SNOW STORM 

EVAPORATIVE SNOW

MACH INE

 T he Snow Storm

ww w.globalspecialeffects.

co

m

 

©2008 Global Special Effects, 

Inc. 

Содержание SNOW STORM

Страница 1: ...SNOWSTORM EVAPORATIVESNOW MACH INE The Snow Storm www globalspecialeffects com 2008 Global Special Effects Inc...

Страница 2: ...New and Improved Machine DMX WILL NOT WORK UNLESS TERMINATOR IS PLUGGED IN...

Страница 3: ...AD THE FOLLOWING BEFORE OPERATING THE SNOWSTORM The SNOWSTORM is an Electric Product not a Toy To avoid the risk of fire burns personal injury and electric shock it should not be played with and shoul...

Страница 4: ...Repeat Cycle Timer 5 min and 15 min cycles Specifications Voltage 110 60 Hz or 220v 220v 100v Current 20Amps Size 22 Wide 27 Long and 2 5 Tall without the yoke and C Clamp Weight 55 lbs Materials Pre...

Страница 5: ...the kind of water used will affect the quality of snow The recommended water to use is de ionized water This form of water has no minerals hard properties or chlorine De ionized water is the base ing...

Страница 6: ...contact Global Special Effects technical support at 1 256 229 5551 Chart 2 Approximate Rotary Switch or Dial Remote Settings Relative to Mounting Height to Minimize Residue RotarySwitch Setting or Rem...

Страница 7: ...itself from the solution container liquid 5 On the tethered remote a blinking light signifies that the Power is ON A constant light from the LED signifies that the SNOWSTORM is blowing evaporative sn...

Страница 8: ...Off On and Momentary The Mode dimmer will correspondtotheselected start address with the Cycle Time Duration and Flake Size channels in the following When the mode channel is set to one of the Momenta...

Страница 9: ...C Flake Size 6 7 X 0 1 6 7 X 1 2 6 7 X 2 3 6 7 X 3 4 6 7 X 4 5 6 7 X 5 6 6 7 X 6 7 6 7 X 7 8 6 7 X 8 9 6 7 X 9 10 Using the Controller Using the Controller Snow Machine Controller Table 2 5 Minute Cy...

Страница 10: ...tor to the 9 position while a DMX connection isbeingused There is a provision on the controller board for an additional fan control relay rated at 10 amps This relay has a completely separate power in...

Страница 11: ...SNOW STORM in a cool dry environment between 40 80 degrees F If electrical wires are frayed contact the factory at 256 229 5551 for service Never operate the SNOW STORMwith a frayed electrical wire Ca...

Страница 12: ...c No Recheck the DMX settings per the DMX settings in the manual The unit should always operate and blow snow with settings between 880 and 899 Contact customer service at 256 229 5551 or 256 229 555...

Страница 13: ...slippery surface Air flow and evaporative snow in your production design First all snow machines produce a cone of snow which is smallest near the machine and disperses as you get farther away creati...

Страница 14: ...s The first channel has four settings 0 63 Snow Machine is off 64 127 Allows for a 0 to 5 minute cycle time based on the settings of the 2nd channel This setting turns on the short internal timer circ...

Страница 15: ...FLUID IN 16 MINS 881 TO 889 24 MIN PER GALLON 871 TO 879 27 MIN PER GALLON 861 TO 869 30 MIN PER GALLON 851 TO 859 36 MIN PER GALLON 841 TO 849 48 MIN PER GALLON 831 TO 839 57 MIN PER GALLON 821 TO 82...

Страница 16: ...ot responsible for physical damage scratching or tube damage after shipping from Global Special Effects Manufacturing facility For safety reasons Global Special Effects will repair damaged electrical...