mode (Factory Default)
Do not repeat setting the device number, recommend setting an individual connection to RS485, not to
connect other devices in series in order to avoid any confusion at the setting number.
STATUS n Display the current control device channel status
n = 0 display all channel status
n = 1-8 display the specified channel status
Without input parameter: Display current control channel status
AUTO
Setting auto gain mode (Factory Default)
MANUAL Setting manual Equalization mode.
LENGTH n
Manual setting Equalization mode for different cable distance (Sharpness), n = 0-63 (Factory Default is
0)
,
1 step equal 25 METERS. Without input parameter: Display current setting.
GAIN n
Manual setting Equalization mode for different gain control (Brightness), n = 0-63 (Factory Default is 32),
0 is the darkest value
,
63 is the brightness value. Without input parameter: Display current setting.
COLOR n Input video signal format
n = 0 is mono video signal
Termination
Resistors
32